(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

MITSUBISHI PLC (Input/Output Units)

PLC (Input/Output Units) products in the Electrical & Controls category from MITSUBISHI. The product can be selected based on many product specifications such as Number Of Inputs, Input Format, Rated Input Voltage, Input answer time, Number of Outputs. MITSUBISHI offers products around 4 items and the product specifications can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies MITSUBISHI products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 10 Day(s) or Less
  • Others

4 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    CC-Link IE Field Network, Block Type Remote Unit Expansion Unit

    CC-Link IE Field Network, Block Type Remote Unit Expansion Unit

    MITSUBISHI

    [CC-Link IE Field Network, Block Type Remote Unit]
    ・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
    ・ You can easily add the number of input/output points by connecting expansion units
    ・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
    ・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
    ・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened

    Number Of Inputs Input Format Rated Input Voltage(V) Input answer time Number of Outputs Output Format Rated load voltage(V) Protection function Connection Terminal Representative Standard
    - - - - 16 Transistor / sync output 12$24 None Terminal Block -
    From: ₹ 21,010.96
    Days to Ship: 10 Day(s) or more
    day to ship 10 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    CC-Link IE Field Network Basic, Block Type Remote Unit

    CC-Link IE Field Network Basic, Block Type Remote Unit

    MITSUBISHI

    [CC-Link IE Field Network, Basic Block Type Remote Unit]
    ・ CC-Link IE field network Basic slave station. Input/output devices can be more easily distributed according to the equipment
    ・ It supported for CC-Link IE Field Network Basic diagnostic function. With the engineering tool, you can check for network abnormalities and input/output unit abnormalities
    ・ Parameters can be easily set with just a switch operation

    Number Of Inputs Input Format Rated Input Voltage(V) Input answer time Number of Outputs Output Format Rated load voltage(V) Protection function Connection Terminal Representative Standard
    - - - - - Relay contact output / Transistor / sync output 12 ~ 240 AC None Terminal Block CE / UL / CUL
    From: ₹ 42,687.94
    Days to Ship: 10 Day(s) or more
    day to ship 10 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series

    CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series

    MITSUBISHI

    [CC-Link IE Field Network, Block Type Remote Unit]
    ・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
    ・ You can easily add the number of input/output points by connecting expansion units
    ・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
    ・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
    ・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened

    Number Of Inputs Input Format Rated Input Voltage(V) Input answer time Number of Outputs Output Format Rated load voltage(V) Protection function Connection Terminal Representative Standard
    16 ~ 32 DC input 24 Less than 50 to 100 mS 16 Transistor / sync output 12/24 ~ 24 None Terminal Block -
    From: ₹ 28,030.39
    Days to Ship: 10 Day(s) or more
    day to ship 10 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    iQ-R Series Input/Output Unit

    iQ-R Series Input/Output Unit

    MITSUBISHI

    - I/O module, iQ-R series from MITSUBISHI.
    - Input/output rating is printed at the front, reducing incorrect wiring.
    - Easy-to-use cable tie hook for tidy wiring.
    - Existing 16-point terminal blocks are reusable, eliminating rewiring.
    - Simple confirmation by product serial no. printed on the front.
    - Alternating toggle switch used to display between 32-point LED signals.
    - Terminal signals are clearly labeled and color-coded.
    - Up to 32 LED signals clearly visible.

    Number Of Inputs Input Format Rated Input Voltage(V) Input answer time Number of Outputs Output Format Rated load voltage(V) Protection function Connection Terminal Representative Standard
    16 DC input DC5/12 Less than 50 to 100 mS - Transistor / source output 12/24 None Terminal Block CE / UL / CUL
    From: ₹ 18,153.96
    Days to Ship: 10 Day(s) or more
    day to ship 10 Day(s) or more
Brand
Product Series
From
Days to Ship
Number Of Inputs
Input Format
Rated Input Voltage(V)
Input answer time
Number of Outputs
Output Format
Rated load voltage(V)
Protection function
Connection Terminal
Representative Standard

You can add up to 6 items per a category to the compare list.

CC-Link IE Field Network, Block Type Remote Unit Expansion Unit

    You can add up to 6 items per a category to the compare list.

    CC-Link IE Field Network Basic, Block Type Remote Unit

      You can add up to 6 items per a category to the compare list.

      CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series

        You can add up to 6 items per a category to the compare list.

        iQ-R Series Input/Output Unit
          Brand

          MITSUBISHI

          MITSUBISHI

          MITSUBISHI

          MITSUBISHI

          Product Series

          CC-Link IE Field Network, Block Type Remote Unit Expansion Unit

          CC-Link IE Field Network Basic, Block Type Remote Unit

          CC-Link IE Field Network, Block Type Remote Unit NZ2GF Series

          iQ-R Series Input/Output Unit

          From

          ₹ 21,010.96

          ₹ 42,687.94-

          ₹ 28,030.39-

          ₹ 18,153.96-

          Days to Ship 10 Day(s) or more 10 Day(s) or more 10 Day(s) or more 10 Day(s) or more
          Number Of Inputs--16 ~ 3216
          Input Format--DC inputDC input
          Rated Input Voltage(V)--24DC5/12
          Input answer time--Less than 50 to 100 mSLess than 50 to 100 mS
          Number of Outputs16-16-
          Output FormatTransistor / sync outputRelay contact output / Transistor / sync outputTransistor / sync outputTransistor / source output
          Rated load voltage(V)12$2412 ~ 240 AC12/24 ~ 2412/24
          Protection functionNoneNoneNoneNone
          Connection TerminalTerminal BlockTerminal BlockTerminal BlockTerminal Block
          Representative Standard-CE / UL / CUL-CE / UL / CUL

          Loading...

          1. 1

          Related Categories to PLC (Input/Output Units)

          FAQ PLC (Input/Output Units)

          Question: What is a PLC (Programmable Logic Controller) and How Do Input/Output Units Function in Automated Systems?
          Answer: A PLC, or Programmable Logic Controller, is the brains behind many automated systems. It's like a specialized computer designed for controlling machines and processes. PLCs use Input/Output (I/O) units to communicate with sensors and actuators in the actual system. These I/O units serve as the interface between the digital world of the PLC and the physical world of your machines. Inputs gather data from sensors, while outputs send control signals to devices like motors and valves, allowing the PLC to make decisions and automate tasks.
          Question: How Do PLC Input/Output Units Interface with Devices and Sequencers in Industrial Automation?
          Answer: PLC I/O units interface with devices through wiring connections. Inputs are connected to sensors or switches, while outputs are linked to devices like motors, valves, or lights. The PLC's programming defines how inputs and outputs interact. For example, an input from a temperature sensor might trigger an output to turn on a cooling fan. PLCs can also work in sequence, performing a series of tasks based on inputs and previous outcomes. This sequence can be programmed to control complex industrial processes.
          Question: How Do I Install and Program PLC Input/Output Units for Optimized Control in Automated Machinery?
          Answer: Installing PLC I/O units involves mounting them in a control panel, connecting wires, and ensuring proper electrical connections. To program a PLC for optimized control, you'll use specialized software to create a logic program. This program defines how the PLC responds to different inputs and manages outputs. It's essential to understand your machinery's requirements, design a logical program, and thoroughly test it to ensure efficient and safe operation.
          Question: In Which Industrial Applications Are PLCs Commonly Used?
          Answer: PLCs are incredibly versatile and can be found in various industrial applications. They're widely used in manufacturing for tasks like assembly line control and quality assurance. They're also essential in processes like water treatment, energy production, and food production. Basically, anywhere automation and precise control are needed, you'll often find PLCs at the heart of the operation.
          X
          whatsapp-qr whatsapp-icon