MISUMI Control/Instrumentation Cables(Logarithm:18P)

MISUMI offers products Control/Instrumentation Cables specified by Logarithm 18P from Wiring Components product category. There are a total of 3 items. Equipment and parts for electrical systems, cables and electrical connections. MISUMI products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • Others

3 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    NA3VC UL Standard
    NA3VC UL Standard
    NA3VC UL Standard

    NA3VC UL Standard

    MISUMI

    300 V cable for fixed signals, ULAWM2517 standard compliant, with excellent oil resistance.

    • VW-1
    • ULAWM
    • Oil-Resistant
    • Strand Wire
    • Twisted Pair
    • 300 V
    Overall Length(m) Specified Length(m) Conductor Cross Section(mm2) AWG size(AWG) Number Of Cores(Core) Logarithm Finished outer diameter(mm) Rated Voltage Shield Properties Representative Standard Sheath (outer coating) color Grounding Wire Sheath (outer coating) material Insulation body materials
    1 ~ 100 - 0.2 ~ 0.3 23 ~ 25 - 18P 10.3 ~ 11.9 300V NA Oil Resistance UL Blue - PVC (Polyvinyl Chloride) PVC (Polyvinyl Chloride)
    From: ₹ 816.64
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    NA3VCSB UL Standard with Shield
    NA3VCSB UL Standard with Shield
    NA3VCSB UL Standard with Shield

    NA3VCSB UL Standard with Shield

    MISUMI

    300 V oil-resistant shielded cable for fixed signals, ULAWM2517 standard compliant.

    • VW-1
    • ULAWM
    • Oil-Resistant
    • Strand Wire
    • Single Shield
    • Twisted Pair
    • 300 V
    Overall Length(m) Specified Length(m) Conductor Cross Section(mm2) AWG size(AWG) Number Of Cores(Core) Logarithm Finished outer diameter(mm) Rated Voltage Shield Properties Representative Standard Sheath (outer coating) color Grounding Wire Sheath (outer coating) material Insulation body materials
    1 ~ 100 - 0.2 ~ 0.3 23 ~ 25 - 18P 10.8 ~ 12.6 300V Available Oil Resistance UL Blue - PVC (Polyvinyl Chloride) PVC (Polyvinyl Chloride)
    From: ₹ 1,068.44
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    NAKVVSB 100 V or less with Shield

    NAKVVSB 100 V or less with Shield

    MISUMI

    General-purpose shielded signal cable for low-current circuits with excellent oil resistance and noise resistance.

    • Oil-Resistant
    • Strand Wire
    • Single Shield
    • Twisted Pair
    • Less than 100 V
    Overall Length(m) Specified Length(m) Conductor Cross Section(mm2) AWG size(AWG) Number Of Cores(Core) Logarithm Finished outer diameter(mm) Rated Voltage Shield Properties Representative Standard Sheath (outer coating) color Grounding Wire Sheath (outer coating) material Insulation body materials
    1 ~ 100 - 0.2 ~ 0.3 23 ~ 25 - 18P 11 ~ 13.4 For Low Current Circuits Available Oil Resistance - Blue - PVC (Polyvinyl Chloride) PVC (Polyvinyl Chloride)
    From: ₹ 1,033.62
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
Brand
Product Series
From
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

You can add up to 6 items per a category to the compare list.

NA3VC UL Standard
    NA3VC UL Standard
    NA3VC UL Standard

    You can add up to 6 items per a category to the compare list.

    NA3VCSB UL Standard with Shield
      NA3VCSB UL Standard with Shield
      NA3VCSB UL Standard with Shield

      You can add up to 6 items per a category to the compare list.

      NAKVVSB 100 V or less with Shield
        Brand

        MISUMI

        MISUMI

        MISUMI

        Product Series

        NA3VC UL Standard

        NA3VCSB UL Standard with Shield

        NAKVVSB 100 V or less with Shield

        From

        ₹ 816.64-

        ₹ 1,068.44-

        ₹ 1,033.62-

        Days to Ship 6 Day(s) or more 6 Day(s) or more 6 Day(s) or more
        Specifications
        • VW-1
        • ULAWM
        • Oil-Resistant
        • Strand Wire
        • Twisted Pair
        • 300 V
        • VW-1
        • ULAWM
        • Oil-Resistant
        • Strand Wire
        • Single Shield
        • Twisted Pair
        • 300 V
        • Oil-Resistant
        • Strand Wire
        • Single Shield
        • Twisted Pair
        • Less than 100 V
        Overall Length(m)1 ~ 1001 ~ 1001 ~ 100
        Specified Length(m)---
        Conductor Cross Section(mm2)0.2 ~ 0.30.2 ~ 0.30.2 ~ 0.3
        AWG size(AWG)23 ~ 2523 ~ 2523 ~ 25
        Number Of Cores(Core)---
        Logarithm18P18P18P
        Finished outer diameter(mm)10.3 ~ 11.910.8 ~ 12.611 ~ 13.4
        Rated Voltage300V300VFor Low Current Circuits
        ShieldNAAvailableAvailable
        PropertiesOil ResistanceOil ResistanceOil Resistance
        Representative StandardULUL-
        Sheath (outer coating) colorBlueBlueBlue
        Grounding Wire---
        Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
        Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)

        Loading...