(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Communication Converter, K3SC (Part Number)

Communication Converter, K3SC
You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      20,707₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

Product Description

K3SC Interface Converter

[Features]
· Can be used in FA environments. Is small and so can be DIN rail mounted.
· Improves the ease of use of the RS-232C/USB<>RS-422/485 interface converter.
· A converter for connecting RS-232C/USB devices with RS-422/485 devices.
· It can be used in an FA environment (has passed equivalent controlling equipment environmental tests).
· CE marking compatibility (USB is exempted).
· UL/CSA certification of compliance (certification mark).
· For small width 30 mm, fitting screws DIN rail mounting.
· Switch echoback on/off.
· Adds USB<>RS-232C interface converter functionality.
· USBUSBdrivers are available for providing compatibility with virtual COM ports when using USB.

K3SC Interface Converter Outline Drawing And Specifications

K3SC-10 model

K3SC-10 model

  • *DIN track mounting is also possible.
Dimensional drawing

Dimensional drawing

Size (mm)Power Supply VoltageModel
30 (W) × 80 (H) × 78 (D)100 to 240 V ACK3SC-10 model 100 to 240 AC
24 V AC/DCK3SC-10 model 24 AC/DC

Product list

Power Supply Voltage100 to 240 V AC 50/60 Hz24 V AC 50/60 Hz, 24 V DC
Allowable Power Supply Variation Range85% to 110% of power supply voltage
Power Consumption5 VA max.3 VA max. / 3 W max.
Communications Configuration Of Master Device, Slave Device
(Select One Of The Options To The Right With The DIP Switch)
Communications configuration of master device ↔ Communications configuration of slave device
RS-232C, USB ↔ RS-485 half-duplex
RS-232C, USB ↔ RS-422 full-duplex
USB ↔ RS-232C full-duplex
Communication MethodStart-stop synchronization
Ambient Operating Temperature-10 to +55°C (with no icing)
Ambient Operating Humidity25 to 85% (with no condensation)
Ambient Storage Temperature-20 to +65°C

Rating
USB ambient operating temperature is 0 to 55°C (with no icing).

RS-232C
Interface
Maximum Transmission Distance15 m
Number Of Connectable Units1 unit
USB
Interface
Maximum Transmission Distance5 m; hub delay time + cable delay time ≤ 70 ns
Number Of Connectable Units1 unit
USB StandardV 1.1
RS-485
Interface
Maximum Transmission Distance500 m
Number Of Connectable Units31 units (for multi-drop connection)
RS-422
Interface
Maximum Transmission Distance500 m
Number Of Connectable Units1 unit
Baud Rate1,200/2,400/4,800/9,600/19,200/38,400 (bps)
Default setting: 9,600
Data Length7/8 bits, Default setting: 7
Stop Bit Length1/2 bits, Default setting: 2
Communications ParityNone/even/odd, Default setting: even
Echoback SelectionEchoback: with/without, Default setting: without
Selection Switch Response DelayApprox. 30 ms
Insulation Resistance 20 MΩ min. measured with a 500 V DC Megger
External terminals ↔ casing
RS-232C terminals and USB port ↔ RS-422/485 terminals ↔ power supply terminals
Insulation
Method
CommunicationsPhototransistor coupler
Power SupplyIsolating transformer
Dielectric Strength1,500 V AC for 1 minute measured between the following: External terminals ↔ casing
RS-232C terminals / USB port / RS-422 / 485 terminals ↔ power supply terminals
500 V AC for 1 minute measured between RS-232C terminals and USB port ↔ RS-422/485 terminals
Noise ImmunityAC power supply terminals, normal/common mode: ±1,500 V;
AC/DC power supply terminals, normal mode: ±480 V;
common mode: ±1,500 V:
Square wave with 1 ns rising edge ±1 µs, ±100 ns
Vibration ResistanceMalfunction10 to 55 Hz, 0.5 mm single amplitude for 10 minutes each in X, Y, and Z directions
Destruction10 to 55 Hz, 0.75 mm single amplitude for 2 hours each in X, Y, and Z directions
Shock ResistanceMalfunction98 m/s2 3 times each in X, Y, and Z directions
Destruction294 m/s2 3 times each in X, Y, and Z directions
MassApprox. 150 g
Enclosure RatingFront Panel Operation PartsConforms to IEC standards, equivalent to IP20 (when terminal cover mounted)
TerminalsEquivalent to VDE 0106/100 (when terminal cover mounted)
Compatible StandardsUL508 CAN/CSA C22.2 No.142
EN61010-1 EN61326-1 industrial electromagnetic environment applications
Memory ProtectionNo protective functions (communications data is not protected for power interruptions during communications)

Performance
The CE marking does not apply when the K3SC is used for USB.

  • With RS-232C communications, free-run mode is supported for SD and RD but not for any other signal lines.
  • The enclosure ratings do not apply when USB is used, as the terminal cover needs to be removed.
"m-h3--wysiwyg">Precautions when using this product
Do not touch any of the terminals while power is being supplied. Doing so may result in electric shock.

Do not touch any of the terminals while power is being supplied.
Doing so may result in electric shock.

Do not allow bits of metal or wire cuttings to enter the interior of the product. This may result in malfunction, fire, or electric shock.

Do not allow bits of metal or wire cuttings to enter the interior of the product.
This may result in malfunction, fire, or electric shock.

Do not attempt to disassemble, repair, or modify the product. Any attempt to do so may result in malfunction, fire, or electric shock.

Do not attempt to disassemble, repair, or modify the product.
Any attempt to do so may result in malfunction, fire, or electric shock.

Make sure that the power supply voltage is within the specified range. Otherwise, damage or burning may result.

Make sure that the power supply voltage is within the specified range.
Otherwise, damage or burning may result.

Tighten the terminal screws to the specified torque. Loose screws may result in burning or malfunction. The recommended tightening torque is 0.78 Nm

Tighten the terminal screws to the specified torque.
Loose screws may result in burning or malfunction.
The recommended tightening torque is 0.78 Nm

General Precautions

  • Do not mount the product in the following places:

(1) Locations subject to shock or vibration
(2) Outdoor locations or locations subject to direct sunlight, wind, or rain
(3) Locations subject to temperatures or humidity outside the specified ranges
(4) Locations subject to condensation or icing
(5) Locations subject to large amounts of dust
(6) Locations subject to flammable gases or objects
(7) Locations subject to corrosive gases (in particular sulfide or ammonia gases)

  • Be sure to check power supply specifications, terminal numbers, and polarities before performing wiring.
  • Turn OFF the power supply before performing installation or wiring.
  • Turn OFF the power supply before removing the terminal cover. Accidentally touching the terminals may result in electric shock.
  • Do not connect anything to unused terminals.
  • Do not touch the slits and terminals while power is being supplied.

Correct Use

  • Perform wiring with crimp terminals that are suitable for M3.5 screws.
  • Install the product as far away as possible from devices that generate strong high-frequency noise (e.g., high-frequency machines/welders) or surges.
  • Do not pull on the USB cable. Doing so may cause the cable to come loose.
  • Almost all application programs run with the K3SC-10 driver, which provides a virtual communications port for USB communications. Some application programs do not run, because this driver does not support all of the API functions.
  • The K3SC-10 is not simply a voltage level converter. Communications data is converted by a built-in CPU. Depending on communications conditions, processing may not be able to keep up with communications, and occasionally data corruption or data omissions may occur. If necessary, reduce the baud rate or the frequency of communications, or take other suitable countermeasures.
Part Number
K3SC-10 AC/DC24
Part NumberPriceMinimum Order Qty.Volume DiscountDays to Ship

₹ 20,707.00

1 Piece(s) 1 Day(s) or more

Loading...

  1. 1
 

Basic Information

Communication method before conversion Serial / USB Communication method after converting Serial Number of master-slave electrodes 1:1
Representative Standard CE / UL / CUL / CSA Dimension vertical(mm) 80 Dimension width(mm) 30
Dimension depth(mm) 78 Power Supply Voltage(V) AC/DC24 Master station communication mode RS-232C / USB
Slave station communication form RS-485 / RS-422 / RS-232C
X
whatsapp-qr whatsapp-icon