(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
[Features]
・ Noise resistance
・ Flexibility
· Oil resistance
・ UL, cUL standard cable
[Applications]
・ Wiring to the control circuit of the machine tool
・ Wiring in an oil environment
・ Wiring to the portion requiring noise resistance
UL AWM 2936/2576/2937/2935
Part Number | KVC-36SB | ||
---|---|---|---|
0.2 mm^2 | 0.3 mm^2 | 0.5 mm^2 | |
Conductor | Tin plated soft stranded copper wire | Annealed copper assembly line | |
Insulator | 105°C heat resistant vinyl mixture | ||
Conductor stranding | Twisted pair | — | |
Pair strand | Strands of twisted pair in circular form | Wire cores twisted into a circular shape | |
Tape | Tape wrap around cores | ||
Shield | Tin coated annealed copper braid | ||
Sheath | Oil and heat resistant vinyl (Black) |
Cable Type | UL/cUL | |||
---|---|---|---|---|
Compatible size | 2, 3 × 0.1 to 0.3 mm^2 | 4 to 64 × 0.1 to 0.3 mm^2 | 2 to 4 × 0.5 mm^2 | 5 to 60 × 0.5 mm^2 |
Rated Voltage | 150 V | 300 V | ||
Rated temperature | 80°C | |||
Test voltage | 1,500 V AC, 1 minute | 2,000 V AC, 1 minute | ||
Flame Retardancy | FT2 | VW-1, FT1 | ||
Compatible standard | UL AWM style 2936 CSA C22.2 No.210 | UL AWM style 2576 CSA C22.2 No.210 | UL AWM style 2937 CSA C22.2 No.210 | UL AWM style 2935 CSA C22.2 No.210 |
* Since the Electrical Appliances and Materials Safety Act of Japan does not apply to KVC-36SB, please use it for weak current collection circuits such as signal and communication circuits.
Conductor | Insulation | Number of conductors | Sheath outer diameter (approx. mm) | Approximate weight (kg/km) | Electrical characteristics | |||
---|---|---|---|---|---|---|---|---|
Nominal cross-sectional area | Outer Diameter (Approx. mm) 〈Configuration〉 | Outer Diameter (Approx. mm) | Allowable current (A) | Conductor resistance 20°C (Ω/km) | Insulation resistance 20°C (M Ω km) | |||
0.2 mm^2 [25AWG] | 0.54 [7/0.18] | 1.05 | 2 (1P) | 3.9 | 21 | 5 | 113 or less | 50 or more |
3 | 4.1 | 24 | 4 | |||||
4 (2P) | 5.7 | 40 | 4 | |||||
5 (2P+1) | 5.8 | 45 | 4 | |||||
6 (3P) | 5.9 | 45 | 4 | |||||
7 (3P+1) | 6.0 | 50 | 3 | |||||
8 (4P) | 6.4 | 55 | 3 | |||||
10 (5P) | 6.8 | 65 | 3 | |||||
12 (6P) | 7.5 | 75 | 3 | |||||
14 (7P) | 7.7 | 80 | 3 | |||||
15 (7P+1) | 7.8 | 80 | 3 | |||||
16 (8P) | 8.2 | 90 | 3 | |||||
20 (10P) | 9.0 | 105 | 2 | |||||
24 (12P) | 9.1 | 115 | 2 | |||||
30 (15P) | 10.0 | 140 | 2 | |||||
36 (18P) | 11.0 | 160 | 2 | |||||
40 (20P) | 11.5 | 170 | 2 | |||||
50 (25P) | 12.5 | 205 | 2 | |||||
60 (30P) | 14.0 | 245 | 2 | |||||
64 (32P) | 14.0 | 255 | 2 | |||||
0.3 mm^2 [23AWG] | 0.7 [12/0.18] | 1.3 | 2 (1P) | 4.6 | 28 | 7 | 62.3 or less | 50 or more |
3 | 4.8 | 35 | 6 | |||||
4 (2P) | 6.2 | 50 | 6 | |||||
5 (2P+1) | 6.4 | 55 | 5 | |||||
6 (3P) | 7.1 | 70 | 5 | |||||
7 (3P+1) | 7.2 | 70 | 5 | |||||
8 (4P) | 7.8 | 85 | 5 | |||||
10 (5P) | 8.5 | 100 | 4 | |||||
12 (6P) | 9.3 | 115 | 4 | |||||
14 (7P) | 9.4 | 120 | 4 | |||||
15 (7P+1) | 9.5 | 125 | 4 | |||||
16 (8P) | 10.0 | 135 | 4 | |||||
20 (10P) | 11.5 | 170 | 4 | |||||
24 (12P) | 12.0 | 185 | 3 | |||||
30 (15P) | 13.0 | 215 | 3 | |||||
36 (18P) | 14.0 | 255 | 3 | |||||
40 (20P) | 14.5 | 275 | 3 | |||||
50 (25P) | 15.5 | 335 | 3 | |||||
60 (30P) | 17.0 | 385 | 2 | |||||
64 (32P) | 17.5 | 405 | 2 | |||||
0.5 mm^2 [20AWG] | 0.95 [22/0.18] | 1.65 | 2 | 5.6 | 45 | 10 | 34.3 or less | 50 or more |
3 | 5.9 | 50 | 9 | |||||
4 | 6.3 | 60 | 8 | |||||
5 | 7.0 | 80 | 7 | |||||
6 | 7.7 | 95 | 7 | |||||
7 | 7.7 | 100 | 7 | |||||
8 | 8.2 | 115 | 6 | |||||
10 | 9.3 | 140 | 6 | |||||
12 | 9.6 | 150 | 6 | |||||
14 | 10.0 | 165 | 5 | |||||
15 | 10.5 | 175 | 5 | |||||
16 | 10.5 | 190 | 5 | |||||
20 | 12.0 | 225 | 5 | |||||
24 | 11.5 | 265 | 5 | |||||
25 | 13.0 | 275 | 4 | |||||
26 | 13.0 | 280 | 4 | |||||
30 | 13.5 | 310 | 4 | |||||
40 | 15.5 | 400 | 4 | |||||
50 | 17.0 | 490 | 4 | |||||
60 | 18.0 | 580 | 3 |
* The flame retardant level varies depending on the size. See "flame retardancy" in the technical data.
Ambient temperature (°C) | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 | 90 | 95 | 100 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current reduction factor | 1.00 | 0.97 | 0.93 | 0.89 | 0.86 | 0.82 | 0.77 | 0.73 | 0.68 | 0.63 | 0.58 | 0.52 | 0.45 | 0.36 | 0.26 |
■0.2, 0.3 mm^2
■0.5 mm^2
No. of Wire Cores | Wire core identification method |
---|---|
12 cores or less | Insulator coloring method (black, white, red, green, yellow, brown, blue, ash, orange, purple, peach, young grass in that order) |
13 cores or more | Numbering No. method (continuous display of 1, 2, 3, 4 on the surface of the white insulator) |
■Example: KVC-36SB 8 (4P) × 0.3 mm^2 (23AWG)
■Example: KVC-36SB 12 × 0.5 mm^2 (20AWG)
Part Number |
---|
KVC-36SB 16(8P)X0.5SQ-30 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship |
---|---|---|---|---|
₹ 23,608.52 | 1 Piece(s) | 7 Day(s) or more |
Loading...
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy