(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:30 10/11/2024 to 3:30 (IST) 11/11/2024. We apologize for the inconvenience.
  • Please note that the MISUMI Pune office and warehouse will be closed on November 20th due to the state election.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

NAVC UL Standard (Part Number)

NAVC UL Standard
You can add up to 6 items per a category to the compare list.

Part Number :
  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart


● It has a smaller outer diameter than the 300V rated signal cable.

· Refer to the wire core identification table.
· AWG25 1.5P is not a twisted pair.
· This product is compatible with "UL Traceability Program / Processed Wire." (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

Product Description

150 V fixed signal cable for small diameter, ULAWM2576/ULAWM2095 standard compliant, with excellent oil resistance.

Specifications

NAVC UL Standard:Related Image

Model NumberAWG
Size
Number of Pairs *4
1P = 2 Core (1PS = 2 Core)
Total Length *3
or
Specified Length
NAVC27
(Marked on Cable
AWG26 )
1PS1
~
100
(Specify 1 m
Increment)
/
500
/
1000
2P
3P
4P
5P
6P
7P
8P
10P
15P
20P
251PS
1P
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
15P
20P
25P
32P
231PS
1P
2P
3P
4P
5P
6P
7P
8P
10P
15P
20P
211P
2P
3P
4P
5P
6P
7P
8P
10P
15P
20P


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
*4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering. (Check the Specification Table for number of wire cores) 1P (1PS) is "x 2-core".

More Information

NAVC UL Standard:Related Image
NAVC UL Standard:Related Image
NAVC UL Standard:Related Image

Specifications

In terms of cable marking, AWG27 shows AWG26.
Model NumberAWG
Size
Number of Pairs
1P = 2 Cores
(1PS = 2-Core) *1
Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *6
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided* 5
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
NAVC271PS0.12Twisted Pair22.9103.7 143 or less10 or more15007/0.160.48Tin0.25PVC0.980.42PVCULAWM2095
2P44.723 2.8 146 or less0.85ULAWM2576
3P65.129 2.4
4P85.736 2.1
5P106.142 1.9
6P126.649 1.6
7P146.652 1.6
8P167.360 1.4
10P208.372 1.4
15P309.499 1.2
20P4010.4127 1.1
251PS0.223.112 4.3 113 or less10 or more15007/0.180.540.2551.050.45ULAWM2095
1P23.9184.3 0.85ULAWM2576
1.5P (twisted core)34.1213.8
2P45.126 3.3115 or less
3P65.333 2.8
4P85.840 2.5
5P106.248 2.3
6P12757 1.9
7P14760 1.9
8P167.669 1.7
10P208.481 1.7
15P309.7114 1.4
20P4010.9147 1.2
25P5011.7174 1.1
32P6413.2218 0.9
231PS0.323.617 6.3 65.8 or less10 or more150012/0.180.70.31.30.45ULAWM2095
1P24.425 6.3 67.1 or less0.85ULAWM2576
2P45.7354.9
3P66.547 4.1
4P86.857 3.6
5P107.4693.4
6P128.383 2.8
7P148.389 2.8
8P168.8102 2.5
10P2010121 2.5
15P3011.7172 2.1
20P4013.5226 1.8
211P0.524.831 8.8 39.5 or less10 or more150020/0.180.90.31.50.85ULAWM2576
2P46.957 6.7 40.3 or less
3P67.371 5.7
4P8881 5.0
5P108.7100 4.6
6P129.5119 3.9
7P149.5126 3.9
8P1610.2147 3.5
10P2012178 3.5
15P3013.8254 2.9
20P4015.3331 2.5


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material;
P... Polyester-based Material; Fluorine... Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

Current Reduction Factor
Ambient Temperature (°C)30405060708090100
Current Reduction Factor1.000.900.750.730.650.560.440.27
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current at AWG27 1PS core when the ambient temperature is 40°C
3.7 x 0.9 = 3.33 (A)

NAVC UL Standard:Related Image
NAVC UL Standard:Related Image
Part Number
NAVC-25-8P-94
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)

₹ 24,393.16

1 Piece(s) 6 Day(s) or more -940.2258P7.6

Loading...

  1. 1

Basic Information

Rated Voltage 150V Shield None Properties Oil resistance
Representative Standard UL Sheath (outer coating) color Navy color Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal For signals Other properties Pliability

Please check the type/dimensions/specifications of the part NAVC-25-8P-94 in the NAVC UL Standard series.

Product variants

Part Number
NAVC-21-1P-12
NAVC-21-1P-13
NAVC-21-1P-14
NAVC-25-8P-95
NAVC-25-8P-96
NAVC-25-8P-97
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Logarithm Finished outer diameter
(mm)

₹ 1,799.56

1 Piece(s) 6 Day(s) or more -120.5211P4.8

₹ 1,901.53

1 Piece(s) 6 Day(s) or more -130.5211P4.8

₹ 2,004.84

1 Piece(s) 6 Day(s) or more -140.5211P4.8

₹ 24,649.09

1 Piece(s) 6 Day(s) or more -950.2258P7.6

₹ 24,906.36

1 Piece(s) 6 Day(s) or more -960.2258P7.6

₹ 25,162.31

1 Piece(s) 6 Day(s) or more -970.2258P7.6
X
whatsapp-qr whatsapp-icon