(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

NA3VCSB UL Standard with Shield (NA3VCSB-21-3P-25)

NA3VCSB UL Standard with Shield (NA3VCSB-21-3P-25)

Move the mouse over or click the image to zoom

  • VW-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • 300 V
You can add up to 6 items per a category to the compare list.

Part Number :

This product is temporary NOT available. Please ask MISUMI to check the next available ship date.

  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart


· 1.5P of AWG25, AWG19, 16 are not twisted pairs.
· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

My Components
My Components
Similar ProductsSimilar Products
Product DetailProduct Detail

Product Description

300 V oil-resistant shielded cable for fixed signals, ULAWM2517 standard compliant.

NA3VCSB UL Standard with Shield (NA3VCSB-21-3P-25)

Move the mouse over or click the image to zoom

  • VW-1
  • ULAWM
  • Oil-Resistant
  • Strand Wire
  • Single Shield
  • Twisted Pair
  • 300 V
You can add up to 6 items per a category to the compare list.

Part Number :

This product is temporary NOT available. Please ask MISUMI to check the next available ship date.

  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart


· 1.5P of AWG25, AWG19, 16 are not twisted pairs.
· This product is compatible with "UL Traceability Program / Processed Wire". (c-UL is not compatible)
* For cables in stock, please keep in mind that because we cut them to the specified size, they cannot be canceled or returned.
* All unit prices are per meter.
Unit Price Calculation Method
[Formula: Last digits of model number (m) x unit price per meter above]
* Color and softness may vary slightly due to manufacturer changes.

Electrical Appliance and Material Safety Law certificate is not obtained.

PDF

Similar ProductsSimilar Products
Product DetailProduct Detail

Specifications

NA3VCSB UL Standard with Shield:Related Image

Model NumberAWG
Size
Core Number /
Pair Number* 4
1P = 2-core
NA3VCSB251P
1.5P (3-Core)
2P
3P
4P
5P
6P
7P
8P
10P
12P
13P
15P
18P
20P
25P
32P
231P
2P
3P
4P
5P
6P
7P
8P
10P
12P
18P
25P
211P
2P
3P
4P
5P
6P
7P
8P
10P
192
3
4
6
8
10
12
162
3
4
6
8


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our model numbers. Always specify quantity as number of units, not as meters.
*1 Stock products are indicated with T or A in the price column at right.
*2 All unit prices above are per meter.
Unit Price Calculation Method [Formula: Last digits of model number (m) x unit price per meter above]
*3 Please note that when ordering 1000 m and 500 m, the order will be delivered as 100 m windings (we cannot accept orders for single cables).
*4 Check the indications for number of cores, pair number, core / pair number, and pair number / core when ordering.

More Information

NA3VCSB UL Standard with Shield:Related Image
NA3VCSB UL Standard with Shield:Related Image
NA3VCSB UL Standard with Shield:Related Image

Specifications
Model NumberAWG
Size
Core Number / Pair Number * 1
1P = 2 Cores
Estimated
Section Area
(mm2) * 2
Twisted
Structure
(See Figure)
Number of
Wire Cores
Finished *6
Outer Diameter
(mm)
Approximate
Mass
kg/km
Electrical PropertiesConductorInsulationWire Core
Outer Diameter
Approx. (mm)
SheathSpecificationSample
Provided* 5
Allowable Current
A (30°C)* 3
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Withstand Voltage
V / Min
Structure
Strands / mm
Outer Diameter
Approx. (mm)
Plating *4Thickness
(mm)
Material *4Thickness
(mm)
Material *4
NA3VCSB251P0.2Twisted Pair24.431.54.4121 or less10 or more20007/0.180.54Tin0.23PVC1.00.9PVCULAWM2517
1.5P (twisted core)34.634.03.80.9
2P45.543.33.50.9
3P65.952.72.91.0
4P86.361.42.61.0
5P106.871.02.41.0
6P127.380.12.21.0
7P147.384.92.11.0
8P167.797.12.01.0
10P208.9114.81.81.0
12P249.3120.61.71.1
13P269.6130.21.61.1
15P3010.1137.51.51.1
18P3610.8180.41.41.2
20P4011.3195.01.31.2
25P5012.6235.51.21.3
32P6413.9290.91.11.4
231P0.324.835.76.371.1 or less10 or more200012/0.180.720.241.20.9
2P46.253.45.00.9
3P66.665.54.21.0
4P87.277.23.71.0
5P107.790.63.41.0
6P128.2106.43.11.0
7P148.2113.33.01.0
8P168.8126.32.81.1
10P2010.3152.72.61.0
12P2410.8175.42.41.2
18P3612.6232.72.11.3
25P5014.6320.91.71.4
211P0.525.243.38.841.9 or less10 or more200020/0.180.920.241.40.9
2P4770.67.01.0
3P67.385.05.81.0
4P87.9102.25.11.0
5P108.5123.94.81.0
6P129.4147.44.31.1
7P149.4156.34.11.1
8P1610.0171.03.91.1
10P2011.7210.63.61.2
1920.75Twisted Core Layer25.661.011.527.7 or less10 or more200030/0.181.130.241.60.9
33669.510.01.0
446.582.09.01.0
667.4106.87.61.0
887.9127.96.61.0
10109.0146.16.21.0
12129.3164.75.71.0
1621.2526.887.517.515.4 or less10 or more200054/0.181.530.282.11.0
337.2106.315.21.0
447.7125.813.71.0
668.9158.311.61.0
889.4190.910.11.0
 
NA3VCSB UL Standard with Shield:Related Image
NA3VCSB UL Standard with Shield:Related Image


*1 Please note that when the indicated Core / Pair is 1P (1PS), the number of wire cores will be "x 2-core".
*2 The size conversion is for reference only. Refer to the comparison table on >>Click here for details.
*3 The value of allowable current is to be used only as a reference value and is not guaranteed.
*4 How to View Materials
[Plating] Tin... Tin Plated Annealed Copper Wire
[Materials] PVC... Polyvinyl Chloride; PE... Polyethylene-based Material; P... Polyester-based Material; Fluorine...
Various Fluorine Resins; *... Other
*5 For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above.

Current Reduction Factor
Ambient Temperature (°C)30405060708090100
Current Reduction Factor1.000.900.750.730.650.560.440.27
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value 4.4 x 0.9 = 3.96 (A) when the ambient temperature for 2-core AWG25 is 40 °C
Part Number
NA3VCSB-21-3P-25
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)

₹ 9,626.49

1 Piece(s) 6 Day(s) or more -250.521-3P7.3
Part Number
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipRoHSOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Logarithm Finished outer diameter
(mm)
  1. 1

Basic Information

Rated Voltage 300V Shield Present Properties Oil resistance
Representative Standard UL Sheath (outer coating) color Navy color Sheath (outer coating) material PVC
Insulation body materials PVC Power supply/signal For signals Other properties Noise Resistance
  • Not a MISUMI customer yet?
  • Register and enjoy 20% Off
  • on your 1st order! *
  • Download CAD data and product data for more than 12 Mio. products.
  • Configure your drawing parts in the MISUMI Online Shop and save time and resources.
  • Reduce your process costs with the MISUMI Online Shop.
X
whatsapp-qr whatsapp-icon
Close

Comparison list

Please select a default language