(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Dynamic Connector Removal Tools (for D3100/D3200 Series) (Part Number)

Dynamic Connector Removal Tools (for D3100/D3200 Series)

Click this image to zoom it.

Move the mouse over or click the image to zoom

You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      3,252₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart


● Used to remove contacts that have been inserted into the housing.
● Manufacturer: Tyco Electronics

· Once extracted, the contact cannot be used again.

Product Description

Extraction tool that minimizes the load when extracting contact

Specifications

Dynamic Connector Removal Tools (for D3100/D3200 Series):Related Image

Model NumberWeight (g)
234168-1
17
Part Number
234168-1
Part NumberPriceMinimum Order Qty.Volume DiscountDays to Ship

₹ 3,252.00

1 Piece(s) 6 Day(s) or more

Loading...

  1. 1

Example

Dynamic Connector Removal Tools (for D3100/D3200 Series):Related Image

Dynamic / DK

Features

● Dynamic / DK connectors are compact nylon connectors developed especially for industrial equipment. With strengthened housing and contacts compared to conventional products, and a wide selection of housing types, these connectors are especially suited for use with FA equipment.
● Dynamic / DK connectors are suitable for both power supply and signal use.
● 3100 series with rated 250 V, 3200 series with rated 600 V, and 5200 series with rated 630 V available.
● The Dynamic Series and DK series are compatible connectors.

Common Specifications

● Uses the housing lance method
Fixing after the contact housing is installed commonly uses a locking method in which a lance on the contact side is latched on to the housing. These connectors instead use a housing lance method in which a lance is located on the housing. Because there is no lance on the contact, contacts will not become tangled during operation or storage, and issues such as the lance becoming deformed are eliminated. Consequently, insertion into the housing is easier, and secure connections are possible without the wires becoming disconnected. A locking sound when properly inserted notifies of a secure connection. Easy removal using a dedicated removal tool.
 

Design includes prying prevention structure

Both male (pin) (including circuit board connectors) and female (socket) connectors are ribbed (convex/concave) and interlock making them highly resistant to prying. Product features a built-in safety design - the male (pin) and female (socket) must be perfectly inserted with no looseness between the housing for contacts to connect.
● About contact pressure
Contact pressure is divided into high pressure and standard pressure based on the sub-beam position. Misumi standard inventory consists of gold-plated standard contact pressure models.
PlatingContact Pressure TypeContact PressureUseNumber of Insertions / Removals
GoldStandard Contact PressureApprox. 150 gFor multi-core circuits with frequent insertions / removals used for signal / power supply500 times
High Contact PressureApprox. 250 gFor signal, power supply, and motor applications with large vibration500 times
TinHigh Contact PressureApprox. 400 gFor signal and power supply applications with less frequent insertions / removals100 times
● Advantages of Gold-Plated Contacts
Choice of gold or silver plated contacts will depend on operational factors such as voltage, current, environment (vibration, temperature, gases, etc.), core numbers, etc.
In general, gold plating is recommended for industrial devices.

Plating Type and Electrical Capacity

 Gold PlateUndetermined ZoneTin-platedNot Plated (Reference)
Voltage3 V or less3 ~ 30 V30 ~ 100 V100V or more
Current1 A or less1 ~ 10 A1 ~ 10 A0.1A or more
As shown on the table listed above, gold plating must be used for conditions of 3 V ,1 A and below. Tin plated products may be used for 30 V, 1 A or higher applications. While tin plated products are appropriate for Clean Environments, please use gold-plated products for unfavorable environmental conditions such as high temperature/humidity, various gases, high vibration, frequent insertion/removal etc.
● Use of Tab / Recessed Contact Method
Use of the plate tab style on the male side and recessed style (to receive the flat plate) on the receiving female side improves the prying resistance of the structure. 3 point contact method provides highly reliable connections.

Easy insertion and removal

Simply insert the connector to plug it in. There will be an audible locking sound when it is properly inserted. In addition there is a fitting confirmation line that can also be used to check for proper fit. Pinch the 2 lock levers on both sides of the housing for easy removal.

Common Specifications (3100 and 3200 Series)

Material / Finish

Simply insert the connector to plug it in. There will be an audible locking sound when it is properly inserted. In addition there is a fitting confirmation line that can also be used to check for proper fit. Pinch the 2 lock levers on both sides of the housing for easy removal.
TypeMaterialFinish
Female ContactCopper AlloyGloss Tin-Plating and Gold Plating Over Nickel Base
Male Contact
HousingUL94V-0, Polyester with Glass Fiber Reinforcement (PBT), PPS (SMT type), Black

Compatible Wire Size

 AWGConductor Section Area mm2
Size28 ~ 160.08 ~ 1.25

Specifications

ItemD3100 SeriesD3200 Series
Rated Voltage250 VAC / VDC or less600 VAC / VDC or less
Rated Current*1-core: 12A
3-core: 15 A
6-core: 10A
16-core: 8A
(Used with AWG16 wires)
Withstand Voltage1,500 VAC / minute2,200 VAC / minute
Contact Resistance10 mΩ or less
Operating Temperature Range-55°C ~ +105°C
Insulation Resistance1,000 MΩ or higher
Insertion / Removal Force (per core)Insertion: 500 g or less. Removal: 30 g or more
Contact Retention Force49N or more
Temperature Rise (Rated Conditions)30°C or less
DurabilityContact resistance at 10 mΩ or less after 500 trials (100 mm/min.) of insertions and removals
* Rated current value indicates the current value per core. Consequently, a 6 core connector can handle a current of 60 A. However, please be aware that rated current value per core will decline as the number of cores increases. If you don't see your desired core count on the chart to the left, please use the current curve below for reference.

Rating

Specifications / Series3100 Series (3.81 mm pitch)3200 Series (5.08 mm pitch)
Rated VoltageRated CurrentRated TemperatureRated VoltageRated CurrentRated Temperature
AMP Standard
108-5349
250 V(See table below)-55°C ~ +105°C600 V
(single connector use)
(See table below)-55°C ~ +105°C
UL
File
No.E28476
(Recognized
Component)
Determined
by conditions specific to
the device in use
Determined
by conditions specific to
the device in use
-Determined
by conditions specific to
the device in use
Determined
by conditions specific to
the device in use
-
CSA
Report No.
LR7189
250 V8 A, max.-250 V8 A, max.-
TÜV
License No.
R9151488
(VDE0627)
IP Protection, IP-00
Overvoltage Category (II)
Repeated Insertion/
Removal: 50 times
250 V
AWGA
282
263
243
224
205
186
168
148
-20°C ~ +105°C500 V
AWGA
282
263
243
224
205
186
168
148
-20°C ~ +105°C

Common Specifications (5200 Series)

Specifications

Rated Voltage630 VAC / VDC
Rated Current30 A max. (Refer to Table A)
Withstand Voltage3,000 VAC (1 minute)
Insulation Resistance1,000 MΩ or higher
Contact Resistance2 mΩ or less
Applicable Electric Wire RangeAWG16 ~ 10 (1.23 ~ 5.50 mm2)
Suitable Electric Wire Insulation Coating Outer Diameter3.0 ~ 5.2 mm
Operating Temperature Range-55 ~ +105°C
Compatible Panel Thickness1.6 ~ 2.4 mm ±0.1
Table A
Used Wire Size (AWG)10121416
Current (Ampere)30251916

Material / Finish

TypeMaterialFinish
Female ContactCopper AlloyGold plated over nickel base coat
and silver plated over nickel base coat
Male Contact
HousingUL94V-0, polyester with glass fiber reinforcement (PBT), black
 

[Compatibility Table]

3100 Series
D3100DK3100
1-178288-3-20PMDK-3100S-03R-20P
1-178288-5-20PMDK-3100S-05R-20P
178289-3-20PMDK-3100D-06R-20P
178289-5-20PMDK-3100D-10R-20P
1-177648-3-20PMDK-3100S-03F-20P
1-177648-5-20PMDK-3100S-05F-20P
178964-3-20PMDK-3100D-06F-20P
178964-5-20PMDK-3100D-10F-20P
1-178802-3-20PMDK-3100S-03P-20P
1-178802-5-20PMDK-3100S-05P-20P
178803-3-20PMDK-3100D-06P-20P
178803-5-20PMDK-3100D-10P-20P
3200 Series
D3200DK3200
1-178128-2-20PMDK-3200S-02R-20P
1-178128-3-20PMDK-3200S-03R-20P
1-178128-4-20PMDK-3200S-04R-20P
1-179552-2-20PMDK-3200S-02F-20P
1-179552-3-20PMDK-3200S-03F-20P
1-179552-4-20PMDK-3200S-04F-20P
1-179553-2-20PMDK-3200S-02P-20P
1-179553-3-20PMDK-3200S-03P-20P
1-179553-4-20PMDK-3200S-04P-20P
5200 Series
D5200DK5200
1-179958-2-10PMDK-5200S-02R-10P
1-179958-3-10PMDK-5200S-03R-10P
1-353046-2-10PMDK-5200S-02F-10P
1-353046-3-10PMDK-5200S-03F-10P
 
5200 Contact
D5200DK5200
917804-2MDK-5TABSLP1-100P
316040-2MDK-5RECSLP1-100P
917805-2MDK-5TABMLP1-100P
316041-2MDK-5RECMLP1-100P
 
3100 / 3200 Common Contact
D3100 / D3200DK3100 / DK3200
175287-2MDK-3TABSLP1-100P
175288-2MDK-3TABMLP1-100P
175289-2MDK-3TABLLP1-100P
175216-2MDK-3RECSLP1-100P
175217-2MDK-3RECMLP1-100P
175218-2MDK-3RECLLP1-100P

Basic Information

Applicable type Dynamic Connector Extraction Tool Product classification Extraction Tool

Please check the type/dimensions/specifications of the part 234168-1 in the Dynamic Connector Removal Tools (for D3100/D3200 Series) series.

X
whatsapp-qr whatsapp-icon