NCS Straight/Relay/Panel Mountable Connector Harness (Part Number)

NCS Straight/Relay/Panel Mountable Connector Harness
You can add up to 6 items per a category to the compare list.

Part Number :
  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart


● Ideal for relay cables thanks to its superior strength.
● Oil-resistant / soft cables are available.
● By taking advantage of the free alteration / custom number, customization of connection changes, mark tube printing, and sheath strip lengths is possible.
● Supports cable shapes other than those described with "WEB Design Harness Plus."



· Straight plugs cannot be mated with one another. Use a panel mount receptacle or a cable for relays when setting up a relay.

Wiring and Wire Color Page >>Click here


Product Description

A harness with an NCS connector from NANABOSHI ELECTRIC MFG CO., LTD. Cables for power supply applications and general-purpose applications can be selected. The lineup includes oil resistant and flexible cables.

Specifications

NCS Straight/Relay/Panel Mountable Connector Harness:Related Image

Connector TypeShape Specification TypeOutline Image Drawing (Unit: mm)Shell SizeNumber of CoresCableSpecified Length
(m)
CNCS
(NCS Series)

Nanaboshi Electric Mfg.Co,Ltd.
P
(Female Straight / Cut Off)
PP
(Female Straight / Female Straight)
PT
(Female Straight / Pin No. Insertion Mark Tube)
PY
(Female Straight / Y Terminal)
 NCS Straight/Relay/Panel Mountable Connector Harness:Related Image142NCS Straight/Relay/Panel Mountable Connector Harness:Related Image0.2


~


50


Can be specified by
0.1
m increments
16
25
30
2
3
4
ADF
(Female Relay / Cut Off)
ADFADF
(Female Relay / Female Relay)
ADFT
(Female Relay / Pin No. Insertion Mark Tube)
ADFY
(Female Relay / Y Terminal)
 NCS Straight/Relay/Panel Mountable Connector Harness:Related Image162
3
252
3
4
30
RF
(Female Panel Mount / Cut Off)
RFT
(Female Panel Mount /
Pin No. Insertion Mark Tube)
RFY
(Female Panel Mount / Y Terminal)

* Panel mount will be flange type.
 NCS Straight/Relay/Panel Mountable Connector Harness:Related Image162
3
252
3
4
30
PM
(Male Straight / Cut Off)
PMPM
(Male Straight / Male Straight)
PMT
(Male Straight / Pin No. Insertion Mark Tube)
PMY
(Male Straight / Y Terminal)
 NCS Straight/Relay/Panel Mountable Connector Harness:Related Image162
3
Connector
252
3
4
30

Connector TypeShape Specification TypeOutline Image Drawing (Unit: mm)Shell SizeNumber of CoresCableSpecified Length
(m)
CNCS
(NCS Series)

Nanaboshi Electric Mfg.Co,Ltd.
ADM
(Male Relay / Cut Off)
ADMADM
(Male Relay / Male Relay)
ADMT
(Male Relay / Pin No. Insertion Mark Tube)
ADMY
(Male Relay / Y Terminal)
 NCS Straight/Relay/Panel Mountable Connector Harness:Related Image162
3
NCS Straight/Relay/Panel Mountable Connector Harness:Related Image
 
0.2


~


50


Can be specified by
0.1
m increments
252
3
4
30
R
(Male Panel Mount / Cut Off)
RT
(Male Panel Mount / Pin No. Insertion Mark Tube)
RY
(Male Panel Mount / Y Terminal)

* Panel mount will be flange type.
 NCS Straight/Relay/Panel Mountable Connector Harness:Related Image162
3
4
25
30
Connector
PFPM
(Female Straight / Male Straight)
ADFPF
(Female Relay / Female Straight)
ADFPM
(Female Relay / Male Straight)
ADMPF
(Male Relay / Female Straight)
ADMPM
(Male Relay / Male Straight)
ADFADM
(Female Relay / Male Relay)
NCS Straight/Relay/Panel Mountable Connector Harness:Related Image162
3
252
3
4
303
4

Shape Specification
Type
Shell
Size
Number of Cores
P142
162
3
4
252
3
4
302
3
4
PP142
162
3
4
252
3
4
302
3
4
PT142
162
3
4
252
3
4
302
3
4
PY142
162
3
4
252
3
4
302
3
4
ADF162
3
252
3
4
303
4
ADFADF162
3
252
3
4
303
4
ADFT162
3
252
3
4
303
4
ADFY162
3
252
3
4
303
4
RF162
3
252
3
4
302
3
4
RFT162
3
252
3
4
302
3
4
RFY162
3
252
3
4
302
3
4
PM162
3
252
3
4
302
3
4
PMPM162
3
252
3
4
302
3
4
PMT162
3
252
3
4
302
3
4
PMY162
3
252
3
4
302
3
4
ADM162
3
252
3
4
303
4
ADMADM162
3
252
3
4
303
4
ADMT162
3
252
3
4
303
4
ADMY162
3
252
3
4
303
4
R162
3
4
252
3
4
302
3
4
RT162
3
4
252
3
4
302
3
4
RY162
3
4
252
3
4
302
3
4
PFPM162
3
252
3
4
303
4
ADFPF162
3
252
3
4
303
4
ADFPM162
3
252
3
4
303
4
ADMPF162
3
252
3
4
303
4
ADMPM162
3
252
3
4
303
4
ADFADM162
3
252
3
4
303
4

Specified Length (m)~ 0.91 ~ 44.1 ~ 50
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.

More Information

NCS Straight/Relay/Panel Mountable Connector Harness:Related Image



Electrical Properties
Connector Type
(Shell Size- No. of Cores)
ConnectorA Cable C Cable
Rated Current
(A or less)
Rated Voltage
(V or less)
Section AreaRated VoltageAllowable Current
A (30°C)
Section AreaRated VoltageAllowable Current
A (30°C)
14-251250.75mm2
(AWG18)
300V70.75mm2
(AWG18)
300V6
16-2
16-35
16-44
25-2102502.0mm2
(AWG14)
172.0mm2
(AWG14)
15
25-313
25-411
30-21515
30-313
30-411
* The values are reference values, not guaranteed values.
Part Number
CNCS-RY-30-3-A-[0.2-50/0.1]
CNCS-RY-30-3-C-[0.2-50/0.1]
CNCS-RY-30-4-A-[0.2-50/0.1]
CNCS-RY-30-4-C-[0.2-50/0.1]
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipCN1 CN2 Number Of Cores Shell size Cable standard (UL/CSA) Cable color Twisted pair Conductor dimensions
(AWG)
Environment resistant Bend tolerant Cable type Specified Length
(M)

-

1 Piece(s) 8 Day(s) or more Male panel mountY terminal[3] 330N/AGrayN/A14N/AN/AA0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male panel mountY terminal[3] 330N/ANavyN/A14Oil-resistantFlexibleC0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male panel mountY terminal430N/AGrayN/A14N/AN/AA0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male panel mountY terminal430N/ANavyN/A14Oil-resistantFlexibleC0.2 ~ 50

Loading...

General-purpose Large Metal Connector (NCS)

Features

● NCS series connectors are round metal connectors that have been used conventionally as general-purpose type connectors.
● The structure is simple, robust, mechanically and electrically stable; some items have acquired the mark (Electrical Appliance and Material Safety Act compliant), so they can be used widely from power supply to signal transmission.
● There are 10 shell sizes, each of which offers a selection among panel mounting, cable mounting, and relay mounting, providing a wide variety of combinations to suit the application.
● Because these connectors are all connected by soldering, no dedicated tool is required for wiring.
● The structure is an original design and cannot be coupled with other companies' products.

Common Specifications

Material / Finish

Item Materials Finish
Shell / Dustproof Cap Zinc Alloy or Brass Chrome Plated or special chemical processing
Insulator Epoxy Resin
Contact Copper Alloy Nickel-plated (Shell Size 14 ~ 30)
Silver-plated (Shell Size 40 ~ 60)
Gold-plated (Shell Size 30, 13-core)

Combination Method

Combination Method

Characteristics

Item Characteristics
Rated Voltage, Current Check with the table below.
Limit Operating Voltage Check with the table below. Shows the limit voltage value for continuous use of the NCS connector.
Withstand Voltage No abnormality such as short circuiting occurs when regulated voltage (see table below) is applied for 1 minute between immediately adjacent conductors.
Insulation Resistance Check with the table below. Resistance value when measured between immediately adjacent conductors with specified voltage.
Contact Resistance Check with the table below. Conductor resistance value when a pair of contacts are connected at up to the regulation length
Humidity Resistance No functional defect was found during the JIS-C-8306 humidity test, and the insulation resistance is 10 mΩ or higher.
Heat Resistance Test No functional defect was found during the JIS-C-8306 heat resistance test.
Temperature Rise Under correct operating conditions, the temperature rise in conducting parts is 40°C or less when rated current is flowing.
Corrosion Resistance No functional defect was found during the JIS C 5028 salt water spray test.
Allowable Operating Temperature Range -40°C ~ +120°C

Shell
Size
Number of Cores Shape Symbol Rated Current
(A or less)
Rated Voltage
(V or less)
Limit Operating Voltage (Note) Withstand Voltage (VAC) Insulation Resistance
(MΩ or higher)
Contact Resistance
(mΩ or less)
Applicable Electric Wire Size
Conductor Cross-sectional Area mm2 Parentheses show AWG
Applicable Electric Wire Finished Outer Diameter (mm)
14 1.2 P, R, AD 5 125 200 1,000 2,000 3 0.75 (18) φ5.5 ~ 7.0
16 1 P, R
AD
10 125 200 1,000 2,000 3 1.25 (18) φ6.5 ~ 8.0
2.3.4 5 0.75 (18)
16 2.3 PM, RF, ADF 5 125 200 1,000 2,000 3 0.75 (18) φ6.5 ~ 8.0
25 2.3.4 P, R, AD
GP1-2, LP
10 250 400 2,000 2,000 3 2 (14) φ9.5 ~ 11.5
5 1,800
6.7 300
8 5 1.25 (16)
25 2.3.4 PM, RF, ADF
GPM1-2
10 250 400 2,000 2,000 3 2 (14) φ9.5 ~ 11.5
5 1,800 1.25 (16)
6.7 5 300
30 2 P, R, AD
GP1-2
15 250 400 2,000 2,000 3 3.5 (12) φ11.0 ~ 13.0
3.4 2 (14)
5.6.7 1,800
8 10 300
13 5 - 1,500 1.25 (16)
30 2.3.4 PM, RF, ADF
GPM1-2
15 250 400 2,000 2,000 3 2 (14) φ11.0 ~ 13.0
5 1,800
6 10 -
8 5 300 1.25 (16)
40 2.3.4 PM, RF, ADF
GP1
30 250 500 2,500 2,000 3 5.5 (10) φ15.0 ~ 17.0
5.6.8 20 400 2,000
10 3-piece - 10, 7-piece - 5 300 1,800 Contact No. 1, 9, 10-2 (14) , Others - 1.25 (16)
12 3-piece - 10, 9-piece - 5 Contact No. 1, 9, 10-2 (14) , Others - 1.25 (16)
16 3-piece - 10, 13-piece - 5 Contact No. 1, 14, 15-2 (14) , Others - 1.25 (16)
20 5 1.25 (16)
44 2.3.4 PM, RF, ADF
GPM1
30 250 500 2,500 2,000 3 5.5 (10) φ15.0 ~ 19.0
5.6.8 20 400 2,000
10 3-piece - 10, 7-piece - 5 300 1,800 Contact No. 1, 9, 10-2 (14) , Others - 1.25 (16)
12 3-piece - 10, 9-piece - 5 Contact No. 1, 9, 10-2 (14) , Others - 1.25 (16)
16 3-piece - 10, 13-piece - 5 Contact No. 1, 14, 15-2 (14) , Others - 1.25 (16)
20 5 1.25 (16)
50 2.3 P, R, AD
GP1
80 500 600 3,000 5,000 1 30 (2) φ19.0 ~ 23.0
4 50 250 500 2,500 2,000 3 14 (6)
8 25 400 2,000 3.5 (12)
10 20 300
15 15
25 4-piece - 15, 21-piece - 5 1,800 Contact No. 3, 6, 19, 22-3.5 (12), Others - 2 (14)
54 2.3 PM, RF, ADF
GPM1
80 500 600 3,000 5,000 1 30 (2) φ19.0 ~ 26.0
4 50 250 500 2,500 2,000 3 14 (6)
8 25 400 2,000 3.5 (12)
10 20 300
15 15
25 4-piece - 15, 21-piece - 5 1,800 Contact No. 3, 6, 19, 22-3.5 (12), Others - 2 (14)
60 2 P, R, AD
GP1.25
150 500 600 3,000 5,000 1 50 (0) φ29.0 ~ 33.0
3
4 80 30 (2)
10 30 250 300 2,500 2,000 3 8 (8)
15 15 3.5 (12)
30, 40 5 1,500 2 (14)
32 3-piece - 15, 29-piece - 5 Contact No. 2, 24, 28-3.5 (12), Others - 2 (14)
60 10 PM, RF, ADF
GPM1.25
30 250 300 2,000 2,000 3 8 (8) φ29.0 ~ 33.0
15 15 3.5 (12)
30 5 1,500 2 (14)
32 3-piece - 15, 29-piece - 5 1,800 Contact No. 2, 24, 28-3.5 (12), Others - 2 (14)
64 2 PM, RF, ADF
GPM1.25
150 500 600 3,000 5,000 1 50 (0) φ31.0 ~ 36.0
3
4 80 30 (2)
(Note): Shows the limit voltage value for continuous use of the NCS connector. Follow the rated voltage if there is no indication on the connector.

NCS Connector Contact Arrangement Diagram

NCS Connector Contact Arrangement Diagram

NCS Connector Contact Arrangement Diagram

Connection Work Method

1. Disassemble the connector according to the following.
Connector
Note: If a contact for 80 A or 150 A is mounted, use the following procedure.

(1) Loosen the lock screws and remove the insulator from the connector body (turn counterclockwise)
(2) Loosen the clamp screws and remove the clamp saddle from the connector body
Contact Wrench
(1) Insert the contact wrench from the coupling side and remove the contact locking nut
2. Pass the disassembled parts through the cable in the order shown below.

Note: Avoid mistakes in the order or direction of parts.
Parts
3. Following the figure and table below, perform preparatory soldering for the core wires of the end-processed cable.

Cable End Processing Dimensional Drawing
4. Solder

With Solder (1) Insert the core wire with extra solder into the contact solder pot
(2) Heat the contact and the core wire with a soldering iron (conductor cross-sectional area 0.75 ~ 3.5 mm2 (AWG18 ~ AWG12) 30 seconds or less, and conductor cross-sectional area 5.5 ~ 14 mm2 (AWG10 ~ AWG6) 60 seconds or less)
(3) Apply solder and fill the gap between the contact and the core wires

5. Assemble the connector according to the following.

Connector (1) Screw the insulator firmly to the connector body (contacts for 80 A and 150 A should be installed with a contact wrench beforehand)
(2) Tighten the lock screws (tighten the connector body and insulator to the extent that they do not loosen when rotated by hand)
(3) Tighten the clamp screw and attach the clamp saddle to the plug body

Conductor Area and Soldering Iron

Soldering Iron
Wattage
Iron Tip
Temperature (°C)
Wire Size (Upper Part mm2, Lower Part AWG)
0.75 1,25 2 3.5 5.5 8 14
18 16 14 12 10 8 6
15 W 320
~
370
30 W
60 W
80 W
100 W
150 W
200 W

Cable End Processing Dimensional Table

Shape Symbols for P and AD (LP, GP * Common)
· Shape symbols LP, GP * are the same as P.
· Shape symbol R is the same as AD, but can be used with A dimension at the length of your choice.
Product No. Terminal Number A B Product No. Terminal Number A B Product No. Terminal Number A B Product No. Terminal Number A B
NCS-14-1-P All Poles 13.5 6 NCS-40-5-P All Poles 23 10 NCS-14-1-AD All Poles 20 6 NCS-40-5-AD All Poles 35 10
NCS-14-2-P 1
2
11
10
3.5
4
NCS-40-6-P 6
Other Poles
22
23
NCS-14-2-AD NCS-40-6-AD
NCS-16-1-P All Poles 13 6 NCS-40-8-P 8 Other Poles 22
23
NCS-16-1-AD 11 NCS-40-8-AD
NCS-16-2-P 1
2
13
11
4 NCS-40-10-P 1.9.10
Other Poles
22
23
7 NCS-16-2-AD 20 NCS-40-10-AD 1.9.10
Other Poles
34
35
7
NCS-16-3-P 1
2.3
11
13
NCS-40-12-P NCS-16-3-AD NCS-40-12-AD
NCS-16-4-P 1.2.4
3
11
10
NCS-40-16-P 1.14.15
Other Poles
22
23
NCS-16-4-AD NCS-40-16-AD 1.14.15
Other Poles
34
35
NCS-25-2-P All Poles 18 8 NCS-40-20-P 1.6.9
Other Poles
22
23
NCS-25-2-AD 24 7 NCS-40-20-AD All Poles 35
NCS-25-3-P NCS-50-2-P All Poles 35 13 NCS-25-3-AD NCS-50-2-AD 42 13
NCS-25-4-P NCS-50-3-P NCS-25-4-AD NCS-50-3-AD
NCS-25-5-P 17 7 NCS-50-4-P 33 11 NCS-25-5-AD NCS-50-4-AD 40 11
NCS-25-6-P 6
Other Poles
13
17
NCS-50-8-P 8
Other Poles
32
34
7 NCS-25-6-AD NCS-50-8-AD 7
NCS-25-7-P 7
Other Poles
13
17
NCS-50-10-P 10
Other Poles
32
36
NCS-25-7-AD NCS-50-10-AD
NCS-25-8-P 8
Other Poles
13
17
NCS-50-15-P All Poles 34 9 NCS-25-8-AD NCS-50-15-AD 42 9
NCS-30-2-P All Poles 19 8 NCS-50-25-P 3.6.19.22
Other Poles
30
34
9
8
NCS-30-2-AD 24 8 NCS-50-25-AD 3.6.19.22
Other Poles
42
43
9
8
NCS-30-3-P 7 NCS-60-2-P All Poles 43 15 NCS-30-3-AD 7.5 NCS-60-2-AD All Poles 45 15
NCS-30-4-P NCS-60-3-P NCS-30-4-AD NCS-60-3-AD
NCS-30-5-P NCS-60-4-P 13 NCS-30-5-AD NCS-60-4-AD 13
NCS-30-6-P 6
Other Poles
16
19
NCS-60-10-P 41 12 NCS-30-6-AD NCS-60-10-AD 47 12
NCS-30-7-P 7
Other Poles
16
19
NCS-60-15-P 9 NCS-30-7-AD NCS-60-15-AD 9
NCS-30-7H-P All Poles 19 NCS-60-30-P 43 8 NCS-30-7H-AD 7 NCS-60-30-AD 48 8
NCS-30-8-P 8
Other Poles
16
19
NCS-60-32-P 2.24.28
Other Poles
39
43
9
8
NCS-30-8-AD NCS-60-32-AD 2.24.28
Other Poles
47
48
9
8
NCS-30-13-P All Poles 17 6 NCS-60-40-P All Poles 43 8 NCS-30-13-AD 6 NCS-60-40-AD All Poles 48 8
NCS-40-2-P 22 10 NCS-40-2-AD 35 6
NCS-40-3-P NCS-40-3-AD
NCS-40-4-P NCS-40-4-AD
Shape Symbols for P and AD (LP, GP * Common)
· Shape symbols LP, GP * are the same as P.
· Shape symbol R is the same as AD, but can be used with A dimension at the length of your choice.
Product No. Terminal Number A B Product No. Terminal Number A B Product No. Terminal Number A B Product No. Terminal Number A B
NCS-16-2-PM All Poles 13 6 NCS-44-16-PM 1.14.15
Other Poles
25
26
7 NCS-16-2-ADF All Poles 20 6 NCS-44-16-ADF 1.14.15
Other Poles
31
32
7
NCS-16-3-PM NCS-44-20-PM All Poles 26 NCS-16-3-ADF NCS-44-20-ADF 1.6.9
Other Poles
31
32
NCS-25-2-PM 18 7 NCS-54-2-PM 45 13 NCS-25-2-ADF 24 8 NCS-54-2-ADF All Poles 50 13
NCS-25-3-PM NCS-54-3-PM NCS-25-3-ADF 7 NCS-54-3-ADF
NCS-25-4-PM NCS-54-4-PM 43 11 NCS-25-4-ADF NCS-54-4-ADF 46 11
NCS-25-5-PM 6 NCS-54-8-PM 7 NCS-25-5-ADF 6 NCS-54-8-ADF 8 Other Poles 45 47 7
NCS-25-6-PM NCS-54-10-PM NCS-25-6-ADF NCS-54-10-ADF 10
Other Poles
45
47
NCS-25-7-PM NCS-54-15-PM 45 9 NCS-25-7-ADF NCS-54-15-ADF All Poles 47 9
NCS-30-2-PM 22 8 NCS-54-25-PM 3.6.19.22
Other Poles
45
48
9
8
NCS-30-2-ADF 26 8 NCS-54-25-ADF 3.6.19.22
Other Poles
31
35
9
8
NCS-30-3-PM NCS-60-10-PM All Poles 46 12 NCS-30-3-ADF 7 NCS-60-10-ADF All Poles 41 12
NCS-30-4-PM NCS-60-15-PM 9 NCS-30-4-ADF NCS-60-10-ADF 9
NCS-30-5-PM 21 NCS-60-30-PM 47
46
8 NCS-30-5-ADF NCS-60-30-ADF 43 8
NCS-30-6-PM 20 7 NCS-60-32-PM 2.24.28
Other Poles
47 9
8
NCS-30-6-ADF NCS-60-32-ADF 2.24.28
Other Poles
39
43
9
8
NCS-30-8-PM NCS-64-2-PM All Poles 47 15 NCS-30-8-ADF NCS-64-2-ADF All Poles 47 15
NCS-44-2-PM 26 10 NCS-64-3-PM NCS-44-2-ADF 31 10 NCS-64-3-ADF
NCS-44-3-PM NCS-64-4-PM 13 NCS-44-3-ADF NCS-64-4-ADF 13
NCS-44-4-PM NCS-44-4-ADF
NCS-44-5-PM NCS-44-5-ADF 32
NCS-44-6-PM NCS-44-6-ADF 6
Other Poles
31
32
NCS-44-8-PM NCS-44-8-ADF 8
Other Poles
31
32
NCS-44-10-PM 1.9.10
All Poles
25
26
7 NCS-44-10-ADF 1.9.10
Other Poles
31
32
7
NCS-44-12-PM NCS-44-12-ADF

Basic Information

Connector type NCS Connector manufacturer Nanaboshi Electric Mfg. Co., Ltd. Cable rated voltage(V) 300
Cable shape Circular Shield N/A