(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Due to an increase in demand, the lead time of some of the electrical items from our eCatalogue has increased abnormally and may cause delays in delivery or order suspension. We apologize for the inconvenience and appreciate your kind understanding. Once the supply will get normalized, we will update the same.

Cable with R04 Connector For Relay

Cable with R04 Connector For Relay
You can add up to 6 items per a category to the compare list.

Part Number :
  • Order Qty :
  • Price :
    ---
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart


● A cable with attached R04 connectors used widely as inter-device connections.
● By taking advantage of the free alteration / custom number, customization of connection changes, mark tube printing, and sheath strip lengths is possible. >>Click here

· Shield will be cut off by the connector base (not connected).
Since connectors are not yet supported, customized connections are also not available. Alteration service is not available for earth wire mounting, even with standard products.


Wiring and Wire Color Page
>>Click here
Component Page
>>Click here

Product Description

An environment-resistant and waterproof connector harness using TAJIMI Electronics ER04

Specifications

Cable with R04 Connector For Relay:Related Image

Specified Length (m)~ 0.91 ~ 44.1 ~ 50
Tolerance+20mm+50mm+ 3% of Specified Length
* The tolerance of the specified length is as described above.

Connector TypeShape Specification
Type
Outline Image Drawing (Unit: mm)Cable TypeNumber of CoresSpecified Length
(m)
R04J

TAJIMI
ELECTRONICS CO., LTD.
JP
(Male Relay)
Cable with R04 Connector For Relay:Related ImageCable with R04 Connector For Relay:Related Image20.2

~

50


Can be specified by
0.1m
increments
3
5
6
8
12
JS
(Female Relay)
Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
JPT
(Male Relay / Loose Wires)
With Pin No. Insertion Mark Tube
Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
JST
(Female Relay / Loose Wires)
With Pin No. Insertion Mark Tube
Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
JPY
(Male Relay /
Y Terminal)
With Pin No. Insertion Mark Tube
Cable with R04 Connector For Relay:Related Image2
3
5
Connector6
8
12
JSY
(Female Relay /
Y Terminal)
With Pin No. Insertion Mark Tube
Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12

Connector TypeShape Specification
Type
Outline Image Drawing (Unit: mm)Cable TypeNumber of CoresSpecified Length
(m)
R04J

TAJIMI
ELECTRONICS CO., LTD.
JPJP
(Male Relay / Male Relay)
Cable with R04 Connector For Relay:Related ImageCable with R04 Connector For Relay:Related Image20.6

~

50


Can be specified by
0.1m
increments
3
5
6
8
12
JSJS
(Female Relay / Female Relay)
Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
JPJS
(Male Relay / Female Relay)
Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
JPP
(Male for Relay /
Male Plug)
 Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
JSS
(Female for Relay /
Female Plug)
 Cable with R04 Connector For Relay:Related Image2
3
5
Connector6
8
12
JPS
(Male for Relay /
Female Plug)
 Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
JSP
(Female for Relay /
Male Plug)
 Cable with R04 Connector For Relay:Related Image2
3
5
6
8
12
Part Number
R04J-JPY-A-2-[0.2-50/0.1]
R04J-JPY-A-3-[0.2-50/0.1]
R04J-JPY-A-5-[0.2-50/0.1]
R04J-JPY-A-6-[0.2-50/0.1]
R04J-JPY-A-8-[0.2-50/0.1]
R04J-JPY-A-12-[0.2-50/0.1]
R04J-JPY-D-2-[0.2-50/0.1]
R04J-JPY-D-3-[0.2-50/0.1]
R04J-JPY-D-6-[0.2-50/0.1]
R04J-JPY-D-8-[0.2-50/0.1]
R04J-JPY-D-12-[0.2-50/0.1]
R04J-JPY-E-2-[0.2-50/0.1]
R04J-JPY-E-3-[0.2-50/0.1]
R04J-JPY-E-6-[0.2-50/0.1]
R04J-JPY-E-8-[0.2-50/0.1]
R04J-JPY-E-12-[0.2-50/0.1]
R04J-JPY-F-2-[0.2-50/0.1]
R04J-JPY-F-6-[0.2-50/0.1]
R04J-JPY-F-8-[0.2-50/0.1]
R04J-JPY-F-12-[0.2-50/0.1]
R04J-JSY-A-2-[0.2-50/0.1]
R04J-JSY-A-3-[0.2-50/0.1]
R04J-JSY-A-5-[0.2-50/0.1]
R04J-JSY-A-6-[0.2-50/0.1]
R04J-JSY-A-8-[0.2-50/0.1]
R04J-JSY-A-12-[0.2-50/0.1]
R04J-JSY-D-2-[0.2-50/0.1]
R04J-JSY-D-3-[0.2-50/0.1]
R04J-JSY-D-6-[0.2-50/0.1]
R04J-JSY-D-8-[0.2-50/0.1]
R04J-JSY-D-12-[0.2-50/0.1]
R04J-JSY-E-2-[0.2-50/0.1]
R04J-JSY-E-3-[0.2-50/0.1]
R04J-JSY-E-6-[0.2-50/0.1]
R04J-JSY-E-8-[0.2-50/0.1]
R04J-JSY-E-12-[0.2-50/0.1]
R04J-JSY-F-2-[0.2-50/0.1]
R04J-JSY-F-6-[0.2-50/0.1]
R04J-JSY-F-8-[0.2-50/0.1]
R04J-JSY-F-12-[0.2-50/0.1]
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipCN1 CN2 Number Of Cores Cable rated voltage
(V)
Shield Cable standard (UL/CSA) Cable color Twisted pair Environment resistant Bend tolerant Cable type #5

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[2] 2Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[3] 3Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[5] 5Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[6] 6Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal8Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal12Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[2] 21501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[3] 31501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[6] 61501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal81501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal121501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[2] 2300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[3] 3300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[6] 6300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal8300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal12300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[2] 23001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal[6] 63001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal83001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Male relay straightY terminal123001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[2] 2Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[3] 3Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[5] 5Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[6] 6Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal8Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal12Less than 1001 LayerN/AGrayN/AN/A-A0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[2] 21501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[3] 31501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[6] 61501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal81501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal121501 LayerULNavyIncludedOil-resistant-D0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[2] 2300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[3] 3300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[6] 6300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal8300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal12300N/AULBlackIncludedOil-resistant-E0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[2] 23001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal[6] 63001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal83001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

-

1 Piece(s) 8 Day(s) or more Female relay straightY terminal123001 LayerULBlackIncludedOil-resistant-F0.2 ~ 50

Loading...

  1. 1

Material / Finish

Item Materials Finish
Body Shell Brass and Zinc Alloy Nickel-plated
Contact Copper Alloy Nickel Base Gold Plating
Insulator Synthetic Resin -


Contact Arrangement Diagram


Mechanical Properties

Item Contents
Impact Resistance Acceleration 50 G
Vibration Resistance JIS C 5402, 6.1, 10 ~ 55 Hz, 10 G
Humidity Resistance JIS C 5402, 7.3, 40 ±2°C, 90% ~ 95% or less, 96 Hours
Corrosion Resistance JIS C 5402, 7.1, Salt Water Concentration 5%, 48 Hours
Operating Temperature Range -25°C ~ +85°C, Relative Humidity 85% or less
Temperature Cycle JIS C 5402, 7.2, -40°C ~ +100°C, 5 Cycles
Repeated Operation 1,000 Insertions and Removals
Waterproofing Water Pressure = 200kpa (When Coupled)

Compatible Wire Size

Conductor Cross-Sectional Area (mm2) AWG
Wire Size 0.2 ~ 0.05 24 ~ 30

* Be sure that the finished cable outer diameter is within the inner diameter of the cable extraction port of the connector.

Electrical Properties

Number of Cores Rated Voltage (V or less) Rated Current (A or less) Withstand Voltage
(VAC or less for 1 minute)
Insulation Resistance Contact Resistance Insertion and Removal Life
AC DC
2 300 420 2 900 1,000 MΩ or more
(500 VDC)
8 mΩ or less
(3 VDC, 1A or less)
1,000 times or more
3 300 420 2 900
5 150 200 2 500
6 300 420 2 900
8 200 280 2 700
12 300 420 2 900

* Rating represents the current capacity per contact core.

Panel Cut Size Drawing

* Mount all types from the front of the panel.

Wiring Method


Combination Method

Basic Information

Connector type R04 Connector manufacturer Tajimi Electronics Cable shape Circular
Conductor dimensions(AWG) 25