(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
Part | Material | Surface Treatment |
Bracket | Carbon Steel | Electroless Nickel Plating |
Case | Resin | - |
Type | Rated Pressure Range | Output Form | Mounting Method |
E-MKP | M(Positive Pressure - 0.1MPa~1MPa) V(Negative Pressure - 100kPa~0kPa) | N(2NPN Output+Analog Voltage Output) P(2PNP Output+Analog Voltage Output) | P(Panel) L(Bracket) |
Type | Positive Pressure Type(M) | Negative Pressure Type(V) | |
Rated Pressure Range | 0~1.0MPa | -100~0kPa | |
Set Pressure Range | -0.1~1.0MPa | -101.3~+10kPa | |
Withstanding Pressure | 1.5MPa | 300kPa | |
Gas Used | Air, non-corrosive, non-combustible gas | ||
Pressure Unit Setting Minimum Scale | kPa | - | 0.1 |
MPa | 0.001 | - | |
kgf/cm2 | 0.01 | 0.001 | |
bar | 0.01 | 0.001 | |
psi | 0.1 | 0.01 | |
inHg | - | 0.1 | |
mmHg | - | 1 | |
Power Voltage | DC12V~24V ±10%, continuous peak wave 10% or less | ||
Current Consumption | ≤40mA or less (without load) | ||
Sensor Output | <NPN Output Type> NPN Open Collector Transistor ・Maximum Inflow Current: 125mA ・Maximum Supply Voltage: 30V DC ・Internal Voltage Drop: 1.5V or less | <PNP Output Type> PNP Open Collector Transistor ・Maximum Source Current: 125mA ・Maximum Supply Voltage: 24V DC ・Internal Voltage Drop: 1.5V or less | |
Repetition Accuracy | ±0.2% F.S. ±1 digit or less | ||
Response Time | ≤2.5ms (false-operation prevention function: 25ms, 100ms, 250ms, 500ms, 1000ms, 1500ms selectable) | ||
Output Short Circuit Protection | Provided | ||
Display | 3 colors (red/green/orange) display (sampling rate: 5 times/second) | ||
Display Accuracy | ±2% F.S. ±1 digit (at ambient temperature: 25±3℃) | ||
Operation Display Light | Orange (1&2 indicator) OUT1 OUT2 | ||
Analog Output (Voltage Output) | Output Voltage | 1~5V ±2.5% F.S. (Within rated pressure range) | |
Linearity | ±1% F.S. | ||
Output Impedance | About 1kΩ | ||
Environment Resistance | Protection Rating | IP 40 | |
Ambient Temperature | Operation: 0~50℃, Storage: -10~60℃ (no dew condensation, no freezing) | ||
Ambient Humidity | Operation & Storage: 35~85%RH (no dew condensation) | ||
Withstand Voltage | 1000V AC 1 minute (between lead wire and plastic case) | ||
Insulation Impedance | 50MΩ or more (500 VDC) (between lead wire and plastic case) | ||
Temperature Characteristics | ±2.5% F.S. comparison reference temperature 25°C (with the temperature range of 0~50°C) | ||
Wire Specifications | Oil-resistant PVC wire (0.15mm2) |
Part Number |
---|
E-MKP-M-N-L |
E-MKP-M-N-P |
E-MKP-M-P-L |
E-MKP-M-P-P |
E-MKP-V-N-L |
E-MKP-V-N-P |
E-MKP-V-P-L |
E-MKP-V-P-P |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Rated Pressure (Max.) | Rated Pressure (Min.) | Output Method | Pressure Type | Pressure Resistant (MPa) | Mounting Method |
---|---|---|---|---|---|---|---|---|---|---|
₹ 2,164.00 | 1 Piece(s) | Available | 8 Day(s) | 1MPa | 0.1MPa | NPN Open Collector | Standard | 1.5MPA | Bracket mount | |
₹ 2,005.00 | 1 Piece(s) | Available | 8 Day(s) | 1MPa | 0.1MPa | NPN Open Collector | Standard | 1.5MPA | Panel mount | |
₹ 2,164.00 | 1 Piece(s) | Available | 8 Day(s) | 1MPa | 0.1MPa | PNP Open Collector | Standard | 1.5MPA | Bracket mount | |
₹ 2,005.00 | 1 Piece(s) | Available | 8 Day(s) | 1MPa | 0.1MPa | PNP Open Collector | Standard | 1.5MPA | Panel mount | |
₹ 2,164.00 | 1 Piece(s) | Available | 8 Day(s) | 100kPa | 0kPa | NPN Open Collector | Vacuum Pressure | 300KPA | Bracket mount | |
₹ 2,005.00 | 1 Piece(s) | Available | 8 Day(s) | 100kPa | 0kPa | NPN Open Collector | Vacuum Pressure | 300KPA | Panel mount | |
₹ 2,164.00 | 1 Piece(s) | Available | 8 Day(s) | 100kPa | 0kPa | PNP Open Collector | Vacuum Pressure | 300KPA | Bracket mount | |
₹ 2,005.00 | 1 Piece(s) | Available | 8 Day(s) | 100kPa | 0kPa | PNP Open Collector | Vacuum Pressure | 300KPA | Panel mount |
Loading...
Part | Material | Surface Treatment |
Bracket | Carbon Steel | Electroless Nickel Plating |
Case | Resin | - |
Type | Rated Pressure Range | Output Form | Mounting Method |
E-MKP | M(Positive Pressure - 0.1MPa~1MPa) V(Negative Pressure - 100kPa~0kPa) | N(2NPN Output+Analog Voltage Output) P(2PNP Output+Analog Voltage Output) | P(Panel) L(Bracket) |
Type | Positive Pressure Type(M) | Negative Pressure Type(V) | |
Rated Pressure Range | 0~1.0MPa | -100~0kPa | |
Set Pressure Range | -0.1~1.0MPa | -101.3~+10kPa | |
Withstanding Pressure | 1.5MPa | 300kPa | |
Gas Used | Air, non-corrosive, non-combustible gas | ||
Pressure Unit Setting Minimum Scale | kPa | - | 0.1 |
MPa | 0.001 | - | |
kgf/cm2 | 0.01 | 0.001 | |
bar | 0.01 | 0.001 | |
psi | 0.1 | 0.01 | |
inHg | - | 0.1 | |
mmHg | - | 1 | |
Power Voltage | DC12V~24V ±10%, continuous peak wave 10% or less | ||
Current Consumption | ≤40mA or less (without load) | ||
Sensor Output | <NPN Output Type> NPN Open Collector Transistor ・Maximum Inflow Current: 125mA ・Maximum Supply Voltage: 30V DC ・Internal Voltage Drop: 1.5V or less | <PNP Output Type> PNP Open Collector Transistor ・Maximum Source Current: 125mA ・Maximum Supply Voltage: 24V DC ・Internal Voltage Drop: 1.5V or less | |
Repetition Accuracy | ±0.2% F.S. ±1 digit or less | ||
Response Time | ≤2.5ms (false-operation prevention function: 25ms, 100ms, 250ms, 500ms, 1000ms, 1500ms selectable) | ||
Output Short Circuit Protection | Provided | ||
Display | 3 colors (red/green/orange) display (sampling rate: 5 times/second) | ||
Display Accuracy | ±2% F.S. ±1 digit (at ambient temperature: 25±3℃) | ||
Operation Display Light | Orange (1&2 indicator) OUT1 OUT2 | ||
Analog Output (Voltage Output) | Output Voltage | 1~5V ±2.5% F.S. (Within rated pressure range) | |
Linearity | ±1% F.S. | ||
Output Impedance | About 1kΩ | ||
Environment Resistance | Protection Rating | IP 40 | |
Ambient Temperature | Operation: 0~50℃, Storage: -10~60℃ (no dew condensation, no freezing) | ||
Ambient Humidity | Operation & Storage: 35~85%RH (no dew condensation) | ||
Withstand Voltage | 1000V AC 1 minute (between lead wire and plastic case) | ||
Insulation Impedance | 50MΩ or more (500 VDC) (between lead wire and plastic case) | ||
Temperature Characteristics | ±2.5% F.S. comparison reference temperature 25°C (with the temperature range of 0~50°C) | ||
Wire Specifications | Oil-resistant PVC wire (0.15mm2) |
Type | Pressure Sensors | Fluid Type | Air / Nitrogen Gas / Carbon Dioxide Gas | Sensor, Monitor Structure | Integrated Type |
---|---|---|---|---|---|
Pipe Port Type | Nipples | Plumbing Thread Type | M | Plumbing Thread Nominal | M5x0.8 |
Fluid Characteristics | Non-Corrosivity / Non-combustibility / Inertness | Operating Temperature Range(°C) | 0::50 | Operating Humidity Range(%) | 35::85 |
Power Supply Type | DC | Power Supply Voltage(V) | 12~24 | Hysteresis(%FS) | ±2.5 |
Pipe Connection Direction | Back | Mounting Holes | Provided | Display | Digital |
Drive Component | Digital | Lamp | Provided | IP | IP40 |
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy