(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Thermocouples(Thermocouples type:J type)

Thermocouples products in the Plastic Mold Components category. Specified by Thermocouples type J type. There are around 2 items of Thermocouples products available and the specifications can easily be compared. Plastic Molding Parts and accessories. Thermocouples offers a wide selection of products, on time delivery, free shipping and no minimum order quantity with a consulting team available.
CAD
Days to Ship
  • All
  • Same day
  • 6 Day(s) or Less

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Sheathed Thermocouples

    Sheathed Thermocouples

    MISUMI

    [Specifications]
    -Type: K type, J type
    -Tip shape: Non-grounded type
    -Tolerance class: Class 2
    When installing, please also use the mounting jig for sheath thermocouples.

    • Volume Discount
    CAD :
    2D / 3D
    Thermocouples type How to mount Max. temperature(℃) Brand
    J type Jig 450 ~ 750 -
    From: ₹ 3,068.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-

    Sheathed Thermocouples -Spring Attachment Type-

    MISUMI

    [Features]
    Easy installation and removal
    Thermocouple Type•K type Blue Color•J type Yellow Color
    Tolerance class: Class 2

    • Volume Discount
    CAD :
    2D / 3D
    Thermocouples type How to mount Max. temperature(℃) Brand
    J type Spring attachment 300 -
    From: ₹ 5,227.00
    Days to Ship: Same day
    day to ship Same day
Brand
Product Series
CAD
From
Days to Ship
Thermocouples type
How to mount
Max. temperature(℃)
Brand

    You can add up to 6 items per a category to the compare list.

    Sheathed Thermocouples

        You can add up to 6 items per a category to the compare list.

        Sheathed Thermocouples -Spring Attachment Type-
          Sheathed Thermocouples -Spring Attachment Type-
          Sheathed Thermocouples -Spring Attachment Type-
          Sheathed Thermocouples -Spring Attachment Type-
          Sheathed Thermocouples -Spring Attachment Type-
          Brand

          MISUMI

          MISUMI

          Product Series

          Sheathed Thermocouples

          Sheathed Thermocouples -Spring Attachment Type-

          CAD
          • 2D / 3D
          • 2D / 3D
          From

          ₹ 3,068.00

          ₹ 5,227.00

          Days to Ship Same day or more Same day
          Thermocouples typeJ typeJ type
          How to mountJigSpring attachment
          Max. temperature(℃)450 ~ 750300
          Brand--

          Loading...

          1. 1

          Related Categories to Thermocouples

          FAQ Thermocouples

          Question: What are the types of thermocouples and their temperature range?
          Answer: Common thermocouple types include:
          Type K: General-purpose, wide range, temperature range -200°C to 1350°C
          Type J: Suitable for lower temperatures, temperature range -40°C to 750°C
          Type T: Best for low-temperature measurements, temperature range -200°C to 350°C
          Type E: High accuracy and sensitivity, temperature range -200°C to 900°C
          Type N: High temperature, better oxidation resistance, temperature range -200°C to 1300°C
          Question: How do I select the right thermocouple for my application?
          Answer: Consider the following factors to select the right thermocouple:
          Temperature range: Ensure the thermocouple can withstand the temperature of your environment.
          Material compatibility: Some thermocouple materials work better in certain environments (e.g., corrosive or oxidizing atmospheres).
          Accuracy and sensitivity needs: Different types have varying levels of sensitivity and accuracy.
          Environment: Ensure your thermocouple can withstand vibrations, pressure, or moisture if needed.
          Question: What causes a thermocouple to fail?
          Answer: Common causes of thermocouple failure include:
          • Mechanical damage
          • Exposure to extreme temperatures beyond its rating
          • Oxidation or corrosion
          • Electrical short circuits
          • Metal fatigue
          Question: What are the different types of thermocouple signal conditioners?
          Answer: Analog signal conditioners: Convert the thermocouple voltage into an analog output (e.g., 4-20 mA current loop).
          Digital signal conditioners: Convert the thermocouple voltage into a digital signal (e.g., RS-232, USB).
          Integrated signal conditioners: Combine analog and digital functions in a single unit.
          X
          whatsapp-qr whatsapp-icon