(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Brand |
|
---|---|
CAD |
|
Days to Ship |
|
39 items
You can add up to 6 items per a category to the compare list.
URD
Medium to high frequency band current transformer (CT). Highest 500kHz/200A can detect current without contact, and is almost no load to the current line.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.02~200 | Alternating Current (AC) | 24 | Not Fixed |
From: ₹ 4,844.95 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
High reliability with sensor/ amplifier integrated structure. Can measure insulation.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
-800~800 ~ -10~10 | DC | 20 ~ 36 | Panel Mounting |
From: ₹ 7,146.02 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· Zero flux type current sensor composed of an iron core, a hall element, and a feedback coil.
· Integrated sensor / amplifier structure is highly reliable.
· From DC 500KHz excellent linearity with wide frequency band.
Fast response within 1.5 μs.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
-250~250 ~ -25~25 | DC | 20 | Not Fixed |
From: ₹ 15,091.31 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
AC non-power supply sensor and power ON detection circuit package as all in one structure.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
2~50 | Alternating Current (AC) | 8.5X17.5 | Panel Mounting |
From: ₹ 7,071.02 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Average value rectifier current converter, sensor-converter integrated current converter 10A to 50A
URD
[Features]
· Average value rectification type current converter of AC current detection · DC voltage output.
· Integrated sensor / converter structure is highly reliable.
· Externally attached circuit not required.
· Can measure insulation.
· 1: 100 Excellent linearity within this range
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0~20 ~ 0~50 | Alternating Current (AC) | 8.5X17.5 | Panel Mounting |
From: ₹ 6,399.98 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· Commercial power supply 50/60Hz dedicated AC current detection/ average value rectification current converter of DC voltage output
· No power supply required sensor 0-5VDC direct output of instrumentation signal.
· Mounting is extremely simple with clamp type sensor/ converter integrated type.
· Can measure insulation.
· From 0 to 5A and from 0 to 500A corresponds to wide range of current.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0~5 ~ 0~500 | Alternating Current (AC) | 10 ~ 36 | Not Fixed |
From: ₹ 3,966.29 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Split/Clamp Type Sensor, Clamp Type AC Current Sensor
URD
Smallest type in clamp type sensor. Nylon spring / one-touch clamp type that is easily installable on existing equipment.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.01~15 ~ 0.1~500 | Alternating Current (AC) | 6 ~ 36 | Not Fixed |
From: ₹ 1,898.12 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
General purpose type for general industrial machines such as heater and motor etc. Best seller models have proudly reached the production cumulative total of 1 million or more.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~80 | Alternating Current (AC) | 5.8 | Mounting of Substrate |
From: ₹ 1,615.65 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL General-purpose Series AC Current Sensor for PCB and Panel Mounting Used for General Measurement
URD
Standard product of medium size current sensor with through hole diameter ø12. 40 mm square compact shape, maximum 280A most versatile current sensor that covers the wide range.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~280 ~ 0.1~320 | Alternating Current (AC) | 12 | Mounting of Substrate |
From: ₹ 1,988.02 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL general-purpose series output lead wire type AC current sensor for general gauge
URD
Medium size current sensor with through hole diameter ø12. Lead wire type fully compatible with standard products and performance. 40 mm square compact shape, maximum 280A most versatile current sensor that covers the wide range.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~280 ~ 0.1~300 | Alternating Current (AC) | 12 | Not Fixed |
From: ₹ 1,967.93 |
---|
Days to Ship: 9 Day(s) or more |
You can add up to 6 items per a category to the compare list.
General-Purpose DC Current Sensor, Split Type for Panel Mounting / ±15 V Power Supply Compatible
URD
Sensor / amplifier integrated structure/ split mounting type. Can measure insulation.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
-800~800 ~ -10~10 | DC | 20 ~ 36 | Panel Mounting |
From: ₹ 10,621.75 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Commercial power supply 50 /60Hz detects the distorted waveform as the effective value. Clamp type sensor/ extremely easy to install with integrated converter.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0~5 ~ 0~500 | Alternating Current (AC) | 16 ~ 36 | Not Fixed |
From: ₹ 10,124.84 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Mounting bracket for the current sensor
URD
Width W (ø) Height H (ø) Width W (mm) = 84 × 15.5 × 4 or 20 × 22.6 × 9.35. Mounting bracket for current sensor. Available for purchase by single unit
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
- | - | - | - |
From: ₹ 478.51 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL-Z Series for Precise MeasurementSensor Attached on Printed Circuit Board
URD
[Features]
· Straight pins for printed board horizontal mounting
· For general measurement CTL-Z smallest model of the series.
· Secure through hole (ø6) for ultra small product.
· With weight about 5 g, suitable for assembly method of directly loading on printed circuit board with integrated conductor.
· Adopting high permeability permalloy core, 1mA to 15A covers wide range.
· 800: 1 Direct interface to electronic circuit is possible at high current variable.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.001~15 | Alternating Current (AC) | 6 | Mounting of Substrate |
From: ₹ 2,092.49 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Current transformer (CT) of small and high frequency band. Highest 1MHz/60A can detect current without contact, and is almost no load to the current line.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.01~60 | Alternating Current (AC) | 5.8 | Panel Mounting |
From: ₹ 3,106.40 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Medium to high frequency band current transformer (CT). Highest 500kHz/200A can detect current without contact, and is almost no load to the current line.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.01~200 | Alternating Current (AC) | 12 | Mounting of Substrate |
From: ₹ 4,223.45 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· +12V Single power supply compatible
· Since the output varies in the range of 0.5 to 4.5 V while centered around 2.5 V, direction interruption is possible.
· Can measure insulation.
· DC to 20KHz Measurement of high frequencies bands is possible (in case of using high frequencies it may not be possible to use rated current).
· no destruction even with over current (within the maximum pulse width).
· Fast response within 3 μs (however, for continuous use, do not exceed the rated current).
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
-25~25 ~ -3~3 | DC | - | Mounting of Substrate |
From: ₹ 2,675.13 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Integrated sensor / amplifier structure is highly reliable. Can measure insulation.
[Features]
· Integrated sensor / amplifier structure is highly reliable.
· Can measure insulation.
· DC to 20KHz measurement of high frequencies bands is possible (in case of using high frequencies it may not be possible to use rated current).
· Fast response within 3 μs
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
-500~500 ~ -50~50 | DC | 20 ~ 36 | Panel Mounting |
From: ₹ 7,393.80 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL common use series for general measurement, printed circuit board current sensor
URD
[Features]
■ CTL-6-L
· Straight pins for printed board horizontal mounting.
· For general measurement CTL smallest model of general series.
· Secure through hole (ø6) for ultra small product.
· With weight about 5 g, suitable for assembly method of directly loading on printed circuit board with integrated conductor.
· compatible with CT external type. Applied current maximum 40A covers wide range.
· 800: 1 Direct interface to electronic circuit is possible at high current variable.
CTL-6-V
· Right angle pin for vertical mounting of printed board.
· For general measurement CTL smallest model of general series.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~40 | Alternating Current (AC) | 6 | Mounting of Substrate |
From: ₹ 1,615.65 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL general purpose series AC current sensor for mounting panel for general measurement
URD
[Features]
· General purpose type for general industrial machines such as heater and motor etc.
· Best seller models have proudly reached the production cumulative total of 1 million or more (for panel mounting).
· Despite being a small product with a through hole diameter of ø5.8 and a weight of approximately 12 g, it is able to cover a wide range from 0.1 A to 80A.
· With a high current ratio of 800: 1, the secondary current is small, allowing direct interface to electronic circuits.
· # 110 standard tab is output terminal.
· Supports lead wire soldering
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~80 | Alternating Current (AC) | 5.8 | Panel Mounting |
From: ₹ 1,615.65 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL general-purpose series output lead wire mini type AC current sensor for general gauge.
URD
[Features]
· General purpose/ applied current to standard small current sensor and common number of windings 120A superior model with common extended electrical specifications.
· Small design with slim external shape and weight while securing through hole ø12.
· With an output lead wire type, any connector or cable extension connection is easy.
· Pin terminal structure for PC board mounting, OEM available by handling
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~120 ~ 0.1~180 | Alternating Current (AC) | 12 | Not Fixed |
From: ₹ 1,720.13 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· While being 38 × 38 mm compact design, it has compact current sensor with high versatility securing the through hole diameter of ø18.
· High current ratio (3000: 1) the secondary current is small, allowing direct interface to electronic circuits.
· 0.1 to 180Arms excellent linearity in the range.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~180 | Alternating Current (AC) | 18 | Not Fixed |
From: ₹ 2,112.58 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Large diameter of through hole diameter ø24, standard product with medium size current sensor. Maximum 320A corresponds to large current.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~320 | Alternating Current (AC) | 24 | Not Fixed |
From: ₹ 2,484.93 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Large diameter of through hole diameter ø36, large standard current sensor. Maximum load current 800A for general measurement CTL Top most model for general purpose series.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.1~800 | Alternating Current (AC) | 36 | Panel Mounting |
From: ₹ 4,575.73 |
---|
Days to Ship: 9 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL-Z Series for Precise Measurement AC Sensor Attached on Printed Circuit Board
URD
[Features]
· Compact standard sensor for precision measurement (compatible with printed board).
· Adopts a high permeability permalloy core. Covers a wide range of 1mA to 20A.
· With a high current ratio of 800: 1, the secondary current is small, allowing direct interface to electronic circuits.
· # 110 standard tab is output terminal.
· Correspond to both printed circuit board soldering/ lead wire soldering.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.001~20 | Alternating Current (AC) | 5.8 | Mounting of Substrate |
From: ₹ 2,092.49 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL-Z Series for Precise MeasurementPanel Mount AC Sensor
URD
[Features]
· A standard small sensor (panel mounted compatible type) for precision measurement. Adopts a high permeability permalloy core. Covers a wide range of 1mA to 20A.
· With a high current ratio of 800: 1, the secondary current is small, allowing direct interface to electronic circuits.
· # 110 standard tab is output terminal.
· Lead wire soldering can be used for either case.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.001~20 | Alternating Current (AC) | 5.8 | Panel Mounting |
From: ₹ 2,112.58 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
CTL-Z Series Alternating Current Sensor for Precision Measurement
URD
[Features]
· Medium standard sensor for precision measurement with a through hole diameter ø12.
· Adopting high permeability permalloy core 1mA to 100A covers wide range.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.0005~100 ~ 0.001~200 | Alternating Current (AC) | 12 | Mounting of Substrate |
From: ₹ 2,857.27 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Precision measurement for CTL-Z Series Large-diameter, Alternating Current Sensor
URD
[Features]
■ CTL-24-S28-10Z
· large diameter of through hole diameter ø24, standard size sensor for precise measurement.
· Adopts a high permeability permalloy core. Covers a wide 1mA to 80A.
· With a high current ratio of 1000: 1, the secondary current is small, allowing direct interface to electronic circuits.
· Output lead wire is a vinyl wire (0.3 mm² × 100l).
· Mounting bracket sold separately for panel mounting (HLD-24) are customized.
■ CTL-24-S28-20Z
· An expanded capacity type that has increased the secondary coil of the standard product for precision measurement (CTL-24-S28-10Z). Features a large diameter through hole of ø24. It also features an expanded applied current range of 1mA to 280A.
· With a high current ratio of 2000: 1, the secondary current is small, allowing direct interface to electronic circuits.
· Dimensions fully compatible with standard products.
· Output lead wire is a vinyl wire (0.3 mm² × 100l).
· Mounting bracket sold separately for panel mounting (HLD-24) are customized.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.001~80 ~ 0.001~280 | Alternating Current (AC) | 24 | Not Fixed |
From: ₹ 3,209.55 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· universal type / multi functional current sensor based on a combination of ferrite core and high current ratio.
· Due to the high current ratio CT, it is possible to obtain a high output voltage despite its small size.
· Good output linearity from a minute current of 1mA to 1 A, to a large current range of 1 A to 80A
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.001~80 | Alternating Current (AC) | 8.5X17.5 | Panel Mounting |
From: ₹ 2,092.49 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Division, Clamp Model Sensor/Clamp AC Sensor for Broadband and Earth Line Monitors
URD
[Features]
· A single-action clamp type CT with a through hole diameter of ø22 that can be attached to ground wires of up to 100 mm.
· Boasts an ultra wide range of 1mA to 120A, through which good output linearity can be obtained.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.001~120 | Alternating Current (AC) | 21.5±0.5 | Not Fixed |
From: ₹ 4,223.45 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· For small current transformer (CT) and light emitting display LED sealed in integral case.
· Simply piercing the electric wire through which the alternating current flows into the hole in the center, the power ON condition can be easily monitored and is reliable.LED in an indicator.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
1~20 | Alternating Current (AC) | 5.8 | Not Fixed |
From: ₹ 1,615.65 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
±15V supports controlled power supply, for output direction identification at ± 4 V. Can measure insulation.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
-25~25 ~ -0.1~0.1 | DC | - | Mounting of Substrate |
From: ₹ 2,675.13 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· Sensor, split type integrated amplifier, wire one-touch clamp structure.
· Can measure insulation.
· ±15V Power supply compatible, direction interruption is possible with ± voltage output.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
-500~500 ~ -50~50 | DC | 10 ~ 36 | Not Fixed |
From: ₹ 8,684.98 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· All-in-one structure integrated current detection circuit in a clamp type AC current sensor.
· Power ON detection signal can be obtained merely by clamping to the power line with no power supply.
· High sensitivity type and operating points 1A of fixed operating point 1.0 A 10A,10 to 100A 3 setting types are standardized.
· In response to small current of less than 1.0A rated, sensitivity is multiplied by (n) when the detection wire in the sensor takes (n) turn.
· 50Hz/60Hz sinusoidal wave specific (operating point changes with waveform distortion)
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
1~10 ~ 10~100 | Alternating Current (AC) | 16 | Not Fixed |
From: ₹ 6,201.75 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Over-current warning machine to detect abnormalities of various electronic devices, motor overload / partial short circuit of heater.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.2~20 | Alternating Current (AC) | - | DIN Rail Mounting |
From: ₹ 9,752.47 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· Over-current warning machine to detect abnormalities of various electronic devices, motor overload / partial short circuit of heater.
· In the structure that does not require externally controlled power supply, it is compatible to large current type with an external sensor attached.
· Power supply is, 100V/200V can be shared with taps.
· Operating point is, 5A to 200A accurate overload can be detected using programming method.
· The dead zone timer prevents malfunction till current settling for motor startup current, and for starting mode such as magnetizing inrush current of transformer.
· Operation display LED including operation point setting is easy.
· Alarm output is non-voltage 1 transfer contact.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
5~200 | Alternating Current (AC) | - | DIN Rail Mounting |
From: ₹ 11,615.58 |
---|
Days to Ship: 10 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
Method to distinguish it as disconnection when there is voltage but insufficient current. All-in-one structure that requires no external control power supply.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.2~20 | Alternating Current (AC) | - | DIN Rail Mounting |
From: ₹ 9,802.04 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
[Features]
· Method to distinguish it as disconnection in case of insufficient voltage and insufficient current (does not supporting cycle control).
· With no externally controlled power supply, it supports external sensor having small current.
· Power supply is, 100V/200V can be shared with taps.
· Operating point is, 0.5A to 20A can be set by programming method.
· Operation display LED including operation point setting is easy.
· Alarm output is non-voltage 1 transfer contact.
· Standard item with built-in CT (CRY-CP) compatible with CT external type.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
0.5~20 | Alternating Current (AC) | - | DIN Rail Mounting |
From: ₹ 12,484.84 |
---|
Days to Ship: 11 Day(s) or more |
You can add up to 6 items per a category to the compare list.
URD
3 m black and white twisted cable (tip 5 mm cut off), extension cable for current sensors. It can be purchased separately.
Applicable Current(A) | Input Current | Through Hole(φ) | Mounting Method |
---|---|---|---|
- | - | - | - |
From: ₹ 664.69 |
---|
Days to Ship: 9 Day(s) or more |
Brand |
---|
Product Series |
From |
Days to Ship |
Applicable Current(A) |
Input Current |
Through Hole(φ) |
Mounting Method |
You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | |
Brand | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD | URD |
Product Series | Average value rectifier current converter, sensor-converter integrated current converter 10A to 50A | CTL General-purpose Series AC Current Sensor for PCB and Panel Mounting Used for General Measurement | CTL general-purpose series output lead wire type AC current sensor for general gauge | General-Purpose DC Current Sensor, Split Type for Panel Mounting / ±15 V Power Supply Compatible | CTL-Z Series for Precise MeasurementSensor Attached on Printed Circuit Board | CTL common use series for general measurement, printed circuit board current sensor | CTL general purpose series AC current sensor for mounting panel for general measurement | CTL general-purpose series output lead wire mini type AC current sensor for general gauge. | CTL-Z Series for Precise Measurement AC Sensor Attached on Printed Circuit Board | CTL-Z Series Alternating Current Sensor for Precision Measurement | Precision measurement for CTL-Z Series Large-diameter, Alternating Current Sensor | Division, Clamp Model Sensor/Clamp AC Sensor for Broadband and Earth Line Monitors | |||||||||||||||||||||||||||
From | ₹ 4,844.95 | ₹ 7,146.02 | ₹ 15,091.31 | ₹ 7,071.02 | ₹ 6,399.98 | ₹ 3,966.29 | ₹ 1,898.12 | ₹ 1,615.65 | ₹ 1,988.02 | ₹ 1,967.93 | ₹ 10,621.75 | ₹ 10,124.84 | ₹ 478.51 | ₹ 2,092.49 | ₹ 3,106.40 | ₹ 4,223.45 | ₹ 2,675.13 | ₹ 7,393.80 | ₹ 1,615.65 | ₹ 1,615.65 | ₹ 1,720.13 | ₹ 2,112.58 | ₹ 2,484.93 | ₹ 4,575.73 | ₹ 2,092.49 | ₹ 2,112.58 | ₹ 2,857.27 | ₹ 3,209.55 | ₹ 2,092.49 | ₹ 4,223.45 | ₹ 1,615.65 | ₹ 2,675.13 | ₹ 8,684.98 | ₹ 6,201.75 | ₹ 9,752.47 | ₹ 11,615.58 | ₹ 9,802.04 | ₹ 12,484.84 | ₹ 664.69 |
Days to Ship | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 9 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 9 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 10 Day(s) or more | 5 Day(s) or more | 11 Day(s) or more | 9 Day(s) or more |
Applicable Current(A) | 0.02~200 | -800~800 ~ -10~10 | -250~250 ~ -25~25 | 2~50 | 0~20 ~ 0~50 | 0~5 ~ 0~500 | 0.01~15 ~ 0.1~500 | 0.1~80 | 0.1~280 ~ 0.1~320 | 0.1~280 ~ 0.1~300 | -800~800 ~ -10~10 | 0~5 ~ 0~500 | - | 0.001~15 | 0.01~60 | 0.01~200 | -25~25 ~ -3~3 | -500~500 ~ -50~50 | 0.1~40 | 0.1~80 | 0.1~120 ~ 0.1~180 | 0.1~180 | 0.1~320 | 0.1~800 | 0.001~20 | 0.001~20 | 0.0005~100 ~ 0.001~200 | 0.001~80 ~ 0.001~280 | 0.001~80 | 0.001~120 | 1~20 | -25~25 ~ -0.1~0.1 | -500~500 ~ -50~50 | 1~10 ~ 10~100 | 0.2~20 | 5~200 | 0.2~20 | 0.5~20 | - |
Input Current | Alternating Current (AC) | DC | DC | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | DC | Alternating Current (AC) | - | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | DC | DC | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | DC | DC | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | Alternating Current (AC) | - |
Through Hole(φ) | 24 | 20 ~ 36 | 20 | 8.5X17.5 | 8.5X17.5 | 10 ~ 36 | 6 ~ 36 | 5.8 | 12 | 12 | 20 ~ 36 | 16 ~ 36 | - | 6 | 5.8 | 12 | - | 20 ~ 36 | 6 | 5.8 | 12 | 18 | 24 | 36 | 5.8 | 5.8 | 12 | 24 | 8.5X17.5 | 21.5±0.5 | 5.8 | - | 10 ~ 36 | 16 | - | - | - | - | - |
Mounting Method | Not Fixed | Panel Mounting | Not Fixed | Panel Mounting | Panel Mounting | Not Fixed | Not Fixed | Mounting of Substrate | Mounting of Substrate | Not Fixed | Panel Mounting | Not Fixed | - | Mounting of Substrate | Panel Mounting | Mounting of Substrate | Mounting of Substrate | Panel Mounting | Mounting of Substrate | Panel Mounting | Not Fixed | Not Fixed | Not Fixed | Panel Mounting | Mounting of Substrate | Panel Mounting | Mounting of Substrate | Not Fixed | Panel Mounting | Not Fixed | Not Fixed | Mounting of Substrate | Not Fixed | Not Fixed | DIN Rail Mounting | DIN Rail Mounting | DIN Rail Mounting | DIN Rail Mounting | - |
Loading...
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy