TOYOZUMI Transformers

Transformers products in the Electrical & Controls category from TOYOZUMI. The product can be selected based on many product specifications such as Primary voltage, Capacity, Secondary voltage, Number of phases/winding, Insulation type. TOYOZUMI offers products around 5 items and the product specifications can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies TOYOZUMI products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 12 Day(s) or Less
  • 13 Day(s) or Less
  • 15 Day(s) or Less
  • Others

5 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Single-Phase Multiple-Winding Transformer, SD21 Series

    Single-Phase Multiple-Winding Transformer, SD21 Series

    TOYOZUMI

    Here is the 200V switching to 100V step-down transformer. For all equipment types P-S gap shield is attached. It is made to prevent power supply noise.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    240 0.05 ~ 5 115 Single-phase/Double-winding A type / B Type Screw terminal block 80 ~ 224.5 Available NA 79 ~ 224 94 ~ 247
    From: ₹ 6,571.47
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Single-Phase Single-Winding Transformer AD21 Series

    Single-Phase Single-Winding Transformer AD21 Series

    TOYOZUMI

    Here is the 200V switching to 100V step-down transformer. Insulation between input and output is unneeded. Therefore it is best for customers who want to decrease the space control panel is taking.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    240 0.05 ~ 5 115 Single-phase/single-winding A type / B Type Screw terminal block 71 ~ 172 NA NA 68 ~ 178 86 ~ 186
    From: ₹ 4,390.93
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Single-Phase Multiple-Winding Transformer, LD21 Series

    Single-Phase Multiple-Winding Transformer, LD21 Series

    TOYOZUMI

    Step-down transformer for 200V switching to 100V. We have reached the low-cost goal while maintaining the quality of a Toyozumi production SD21 series. For all equipment types, gap shield is included in P-S to best prevent interference.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    220 0.05 ~ 5 110 Single-phase/Double-winding E Type / F type Screw terminal block 81 ~ 209 Available NA 68 ~ 224 86 ~ 247
    From: ₹ 4,708.36
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Portable / Case-Included Step-Up Transformer, CU-S Series

    Portable / Case-Included Step-Up Transformer, CU-S Series

    TOYOZUMI

    When power voltage at 100V, it is convenient for using equipments of 110V, 115 to 120V, 220V, 230 to 240V. It is portable, which is perfect for using it while placing it temporarily.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    100 0.6 ~ 1 110 ~ 235 Single-phase/single-winding B Type Other 147 ~ 180 NA Available 94 ~ 144 149 ~ 188
    From: ₹ 17,571.91
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Portable Case Included, Step-Down Transformer, KS Series

    Portable Case Included, Step-Down Transformer, KS Series

    TOYOZUMI

    When power voltage at 200 V, it is convenient for using equipments of 100 V. It is portable, which is perfect for using it while placing it temporarily.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    200 0.6 ~ 1.5 100 Single-phase/single-winding B Type Other 164 ~ 180 NA Available 134 ~ 154 178 ~ 200
    From: ₹ 26,106.53
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
From
Days to Ship
Primary voltage(V)
Capacity(kVA)
Secondary voltage(V)
Number of phases/winding
Insulation type
Input/output terminal shape
Dimension vertical(mm)
Shield presence
With/without Case
Dimension width(mm)
Dimension depth(mm)

You can add up to 6 items per a category to the compare list.

Single-Phase Multiple-Winding Transformer, SD21 Series

    You can add up to 6 items per a category to the compare list.

    Single-Phase Single-Winding Transformer AD21 Series

      You can add up to 6 items per a category to the compare list.

      Single-Phase Multiple-Winding Transformer, LD21 Series

        You can add up to 6 items per a category to the compare list.

        Portable / Case-Included Step-Up Transformer, CU-S Series

          You can add up to 6 items per a category to the compare list.

          Portable Case Included, Step-Down Transformer, KS Series
            Brand

            TOYOZUMI

            TOYOZUMI

            TOYOZUMI

            TOYOZUMI

            TOYOZUMI

            Product Series

            Single-Phase Multiple-Winding Transformer, SD21 Series

            Single-Phase Single-Winding Transformer AD21 Series

            Single-Phase Multiple-Winding Transformer, LD21 Series

            Portable / Case-Included Step-Up Transformer, CU-S Series

            Portable Case Included, Step-Down Transformer, KS Series

            From

            ₹ 6,571.47-

            ₹ 4,390.93-

            ₹ 4,708.36-

            ₹ 17,571.91-

            ₹ 26,106.53-

            Days to Ship 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more
            Primary voltage(V)240240220100200
            Capacity(kVA)0.05 ~ 50.05 ~ 50.05 ~ 50.6 ~ 10.6 ~ 1.5
            Secondary voltage(V)115115110110 ~ 235100
            Number of phases/windingSingle-phase/Double-windingSingle-phase/single-windingSingle-phase/Double-windingSingle-phase/single-windingSingle-phase/single-winding
            Insulation typeA type / B TypeA type / B TypeE Type / F typeB TypeB Type
            Input/output terminal shapeScrew terminal blockScrew terminal blockScrew terminal blockOtherOther
            Dimension vertical(mm)80 ~ 224.571 ~ 17281 ~ 209147 ~ 180164 ~ 180
            Shield presenceAvailableNAAvailableNANA
            With/without CaseNANANAAvailableAvailable
            Dimension width(mm)79 ~ 22468 ~ 17868 ~ 22494 ~ 144134 ~ 154
            Dimension depth(mm)94 ~ 24786 ~ 18686 ~ 247149 ~ 188178 ~ 200

            Loading...

            1. 1

            Related Categories to Transformers

            FAQ Transformers

            Question: What is the difference between 1 phase transformers and 3 phase transformers.
            Answer: 1. In a single-phase transformer, the electricity is supplied through two wires called Line and neutral. In three phase transformers, the electricity is supplied through three wires (four wires if neutral wire is included).
            2. The voltage of single-phase transformer supply is 230V whereas three-phase transformer supply is 415V.
            3. The efficiency of a three-phase transformer is significantly higher than a single-phase supply and the power transfer capability is also more.
            Question: How many types of transformers?
            Answer: Type of transformer can be separated by different types of applications.
            1. Transformer types based on core structure.
               1.1) Iron core transformer
               1.2) Shell core transformer
               1.3) H-type core transformer
            2. Transformer types based on electric system.
               2.1) Single-phase transformer
               2.2) Three-phase transformer
            3. Transformer types based on voltage level.
               3.1) Step-up transformer which is use for boost voltage up then transmit to secondary side.
               3.2) Step-down transformer which is use for reducing voltage down then transmit to secondary side.
               3.3) Isolation transformer which voltage at primary and secondary side are same. Typically, applicable for Laboratory which is need stable voltage and current.
            Question: What is transformer maintenance method?
            Answer: 1. Should install and using in low-humidity to prevent short circuit issue.
            2. Installation place should be good for heat transfer.
            3. Always keep cleaning heat transfer component.
            4. Always keep inspection terminal and wire.
            Question: Why transformer is necessary?
            Answer: Transformers is necessary because each electric device need different level of voltage. So, we must use transformer to adjust the electrical voltage from power source to sub-unit. Such as, reduce voltage from high-power electric post to the building and transformer for reduce voltage level from electric source of building to each electrical home appliance as well.