(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

OMRON Limit Switch(Rated Operating Voltage:AC120/240V)

OMRON offers products Limit Switch specified by Rated Operating Voltage AC120/240V from Automation Components product category. There are a total of 3 items. Search and select detailed specifications of parts for your machine with free CAD downloads. OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 1 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • Others

3 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Small Solenoid Lock / Safety Door Switch [D4SL-N]

    Small Solenoid Lock / Safety Door Switch [D4SL-N]

    OMRON

    General-purpose enclosed switch with high shut-off capacity and high durability
    [Features]
    · ZE, ZV, and ZV2 types have built-in Z type general-purpose basic switch.
    · Highly durable and has a large shutoff capacity.
    · There are three types of mounting methods: side, bottom and side diagonal, as well as abundant actuator types.
    · Connecting is easy since the terminal of the built-in switch is on the front when the cover is removed.
    · Models with ground terminals support CE Marking.
    · UL/CSA/CCC certified (contact the manufacturer for the certification format).

    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    - Small Type Standard - - - - - - - - AC120/240V -
    From: ₹ 8,845.50
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Solenoid Lock / Safety Door Switch / Slide Key Unit [D4JL/D4JL-SK40]

    Solenoid Lock / Safety Door Switch / Slide Key Unit [D4JL/D4JL-SK40]

    OMRON

    Lock Strength 3,000 N
    [Features]
    · Various monitoring patterns can be used thanks to 2 circuits + 2 contacts in the safety circuit.
    · It uses gold clad contacts as standard and supports both general load and micro load. The trap key type helps avoid the danger of being left behind within the fence.
    · A rear release button type that allows unlocking from the inside and egress even when locked within the fence.
    · Protection degree IP67.

    CAD :
    2D / 3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    - Standard Standard - - - - - Mutually Insulated Double Throw - - AC120/240V 10
    From: ₹ 15,277.87
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Solenoid Lock / Safety Door Switch [D4BL]

    Solenoid Lock / Safety Door Switch [D4BL]

    OMRON

    After the cutting tool stops due to the inertia of the machine, unlock the protective cover using the controller signal, pushbutton switch, etc.
    [Features]
    · The mechanical lock automatically engages when the operation key is inserted. The mechanism releases the lock only when voltage is applied to the solenoid, realizing high safety.
    · It has acquired EN (TÜV) Standards compatible with CE Marking.
    · UL/CSA/CCC certified.
    · The direct circuit opening mechanism (NC contact side only) is used to open the switch contacts when opening the protective cover. The direct circuit opening certification by EN standards is displayed on the switch cover.
    · The release key handles maintenance power outages (power supply failures).
    · The main body is made of robust and strong aluminum die-cast, and the inside of the box has protection degree IP67, UL, CSA Type 6P, 13.
    · Also equipped with two conduit ports in horizontal and vertical directions.
    · A series of display unit types that show operation status at a glance and adjustable operation keys that support double doors.
    · By changing the direction of the head in 4 directions, the operation key can be inserted in 4 directions.

    CAD :
    2D / 3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    - Standard Standard - - - - - Mutually Insulated Double Throw - - AC120/240V 10
    From: ₹ 20,153.73
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
CAD
From
Days to Ship
Detector Shape
Main Body Size
Environment
Plunger Shape Type
Number of Plunger Rows
Roller Lever Shape Type
Lever Shape Type
Rod Shape Type
Contact Type
Contact Point Type
Contact Material
Rated Operating Voltage(V)
Rated Conductance Current(A)

You can add up to 6 items per a category to the compare list.

Small Solenoid Lock / Safety Door Switch [D4SL-N]

    You can add up to 6 items per a category to the compare list.

    Solenoid Lock / Safety Door Switch / Slide Key Unit [D4JL/D4JL-SK40]

      You can add up to 6 items per a category to the compare list.

      Solenoid Lock / Safety Door Switch [D4BL]
        Brand

        OMRON

        OMRON

        OMRON

        Product Series

        Small Solenoid Lock / Safety Door Switch [D4SL-N]

        Solenoid Lock / Safety Door Switch / Slide Key Unit [D4JL/D4JL-SK40]

        Solenoid Lock / Safety Door Switch [D4BL]

        CAD
        • 2D / 3D
        • 2D / 3D
        From

        ₹ 8,845.50-

        ₹ 15,277.87-

        ₹ 20,153.73-

        Days to Ship 6 Day(s) or more 5 Day(s) or more 5 Day(s) or more
        Detector Shape---
        Main Body SizeSmall TypeStandardStandard
        EnvironmentStandardStandardStandard
        Plunger Shape Type---
        Number of Plunger Rows---
        Roller Lever Shape Type---
        Lever Shape Type---
        Rod Shape Type---
        Contact Type-Mutually Insulated Double ThrowMutually Insulated Double Throw
        Contact Point Type---
        Contact Material---
        Rated Operating Voltage(V)AC120/240VAC120/240VAC120/240V
        Rated Conductance Current(A)-1010

        Loading...

        1. 1

        Related Categories to Limit Switch

        FAQ Limit Switch

        Question: Can the Limit switch be used for doors?
        Answer: Yes, limit switches can be used for door safety functions. In fact, they are commonly used in industries to ensure the safe operation of doors, gates, and access points in automated systems. To use a limit switch for door safety, you would need a "safety limit switch."
        There are two main types of safety limit switches suitable for door safety:
        Mechanical Safety Limit Switches: These switches have a physical actuator that comes into contact with the door or gate, triggering the switch when the door reaches a certain position. They can be used to detect when the door is fully open or closed.
        Non-Contact Safety Limit Switches: Also called "safety interlock switches" or "coded magnet switches," these use non-contact technology to detect the presence or alignment of a magnet on the door. They are more tamper-resistant and are often used in critical safety applications.
        Question: What is the purpose of a Limit switch with a long lever?
        Answer: A limit switch with a long lever serves the purpose of detecting the presence, absence, or position of an object with a larger range of movement. The long lever acts as an extension, allowing the switch to respond to changes in position over a greater distance. This type of switch is commonly used in applications where the movement of the object being sensed is not directly aligned with the switch itself.
        For example, imagine a conveyor belt where products of varying sizes move along. A limit switch with a long lever could be positioned such that the lever comes into contact with the products. As each product passes by, it engages the lever, causing the switch to activate. The longer lever provides the necessary reach to detect objects that might be positioned farther away from the switch housing.
        In simpler terms, a limit switch with a long lever is like having an extended arm that can reach out and touch something that's not right next to it.
        Question: How do I connect or install a limit switch?
        Answer: Step by step to install the limit switch
        1. Choose Mounting Location: Determine where you want to install the limit switch. Make sure it's strategically placed to sense the desired movement or position.
        2. Prepare Mounting Surface: If needed, prepare the surface by drilling holes for mounting screws or bolts. Ensure the surface is clean and flat.
        3. Mounting: Attach the limit switch to the mounting surface using screws, bolts, or a bracket provided with the switch. Ensure the switch is securely fixed and aligned properly.
        4. Connect Wiring: Refer to the manufacturer's wiring diagram or schematic for guidance. Typically, limit switches have several terminals: common (COM), normally open (NO), and normally closed (NC). Connect wires from your control system to these terminals based on your application's requirements.
        5. Wire Connection: Strip the ends of the wires and attach them to the appropriate terminals. Use screw terminals, crimp connectors, or other suitable methods as specified by the switch's manual.
        6. Secure Wires: Make sure the wires are properly secured and won't be pinched or pulled when the machine or system operates.
        7. Adjust Actuator: If the limit switch uses an actuator (lever, roller, etc.), adjust its position so that it's activated when the desired movement or position is reached.
        8. Test the Installation: Carefully test the limit switch by manually triggering its actuator to see if it activates and deactivates correctly. Make any necessary adjustments if it's not functioning as expected.
        9. Final Check: Double-check all connections, screws, and adjustments to ensure everything is secure and properly aligned.
        10. Power On: Power up the system and observe the limit switch's behavior during regular operation. Confirm that it accurately detects the intended movement or position.
        X