(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:30 25/8/2024 to 0:00 (IST) 26/8/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

OMRON Limit Switch(Lever Shape Type:Hinge Lever)

OMRON offers products Limit Switch specified by Lever Shape Type Hinge Lever from Automation Components product category. There are a total of 3 items. Search and select detailed specifications of parts for your machine with free CAD downloads. OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • Others

3 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Compact Sealed Switch [ZC-□55]

    Compact Sealed Switch [ZC-□55]

    OMRON

    Compact seal switch with high durability (10 million times), and high accuracy

    [Features]
    · Compact and high accuracy seal switch: Compact and high accuracy seal switch with high durability of 10 million times or more, and high repeatability due to built-in micro switch.
    · Fitting pitch same as Z type.
    · Power required for operation (OF) is less as compared to the general limit switch.
    · Operation display convenient for maintenance and inspection is also available.
    · Approved by EN(TüV), UL, CCC.

    CAD :
    2D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Lever Shape (Push) / Roller lever type Small Type Standard - - - Hinge Lever - - - - AC240/250V 10
    From: ₹ 1,135.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Semi-Compact Sealed Switch [D4MC]

    Semi-Compact Sealed Switch [D4MC]

    OMRON

    Seal switch with improved strength, dust proof property and drip proof property

    [Features]
    · Seal switch with high durability of 10 million times or more and high repeatability due to built-in micro switch.
    · Operation position is same as Z type in case of panel fitting type.
    · Possible to use in applications requiring more strength, dust proof properties and drip proof properties than micro switch.
    · Resin hardened mold terminals are also available.
    · Approved by UL, CCC

    CAD :
    2D / 3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Lever Shape (Push) / Roller lever type Small Type Standard / Dust Resistant - - - Hinge Lever - Single Pole Double Throw - - 30 VDC or Less / AC240/250V 10
    From: ₹ 631.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Compact Enclosed Switch [SHL]

    Compact Enclosed Switch [SHL]

    OMRON

    [Features]
    · Compact general-purpose horizontal type
    · Series of micro load types is also made.
    · Built-in coil spring system switch boasting high durability in robust, precise die-cast case.
    · Compact and can be used in applications wherein single usage of micro switch is very unsafe

    CAD :
    2D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Lever Shape (Push) / Roller lever type Small Type Standard - - - Hinge Lever - Single Pole Double Throw - - 30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300V 15
    From: ₹ 998.00
    Days to Ship: Same day or more
    day to ship Same day or more
Brand
Product Series
CAD
From
Days to Ship
Detector Shape
Main Body Size
Environment
Plunger Shape Type
Number of Plunger Rows
Roller Lever Shape Type
Lever Shape Type
Rod Shape Type
Contact Type
Contact Point Type
Contact Material
Rated Operating Voltage(V)
Rated Conductance Current(A)

You can add up to 6 items per a category to the compare list.

Compact Sealed Switch [ZC-□55]

    You can add up to 6 items per a category to the compare list.

    Semi-Compact Sealed Switch [D4MC]

      You can add up to 6 items per a category to the compare list.

      Compact Enclosed Switch [SHL]
        Brand

        OMRON

        OMRON

        OMRON

        Product Series

        Compact Sealed Switch [ZC-□55]

        Semi-Compact Sealed Switch [D4MC]

        Compact Enclosed Switch [SHL]

        CAD
        • 2D
        • 2D / 3D
        • 2D
        From

        ₹ 1,135.00-

        ₹ 631.00-

        ₹ 998.00-

        Days to Ship Same day or more Same day or more Same day or more
        Detector ShapeLever Shape (Push) / Roller lever typeLever Shape (Push) / Roller lever typeLever Shape (Push) / Roller lever type
        Main Body SizeSmall TypeSmall TypeSmall Type
        EnvironmentStandardStandard / Dust ResistantStandard
        Plunger Shape Type---
        Number of Plunger Rows---
        Roller Lever Shape Type---
        Lever Shape TypeHinge LeverHinge LeverHinge Lever
        Rod Shape Type---
        Contact Type-Single Pole Double ThrowSingle Pole Double Throw
        Contact Point Type---
        Contact Material---
        Rated Operating Voltage(V)AC240/250V30 VDC or Less / AC240/250V30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300V
        Rated Conductance Current(A)101015

        Loading...

        1. 1

        Related Categories to Limit Switch

        FAQ Limit Switch

        Question: Can the Limit switch be used for doors?
        Answer: Yes, limit switches can be used for door safety functions. In fact, they are commonly used in industries to ensure the safe operation of doors, gates, and access points in automated systems. To use a limit switch for door safety, you would need a "safety limit switch."
        There are two main types of safety limit switches suitable for door safety:
        Mechanical Safety Limit Switches: These switches have a physical actuator that comes into contact with the door or gate, triggering the switch when the door reaches a certain position. They can be used to detect when the door is fully open or closed.
        Non-Contact Safety Limit Switches: Also called "safety interlock switches" or "coded magnet switches," these use non-contact technology to detect the presence or alignment of a magnet on the door. They are more tamper-resistant and are often used in critical safety applications.
        Question: What is the purpose of a Limit switch with a long lever?
        Answer: A limit switch with a long lever serves the purpose of detecting the presence, absence, or position of an object with a larger range of movement. The long lever acts as an extension, allowing the switch to respond to changes in position over a greater distance. This type of switch is commonly used in applications where the movement of the object being sensed is not directly aligned with the switch itself.
        For example, imagine a conveyor belt where products of varying sizes move along. A limit switch with a long lever could be positioned such that the lever comes into contact with the products. As each product passes by, it engages the lever, causing the switch to activate. The longer lever provides the necessary reach to detect objects that might be positioned farther away from the switch housing.
        In simpler terms, a limit switch with a long lever is like having an extended arm that can reach out and touch something that's not right next to it.
        Question: How do I connect or install a limit switch?
        Answer: Step by step to install the limit switch
        1. Choose Mounting Location: Determine where you want to install the limit switch. Make sure it's strategically placed to sense the desired movement or position.
        2. Prepare Mounting Surface: If needed, prepare the surface by drilling holes for mounting screws or bolts. Ensure the surface is clean and flat.
        3. Mounting: Attach the limit switch to the mounting surface using screws, bolts, or a bracket provided with the switch. Ensure the switch is securely fixed and aligned properly.
        4. Connect Wiring: Refer to the manufacturer's wiring diagram or schematic for guidance. Typically, limit switches have several terminals: common (COM), normally open (NO), and normally closed (NC). Connect wires from your control system to these terminals based on your application's requirements.
        5. Wire Connection: Strip the ends of the wires and attach them to the appropriate terminals. Use screw terminals, crimp connectors, or other suitable methods as specified by the switch's manual.
        6. Secure Wires: Make sure the wires are properly secured and won't be pinched or pulled when the machine or system operates.
        7. Adjust Actuator: If the limit switch uses an actuator (lever, roller, etc.), adjust its position so that it's activated when the desired movement or position is reached.
        8. Test the Installation: Carefully test the limit switch by manually triggering its actuator to see if it activates and deactivates correctly. Make any necessary adjustments if it's not functioning as expected.
        9. Final Check: Double-check all connections, screws, and adjustments to ensure everything is secure and properly aligned.
        10. Power On: Power up the system and observe the limit switch's behavior during regular operation. Confirm that it accurately detects the intended movement or position.
        X
        whatsapp-qr whatsapp-icon