(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:30 25/8/2024 to 0:00 (IST) 26/8/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

OMRON Limit Switch(Roller Lever Shape Type:Spring Rod Lever)

OMRON offers products Limit Switch specified by Roller Lever Shape Type Spring Rod Lever from Automation Components product category. There are a total of 2 items. Search and select detailed specifications of parts for your machine with free CAD downloads. OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • Others

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]

    Two-Circuit Limit Switch [WL-N/WL]

    OMRON

    The 2-circuit limit switch with variety of models that can be selected matching to the usage environment and application.

    [Features]
    · Circuit will break without fail by using 2-circuit double-break.
    · Structure suitable to IP67 due to O ring and/or cover seal.
    · Overseas approval corresponding to the machines for export approved by UL, CSA, TUV, EN/IEC, CCC.
    · Most suitable to machines for export.
    · Optimum high accuracy type in controlling the position is available in all types.
    · Movement till operation is less (about 5°) but repeatability is two times of standard type

    • Volume Discount
    CAD :
    2D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Roller Lever Type (Rotary) Standard Standard - - Spring Rod Lever - - 2-Circuit Double Break - - 30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300V 10
    From: ₹ 4,420.05
    Days to Ship: 5 Day(s)
    day to ship 5 Day(s)
  • You can add up to 6 items per a category to the compare list.

    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]

    Compact Heavy Equipment Limit Switch [D4A-□N]

    OMRON

    Standards with improved sealing properties, shock resistance properties and strength tolerance

    [Features]
    · A double seal on the head, a complete gasket cover, and other features ensure a better seal.
    · Wide standard operating temperature range (-40 to +100°C: standard type).
    · Models with fluoro-rubber available for greater resistance to chemicals.
    · Block mounting method also reduces downtime for maintenance.
    · 4-circuit double-break models available for complex operations

    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Rod Shape Small Type Standard / Cold Resistant - - Spring Rod Lever - Spring + Metal Rod 2-Circuit Double Break - - More than AC300V 10
    From: ₹ 4,359.80
    Days to Ship: 5 Day(s)
    day to ship 5 Day(s)
Brand
Product Series
CAD
From
Days to Ship
Detector Shape
Main Body Size
Environment
Plunger Shape Type
Number of Plunger Rows
Roller Lever Shape Type
Lever Shape Type
Rod Shape Type
Contact Type
Contact Point Type
Contact Material
Rated Operating Voltage(V)
Rated Conductance Current(A)

You can add up to 6 items per a category to the compare list.

Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]

    You can add up to 6 items per a category to the compare list.

    Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Compact Heavy Equipment Limit Switch [D4A-□N]
      Brand

      OMRON

      OMRON

      Product Series

      Two-Circuit Limit Switch [WL-N/WL]

      Compact Heavy Equipment Limit Switch [D4A-□N]

      CAD
      • 2D
      From

      ₹ 4,420.05-

      ₹ 4,359.80

      Days to Ship 5 Day(s) 5 Day(s)
      Detector ShapeRoller Lever Type (Rotary)Rod Shape
      Main Body SizeStandardSmall Type
      EnvironmentStandardStandard / Cold Resistant
      Plunger Shape Type--
      Number of Plunger Rows--
      Roller Lever Shape TypeSpring Rod LeverSpring Rod Lever
      Lever Shape Type--
      Rod Shape Type-Spring + Metal Rod
      Contact Type2-Circuit Double Break2-Circuit Double Break
      Contact Point Type--
      Contact Material--
      Rated Operating Voltage(V)30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300VMore than AC300V
      Rated Conductance Current(A)1010

      Loading...

      1. 1

      Related Categories to Limit Switch

      FAQ Limit Switch

      Question: Can the Limit switch be used for doors?
      Answer: Yes, limit switches can be used for door safety functions. In fact, they are commonly used in industries to ensure the safe operation of doors, gates, and access points in automated systems. To use a limit switch for door safety, you would need a "safety limit switch."
      There are two main types of safety limit switches suitable for door safety:
      Mechanical Safety Limit Switches: These switches have a physical actuator that comes into contact with the door or gate, triggering the switch when the door reaches a certain position. They can be used to detect when the door is fully open or closed.
      Non-Contact Safety Limit Switches: Also called "safety interlock switches" or "coded magnet switches," these use non-contact technology to detect the presence or alignment of a magnet on the door. They are more tamper-resistant and are often used in critical safety applications.
      Question: What is the purpose of a Limit switch with a long lever?
      Answer: A limit switch with a long lever serves the purpose of detecting the presence, absence, or position of an object with a larger range of movement. The long lever acts as an extension, allowing the switch to respond to changes in position over a greater distance. This type of switch is commonly used in applications where the movement of the object being sensed is not directly aligned with the switch itself.
      For example, imagine a conveyor belt where products of varying sizes move along. A limit switch with a long lever could be positioned such that the lever comes into contact with the products. As each product passes by, it engages the lever, causing the switch to activate. The longer lever provides the necessary reach to detect objects that might be positioned farther away from the switch housing.
      In simpler terms, a limit switch with a long lever is like having an extended arm that can reach out and touch something that's not right next to it.
      Question: How do I connect or install a limit switch?
      Answer: Step by step to install the limit switch
      1. Choose Mounting Location: Determine where you want to install the limit switch. Make sure it's strategically placed to sense the desired movement or position.
      2. Prepare Mounting Surface: If needed, prepare the surface by drilling holes for mounting screws or bolts. Ensure the surface is clean and flat.
      3. Mounting: Attach the limit switch to the mounting surface using screws, bolts, or a bracket provided with the switch. Ensure the switch is securely fixed and aligned properly.
      4. Connect Wiring: Refer to the manufacturer's wiring diagram or schematic for guidance. Typically, limit switches have several terminals: common (COM), normally open (NO), and normally closed (NC). Connect wires from your control system to these terminals based on your application's requirements.
      5. Wire Connection: Strip the ends of the wires and attach them to the appropriate terminals. Use screw terminals, crimp connectors, or other suitable methods as specified by the switch's manual.
      6. Secure Wires: Make sure the wires are properly secured and won't be pinched or pulled when the machine or system operates.
      7. Adjust Actuator: If the limit switch uses an actuator (lever, roller, etc.), adjust its position so that it's activated when the desired movement or position is reached.
      8. Test the Installation: Carefully test the limit switch by manually triggering its actuator to see if it activates and deactivates correctly. Make any necessary adjustments if it's not functioning as expected.
      9. Final Check: Double-check all connections, screws, and adjustments to ensure everything is secure and properly aligned.
      10. Power On: Power up the system and observe the limit switch's behavior during regular operation. Confirm that it accurately detects the intended movement or position.
      X
      whatsapp-qr whatsapp-icon