OMRON Limit Switch(Roller Lever Shape Type:Fork Lever Lock)

OMRON offers products Limit Switch specified by Roller Lever Shape Type Fork Lever Lock from Automation Components product category. There are a total of 2 items. Search and select detailed specifications of parts for your machine with free CAD downloads. OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • Others

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]

    Two-Circuit Limit Switch [WL-N/WL]

    OMRON

    The 2-circuit limit switch with variety of models that can be selected matching to the usage environment and application.

    [Features]
    · Circuit will break without fail by using 2-circuit double-break.
    · Structure suitable to IP67 due to O ring and/or cover seal.
    · Overseas approval corresponding to the machines for export approved by UL, CSA, TUV, EN/IEC, CCC.
    · Most suitable to machines for export.
    · Optimum high accuracy type in controlling the position is available in all types.
    · Movement till operation is less (about 5°) but repeatability is two times of standard type

    • Volume Discount
    CAD :
    2D / 3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Roller Lever Type (Rotary) Standard Standard - - Fork Lever Lock - - 2-Circuit Double Break - - 30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300V 10
    From: ₹ 3,746.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Small Safety Limit Switch [D4N]
    Small Safety Limit Switch [D4N]
    Small Safety Limit Switch [D4N]
    Small Safety Limit Switch [D4N]
    Small Safety Limit Switch [D4N]

    Small Safety Limit Switch [D4N]

    OMRON

    Safety limit switch standards. Enriched products provided globally

    CAD :
    3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Roller Lever Type (Rotary) Standard / Small Type Standard / Cold Resistant - - Fork Lever Lock Arm Lever - Mutually Insulated Double Throw / 2-Circuit Double Break Rivet - DC125V / DC250V / AC100/125V / AC240/250V 2.5
    From: ₹ 1,015.00
    Days to Ship: Same day or more
    day to ship Same day or more
Brand
Product Series
CAD
From
Days to Ship
Detector Shape
Main Body Size
Environment
Plunger Shape Type
Number of Plunger Rows
Roller Lever Shape Type
Lever Shape Type
Rod Shape Type
Contact Type
Contact Point Type
Contact Material
Rated Operating Voltage(V)
Rated Conductance Current(A)

You can add up to 6 items per a category to the compare list.

Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]

    You can add up to 6 items per a category to the compare list.

    Small Safety Limit Switch [D4N]
      Small Safety Limit Switch [D4N]
      Small Safety Limit Switch [D4N]
      Small Safety Limit Switch [D4N]
      Small Safety Limit Switch [D4N]
      Brand

      OMRON

      OMRON

      Product Series

      Two-Circuit Limit Switch [WL-N/WL]

      Small Safety Limit Switch [D4N]

      CAD
      • 2D / 3D
      • 3D
      From

      ₹ 3,746.00-

      ₹ 1,015.00-

      Days to Ship Same day or more Same day or more
      Detector ShapeRoller Lever Type (Rotary)Roller Lever Type (Rotary)
      Main Body SizeStandardStandard / Small Type
      EnvironmentStandardStandard / Cold Resistant
      Plunger Shape Type--
      Number of Plunger Rows--
      Roller Lever Shape TypeFork Lever LockFork Lever Lock
      Lever Shape Type-Arm Lever
      Rod Shape Type--
      Contact Type2-Circuit Double BreakMutually Insulated Double Throw / 2-Circuit Double Break
      Contact Point Type-Rivet
      Contact Material--
      Rated Operating Voltage(V)30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300VDC125V / DC250V / AC100/125V / AC240/250V
      Rated Conductance Current(A)102.5

      Loading...

      1. 1

      Related Categories to Limit Switch

      FAQ Limit Switch

      Question: Can the Limit switch be used for doors?
      Answer: Yes, limit switches can be used for door safety functions. In fact, they are commonly used in industries to ensure the safe operation of doors, gates, and access points in automated systems. To use a limit switch for door safety, you would need a "safety limit switch."
      There are two main types of safety limit switches suitable for door safety:
      Mechanical Safety Limit Switches: These switches have a physical actuator that comes into contact with the door or gate, triggering the switch when the door reaches a certain position. They can be used to detect when the door is fully open or closed.
      Non-Contact Safety Limit Switches: Also called "safety interlock switches" or "coded magnet switches," these use non-contact technology to detect the presence or alignment of a magnet on the door. They are more tamper-resistant and are often used in critical safety applications.
      Question: What is the purpose of a Limit switch with a long lever?
      Answer: A limit switch with a long lever serves the purpose of detecting the presence, absence, or position of an object with a larger range of movement. The long lever acts as an extension, allowing the switch to respond to changes in position over a greater distance. This type of switch is commonly used in applications where the movement of the object being sensed is not directly aligned with the switch itself.
      For example, imagine a conveyor belt where products of varying sizes move along. A limit switch with a long lever could be positioned such that the lever comes into contact with the products. As each product passes by, it engages the lever, causing the switch to activate. The longer lever provides the necessary reach to detect objects that might be positioned farther away from the switch housing.
      In simpler terms, a limit switch with a long lever is like having an extended arm that can reach out and touch something that's not right next to it.
      Question: How do I connect or install a limit switch?
      Answer: Step by step to install the limit switch
      1. Choose Mounting Location: Determine where you want to install the limit switch. Make sure it's strategically placed to sense the desired movement or position.
      2. Prepare Mounting Surface: If needed, prepare the surface by drilling holes for mounting screws or bolts. Ensure the surface is clean and flat.
      3. Mounting: Attach the limit switch to the mounting surface using screws, bolts, or a bracket provided with the switch. Ensure the switch is securely fixed and aligned properly.
      4. Connect Wiring: Refer to the manufacturer's wiring diagram or schematic for guidance. Typically, limit switches have several terminals: common (COM), normally open (NO), and normally closed (NC). Connect wires from your control system to these terminals based on your application's requirements.
      5. Wire Connection: Strip the ends of the wires and attach them to the appropriate terminals. Use screw terminals, crimp connectors, or other suitable methods as specified by the switch's manual.
      6. Secure Wires: Make sure the wires are properly secured and won't be pinched or pulled when the machine or system operates.
      7. Adjust Actuator: If the limit switch uses an actuator (lever, roller, etc.), adjust its position so that it's activated when the desired movement or position is reached.
      8. Test the Installation: Carefully test the limit switch by manually triggering its actuator to see if it activates and deactivates correctly. Make any necessary adjustments if it's not functioning as expected.
      9. Final Check: Double-check all connections, screws, and adjustments to ensure everything is secure and properly aligned.
      10. Power On: Power up the system and observe the limit switch's behavior during regular operation. Confirm that it accurately detects the intended movement or position.