(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

OMRON Limit Switch(Detector Shape:No Lever Type (Knurled Shaft))

OMRON offers products Limit Switch specified by Detector Shape No Lever Type (Knurled Shaft) from Automation Components product category. There are a total of 2 items. Search and select detailed specifications of parts for your machine with free CAD downloads. OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 1 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • Others

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]

    Compact Heavy Equipment Limit Switch [D4A-□N]

    OMRON

    Standards with improved sealing properties, shock resistance properties and strength tolerance

    [Features]
    · A double seal on the head, a complete gasket cover, and other features ensure a better seal.
    · Wide standard operating temperature range (-40 to +100°C: standard type).
    · Models with fluoro-rubber available for greater resistance to chemicals.
    · Block mounting method also reduces downtime for maintenance.
    · 4-circuit double-break models available for complex operations

    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    No Lever Type (Knurled Shaft) Small Type Standard / Cold Resistant - - - - - 2-Circuit Double Break / 4-Circuit Double Break - - AC100/125V / More than AC300V 5 ~ 10
    From: ₹ 3,998.27
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Small safety door hinge door switch

    Small safety door hinge door switch

    OMRON

    Compact safety hinge door switch made up of resin and supporting reduction in space of machine

    CAD :
    3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    No Lever Type (Knurled Shaft) Small Type Standard / Cold Resistant Side Surface Plunger - - - - Mutually Insulated Double Throw - - DC125V / DC250V 2.5
    From: ₹ 2,762.00
    Days to Ship: Same day or more
    day to ship Same day or more
Brand
Product Series
CAD
From
Days to Ship
Detector Shape
Main Body Size
Environment
Plunger Shape Type
Number of Plunger Rows
Roller Lever Shape Type
Lever Shape Type
Rod Shape Type
Contact Type
Contact Point Type
Contact Material
Rated Operating Voltage(V)
Rated Conductance Current(A)

You can add up to 6 items per a category to the compare list.

Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]
    Compact Heavy Equipment Limit Switch [D4A-□N]

    You can add up to 6 items per a category to the compare list.

    Small safety door hinge door switch
      Brand

      OMRON

      OMRON

      Product Series

      Compact Heavy Equipment Limit Switch [D4A-□N]

      Small safety door hinge door switch

      CAD
      • 3D
      From

      ₹ 3,998.27-

      ₹ 2,762.00-

      Days to Ship 5 Day(s) or more Same day or more
      Detector ShapeNo Lever Type (Knurled Shaft)No Lever Type (Knurled Shaft)
      Main Body SizeSmall TypeSmall Type
      EnvironmentStandard / Cold ResistantStandard / Cold Resistant
      Plunger Shape Type-Side Surface Plunger
      Number of Plunger Rows--
      Roller Lever Shape Type--
      Lever Shape Type--
      Rod Shape Type--
      Contact Type2-Circuit Double Break / 4-Circuit Double BreakMutually Insulated Double Throw
      Contact Point Type--
      Contact Material--
      Rated Operating Voltage(V)AC100/125V / More than AC300VDC125V / DC250V
      Rated Conductance Current(A)5 ~ 102.5

      Loading...

      1. 1

      Related Categories to Limit Switch

      FAQ Limit Switch

      Question: Can the Limit switch be used for doors?
      Answer: Yes, limit switches can be used for door safety functions. In fact, they are commonly used in industries to ensure the safe operation of doors, gates, and access points in automated systems. To use a limit switch for door safety, you would need a "safety limit switch."
      There are two main types of safety limit switches suitable for door safety:
      Mechanical Safety Limit Switches: These switches have a physical actuator that comes into contact with the door or gate, triggering the switch when the door reaches a certain position. They can be used to detect when the door is fully open or closed.
      Non-Contact Safety Limit Switches: Also called "safety interlock switches" or "coded magnet switches," these use non-contact technology to detect the presence or alignment of a magnet on the door. They are more tamper-resistant and are often used in critical safety applications.
      Question: What is the purpose of a Limit switch with a long lever?
      Answer: A limit switch with a long lever serves the purpose of detecting the presence, absence, or position of an object with a larger range of movement. The long lever acts as an extension, allowing the switch to respond to changes in position over a greater distance. This type of switch is commonly used in applications where the movement of the object being sensed is not directly aligned with the switch itself.
      For example, imagine a conveyor belt where products of varying sizes move along. A limit switch with a long lever could be positioned such that the lever comes into contact with the products. As each product passes by, it engages the lever, causing the switch to activate. The longer lever provides the necessary reach to detect objects that might be positioned farther away from the switch housing.
      In simpler terms, a limit switch with a long lever is like having an extended arm that can reach out and touch something that's not right next to it.
      Question: How do I connect or install a limit switch?
      Answer: Step by step to install the limit switch
      1. Choose Mounting Location: Determine where you want to install the limit switch. Make sure it's strategically placed to sense the desired movement or position.
      2. Prepare Mounting Surface: If needed, prepare the surface by drilling holes for mounting screws or bolts. Ensure the surface is clean and flat.
      3. Mounting: Attach the limit switch to the mounting surface using screws, bolts, or a bracket provided with the switch. Ensure the switch is securely fixed and aligned properly.
      4. Connect Wiring: Refer to the manufacturer's wiring diagram or schematic for guidance. Typically, limit switches have several terminals: common (COM), normally open (NO), and normally closed (NC). Connect wires from your control system to these terminals based on your application's requirements.
      5. Wire Connection: Strip the ends of the wires and attach them to the appropriate terminals. Use screw terminals, crimp connectors, or other suitable methods as specified by the switch's manual.
      6. Secure Wires: Make sure the wires are properly secured and won't be pinched or pulled when the machine or system operates.
      7. Adjust Actuator: If the limit switch uses an actuator (lever, roller, etc.), adjust its position so that it's activated when the desired movement or position is reached.
      8. Test the Installation: Carefully test the limit switch by manually triggering its actuator to see if it activates and deactivates correctly. Make any necessary adjustments if it's not functioning as expected.
      9. Final Check: Double-check all connections, screws, and adjustments to ensure everything is secure and properly aligned.
      10. Power On: Power up the system and observe the limit switch's behavior during regular operation. Confirm that it accurately detects the intended movement or position.
      X