(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

OMRON Limit Switch(Environment:Oil Resistant)

OMRON offers products Limit Switch specified by Environment Oil Resistant from Automation Components product category. There are a total of 6 items. Search and select detailed specifications of parts for your machine with free CAD downloads. OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 1 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • Others

6 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]

    Two-Circuit Limit Switch [WL-N/WL]

    OMRON

    The 2-circuit limit switch with variety of models that can be selected matching to the usage environment and application.

    [Features]
    · Circuit will break without fail by using 2-circuit double-break.
    · Structure suitable to IP67 due to O ring and/or cover seal.
    · Overseas approval corresponding to the machines for export approved by UL, CSA, TUV, EN/IEC, CCC.
    · Most suitable to machines for export.
    · Optimum high accuracy type in controlling the position is available in all types.
    · Movement till operation is less (about 5°) but repeatability is two times of standard type

    • Volume Discount
    CAD :
    2D / 3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Plunger Type / Roller Lever Type (Rotary) / Rod Shape Standard Oil Resistant Top Plunger / Roller Plungers - Standard / Variable Roller Lever - Spring + Metal Rod 2-Circuit Double Break - - AC100/125V / AC240/250V / More than AC300V 10
    From: ₹ 2,910.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Small Enclosed Switch [D4E-□N]

    Small Enclosed Switch [D4E-□N]

    OMRON

    Meets the needs such as light, thin, short and compact model, high durability and high seal with further improvement in performance of D4E.

    [Features]
    · Improved snap action property, high durability by changing lever ratio of spring of built-in switch board.
    · Excellent in dust resistance, oil resistance by using a cover for built-in switch.
    · Moreover, high durability of seal cap of plunger.
    · Connector system capable of reducing the maintenance time at the time of wiring (screw tightening terminals also available that one is accustomed to use)
    · Micro load type can be used in controlling electronic circuit by metal clad contacts.
    · Mold terminal type, mold terminal with operation display light type are also available in the spring tightening method.
    · EN(TÜV), U

    CAD :
    2D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Plunger Type / Roller Lever Type (Rotary) Small Type Oil Resistant Top Plunger / Roller Plungers - Standard One Way Roller Vertical / Hinge Roller Levers - Single Pole Double Throw - - 30 VDC or Less / AC100/125V 0.1 ~ 5
    From: ₹ 1,369.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Compact Enclosed Switch [SHL]

    Compact Enclosed Switch [SHL]

    OMRON

    [Features]
    · Compact general-purpose horizontal type
    · Series of micro load types is also made.
    · Built-in coil spring system switch boasting high durability in robust, precise die-cast case.
    · Compact and can be used in applications wherein single usage of micro switch is very unsafe

    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Plunger Type Small Type Oil Resistant Top Plunger / Roller Plungers - - - - Single Pole Double Throw - - 30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300V 0.5 ~ 15
    From: ₹ 1,726.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Oil Resistant Limit Switch [D4ER-□N]

    Oil Resistant Limit Switch [D4ER-□N]

    OMRON

    The oil resistance of D4E-N has been further improved

    [Features]
    · It uses HNBR/fluororubber with excellent oil resistance and prevents ingress of cutting fluid from moving parts
    · Equipped with a fluorine resin cable that's resistant to cutting fluid
    · A lineup of easily wired connector types (Smart Click Connector)
    · The microload type can be used for electronic circuit control using gold clad contacts
    · EN (TÜV) Standards Acquired
    · The mounting pitch is the same as D4E
    · Protection Degree IP67G (JIS C 0920 Annex 1)

    CAD :
    2D / 3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Plunger Type / Roller Lever Type (Rotary) Standard Oil Resistant Roller Plungers - Standard - - Single Pole Double Throw - Gold Alloy 30 VDC or Less 0.1 ~ 1
    From: ₹ 5,207.96
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]
    Multi-Pull Limit Switch [VB]

    Multi-Pull Limit Switch [VB]

    OMRON

    VB type appeared with new form. Improvement in strength and sealing property of head with integrated head box. Drastic improvement in mechanical durability.

    [Features]
    · Possible to use in various types of machine tools and sequence controlling such as transfer/machine.
    · Possible to remove oil/water though entered into the plunger as oil filter is provided.
    · Approved by EN/IEC (only with earth terminal), and approved by CCC.
    · The product with earth terminal supports CE marking.

    CAD :
    3D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Plunger Type Standard Oil Resistant Multiple 2 / 3 / 4 / 6 - - - Single Pole Double Throw - - AC100/125V / AC240/250V 10
    From: ₹ 8,765.11
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Small Enclosed Switch VE

    Small Enclosed Switch VE

    OMRON

    [Features]
    · Compact and light weight seal switch.
    · Excellent dust proof and mechanically strong V type compact basic switch by sealing it in die-cast case.
    · In case of cams/arms types and cams/roller arms type, the position of arm can be set to 360° random position.

    CAD :
    2D
    Detector Shape Main Body Size Environment Plunger Shape Type Number of Plunger Rows Roller Lever Shape Type Lever Shape Type Rod Shape Type Contact Type Contact Point Type Contact Material Rated Operating Voltage(V) Rated Conductance Current(A)
    Plunger Type / Others Small Type Oil Resistant Top Plunger - Standard Arm Lever - Single Pole Double Throw - - AC240/250V 10
    From: ₹ 2,489.66
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
CAD
From
Days to Ship
Detector Shape
Main Body Size
Environment
Plunger Shape Type
Number of Plunger Rows
Roller Lever Shape Type
Lever Shape Type
Rod Shape Type
Contact Type
Contact Point Type
Contact Material
Rated Operating Voltage(V)
Rated Conductance Current(A)

You can add up to 6 items per a category to the compare list.

Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]
    Two-Circuit Limit Switch [WL-N/WL]

    You can add up to 6 items per a category to the compare list.

    Small Enclosed Switch [D4E-□N]

      You can add up to 6 items per a category to the compare list.

      Compact Enclosed Switch [SHL]

        You can add up to 6 items per a category to the compare list.

        Oil Resistant Limit Switch [D4ER-□N]

          You can add up to 6 items per a category to the compare list.

          Multi-Pull Limit Switch [VB]
            Multi-Pull Limit Switch [VB]
            Multi-Pull Limit Switch [VB]
            Multi-Pull Limit Switch [VB]
            Multi-Pull Limit Switch [VB]
            Multi-Pull Limit Switch [VB]
            Multi-Pull Limit Switch [VB]
            Multi-Pull Limit Switch [VB]

            You can add up to 6 items per a category to the compare list.

            Small Enclosed Switch VE
              Brand

              OMRON

              OMRON

              OMRON

              OMRON

              OMRON

              OMRON

              Product Series

              Two-Circuit Limit Switch [WL-N/WL]

              Small Enclosed Switch [D4E-□N]

              Compact Enclosed Switch [SHL]

              Oil Resistant Limit Switch [D4ER-□N]

              Multi-Pull Limit Switch [VB]

              Small Enclosed Switch VE

              CAD
              • 2D / 3D
              • 2D
              • 2D / 3D
              • 3D
              • 2D
              From

              ₹ 2,910.00-

              ₹ 1,369.00-

              ₹ 1,726.00-

              ₹ 5,207.96-

              ₹ 8,765.11-

              ₹ 2,489.66-

              Days to Ship Same day or more Same day or more Same day or more 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more
              Detector ShapePlunger Type / Roller Lever Type (Rotary) / Rod ShapePlunger Type / Roller Lever Type (Rotary)Plunger TypePlunger Type / Roller Lever Type (Rotary)Plunger TypePlunger Type / Others
              Main Body SizeStandardSmall TypeSmall TypeStandardStandardSmall Type
              EnvironmentOil ResistantOil ResistantOil ResistantOil ResistantOil ResistantOil Resistant
              Plunger Shape TypeTop Plunger / Roller PlungersTop Plunger / Roller PlungersTop Plunger / Roller PlungersRoller PlungersMultipleTop Plunger
              Number of Plunger Rows----2 / 3 / 4 / 6-
              Roller Lever Shape TypeStandard / Variable Roller LeverStandard-Standard-Standard
              Lever Shape Type-One Way Roller Vertical / Hinge Roller Levers---Arm Lever
              Rod Shape TypeSpring + Metal Rod-----
              Contact Type2-Circuit Double BreakSingle Pole Double ThrowSingle Pole Double ThrowSingle Pole Double ThrowSingle Pole Double ThrowSingle Pole Double Throw
              Contact Point Type------
              Contact Material---Gold Alloy--
              Rated Operating Voltage(V)AC100/125V / AC240/250V / More than AC300V30 VDC or Less / AC100/125V30 VDC or Less / DC125V / DC250V / AC100/125V / AC240/250V / More than AC300V30 VDC or LessAC100/125V / AC240/250VAC240/250V
              Rated Conductance Current(A)100.1 ~ 50.5 ~ 150.1 ~ 11010

              Loading...

              1. 1

              Related Categories to Limit Switch

              FAQ Limit Switch

              Question: Can the Limit switch be used for doors?
              Answer: Yes, limit switches can be used for door safety functions. In fact, they are commonly used in industries to ensure the safe operation of doors, gates, and access points in automated systems. To use a limit switch for door safety, you would need a "safety limit switch."
              There are two main types of safety limit switches suitable for door safety:
              Mechanical Safety Limit Switches: These switches have a physical actuator that comes into contact with the door or gate, triggering the switch when the door reaches a certain position. They can be used to detect when the door is fully open or closed.
              Non-Contact Safety Limit Switches: Also called "safety interlock switches" or "coded magnet switches," these use non-contact technology to detect the presence or alignment of a magnet on the door. They are more tamper-resistant and are often used in critical safety applications.
              Question: What is the purpose of a Limit switch with a long lever?
              Answer: A limit switch with a long lever serves the purpose of detecting the presence, absence, or position of an object with a larger range of movement. The long lever acts as an extension, allowing the switch to respond to changes in position over a greater distance. This type of switch is commonly used in applications where the movement of the object being sensed is not directly aligned with the switch itself.
              For example, imagine a conveyor belt where products of varying sizes move along. A limit switch with a long lever could be positioned such that the lever comes into contact with the products. As each product passes by, it engages the lever, causing the switch to activate. The longer lever provides the necessary reach to detect objects that might be positioned farther away from the switch housing.
              In simpler terms, a limit switch with a long lever is like having an extended arm that can reach out and touch something that's not right next to it.
              Question: How do I connect or install a limit switch?
              Answer: Step by step to install the limit switch
              1. Choose Mounting Location: Determine where you want to install the limit switch. Make sure it's strategically placed to sense the desired movement or position.
              2. Prepare Mounting Surface: If needed, prepare the surface by drilling holes for mounting screws or bolts. Ensure the surface is clean and flat.
              3. Mounting: Attach the limit switch to the mounting surface using screws, bolts, or a bracket provided with the switch. Ensure the switch is securely fixed and aligned properly.
              4. Connect Wiring: Refer to the manufacturer's wiring diagram or schematic for guidance. Typically, limit switches have several terminals: common (COM), normally open (NO), and normally closed (NC). Connect wires from your control system to these terminals based on your application's requirements.
              5. Wire Connection: Strip the ends of the wires and attach them to the appropriate terminals. Use screw terminals, crimp connectors, or other suitable methods as specified by the switch's manual.
              6. Secure Wires: Make sure the wires are properly secured and won't be pinched or pulled when the machine or system operates.
              7. Adjust Actuator: If the limit switch uses an actuator (lever, roller, etc.), adjust its position so that it's activated when the desired movement or position is reached.
              8. Test the Installation: Carefully test the limit switch by manually triggering its actuator to see if it activates and deactivates correctly. Make any necessary adjustments if it's not functioning as expected.
              9. Final Check: Double-check all connections, screws, and adjustments to ensure everything is secure and properly aligned.
              10. Power On: Power up the system and observe the limit switch's behavior during regular operation. Confirm that it accurately detects the intended movement or position.
              X