(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:30 24/11/2024 to 4:30 (IST) 25/11/2024. We apologize for the inconvenience.
  • Please note that the MISUMI Pune office and warehouse will be closed on November 20th due to the state election.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

OMRON PLC (Wire-Saving Dedicated Units)(Mounting Method:Screw mount)

OMRON offers products PLC (Wire-Saving Dedicated Units) specified by Mounting Method Screw mount from Electrical & Controls product category. There are a total of 2 items. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies OMRON products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    DRT2 board terminal

    DRT2 board terminal

    OMRON

    Smart slave, board-type PLC (dedicated wiring-saving unit).
    [Features]
    ·It can easily support various I/O interfaces and realizes reduced wiring.
    ·The DRT2-□D32BV (-1) type can be easily attached to a printed circuit board created by the user with screws.
    ·I/O terminal: MIL connector type.
    ·Internal circuit power supply rated voltage: Supplied from communication connector.
    ·Rated voltage of I/O power supply: 24 V DC.

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Slave station DeviceNet Input/Output / Communication Function Terminal Block Screw mount CE / UL / CUL / CSA
    From: ₹ 35,357.00
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    DRT2 environmental terminal

    DRT2 environmental terminal

    OMRON

    A lineup of remote I/O terminals with high environmental resistance (IP67) and mixed input, output, and input/output types with an emphasis on economy.
    [Features]
    ・ Abnormal diagnosis such as sensor power supply short circuit detection is also possible
    ・ Equipped with a common function for smart slaves, it strongly supports monitoring of the operating status of the device and effective maintenance
    ・ Achieves high environmental resistance dust-proof and drip-proof (IP67)
    ・ For input/output. PNP compatible (input (-) common / output (+) common). 8 points for input / 8 points for output
    ・ I/O connection form: Sensor I/O connector
    ・ Internal circuit power supply rated voltage: Supplied from communication connector
    ・ Rated voltage of I/O power supply: DC24V

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Slave station DeviceNet Input/Output / Communication Function Connector Screw mount CE / UL / CUL / CSA
    From: ₹ 45,703.00
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
Brand
Product Series
From
Days to Ship
Type
Control Type Network Varieties
Additional Function
Connection Terminal
Mounting Method
Representative Standard

You can add up to 6 items per a category to the compare list.

DRT2 board terminal

    You can add up to 6 items per a category to the compare list.

    DRT2 environmental terminal
      Brand

      OMRON

      OMRON

      Product Series

      DRT2 board terminal

      DRT2 environmental terminal

      From

      ₹ 35,357.00-

      ₹ 45,703.00

      Days to Ship 6 Day(s) or more 6 Day(s) or more
      TypeSlave stationSlave station
      Control Type Network VarietiesDeviceNetDeviceNet
      Additional FunctionInput/Output / Communication FunctionInput/Output / Communication Function
      Connection TerminalTerminal BlockConnector
      Mounting MethodScrew mountScrew mount
      Representative StandardCE / UL / CUL / CSACE / UL / CUL / CSA

      Loading...

      1. 1

      Related Categories to PLC (Wire-Saving Dedicated Units)

      FAQ PLC (Wire-Saving Dedicated Units)

      Question: What are the unique features of PLC Wire-Saving Dedicated Units and how do they benefit industrial automation?
      Answer: PLC Wire-Saving Dedicated Units offer streamlined connectivity by reducing the number of wires needed for communication. These units often employ advanced communication protocols and compact designs, minimizing wiring complexity. This not only simplifies installation but also enhances the overall reliability of the industrial automation system.
      Question: How do Digital and Analog I/O Units integrate with PLC Wire-Saving systems?
      Answer: Digital and Analog I/O Units seamlessly integrate with PLC Wire-Saving systems by connecting through a simplified wiring scheme. Digital I/O handles discrete signals, while Analog I/O manages continuous signals. Both types contribute to efficient data exchange between the PLC and various devices in the automation setup, supporting precise control and monitoring.
      Question: What are the mounting and installation methods available for PLC Wire-Saving Dedicated Units?
      Answer: PLC Wire-Saving Dedicated Units offer versatile mounting options, including DIN rail mounting for easy integration into control panels. Some units also support direct mounting on machines or equipment, providing flexibility in installation. This adaptability simplifies the deployment of these units in diverse industrial settings.
      Question: What are the key considerations when selecting Analog I/O units for PLC systems?
      Answer: When selecting Analog I/O units for PLC systems, key considerations include the required resolution, speed, and accuracy of the analog signals. Engineers should also evaluate compatibility with the PLC model, signal types supported (e.g., voltage or current), and the specific needs of the application. Additionally, considering factors like environmental conditions and electromagnetic interference ensures optimal performance in industrial settings.