MISUMI Thermocouples(Thermocouples type:J type)

MISUMI offers products Thermocouples specified by Thermocouples type J type from Plastic Mold Components product category. There are a total of 2 items. Plastic Molding Parts and accessories. MISUMI products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 6 Day(s) or Less

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Sheathed Thermocouples

    Sheathed Thermocouples

    MISUMI

    [Specifications]
    ・Type: K type・J type
    ・Tip shape: Non-ground type
    ・Tolerance class: Class 2

    • Volume Discount
    CAD :
    2D / 3D
    Thermocouples type How to mount Max. temperature(℃) Brand
    J type Jig 450 ~ 750 -
    From: ₹ 3,068.00
    Days to Ship: Same day or more
    day to ship Same day or more
  • You can add up to 6 items per a category to the compare list.

    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-
    Sheathed Thermocouples -Spring Attachment Type-

    Sheathed Thermocouples -Spring Attachment Type-

    MISUMI

    [Features] - Easy installation/removal.・Type: K type, J type ・Tolerance class: Class 2

    • Volume Discount
    CAD :
    2D / 3D
    Thermocouples type How to mount Max. temperature(℃) Brand
    J type Spring attachment 300 -
    From: ₹ 5,227.00
    Days to Ship: Same day
    day to ship Same day
Brand
Product Series
CAD
From
Days to Ship
Thermocouples type
How to mount
Max. temperature(℃)
Brand

You can add up to 6 items per a category to the compare list.

Sheathed Thermocouples

    You can add up to 6 items per a category to the compare list.

    Sheathed Thermocouples -Spring Attachment Type-
      Sheathed Thermocouples -Spring Attachment Type-
      Sheathed Thermocouples -Spring Attachment Type-
      Sheathed Thermocouples -Spring Attachment Type-
      Sheathed Thermocouples -Spring Attachment Type-
      Brand

      MISUMI

      MISUMI

      Product Series

      Sheathed Thermocouples

      Sheathed Thermocouples -Spring Attachment Type-

      CAD
      • 2D / 3D
      • 2D / 3D
      From

      ₹ 3,068.00-

      ₹ 5,227.00

      Days to Ship Same day or more Same day
      Thermocouples typeJ typeJ type
      How to mountJigSpring attachment
      Max. temperature(℃)450 ~ 750300
      Brand--

      Loading...

      1. 1

      Related Categories to Thermocouples

      FAQ Thermocouples

      Question: What are the types of thermocouples and their temperature range?
      Answer: Common thermocouple types include:
      Type K: General-purpose, wide range, temperature range -200°C to 1350°C
      Type J: Suitable for lower temperatures, temperature range -40°C to 750°C
      Type T: Best for low-temperature measurements, temperature range -200°C to 350°C
      Type E: High accuracy and sensitivity, temperature range -200°C to 900°C
      Type N: High temperature, better oxidation resistance, temperature range -200°C to 1300°C
      Question: How do I select the right thermocouple for my application?
      Answer: Consider the following factors to select the right thermocouple:
      Temperature range: Ensure the thermocouple can withstand the temperature of your environment.
      Material compatibility: Some thermocouple materials work better in certain environments (e.g., corrosive or oxidizing atmospheres).
      Accuracy and sensitivity needs: Different types have varying levels of sensitivity and accuracy.
      Environment: Ensure your thermocouple can withstand vibrations, pressure, or moisture if needed.
      Question: What causes a thermocouple to fail?
      Answer: Common causes of thermocouple failure include:
      • Mechanical damage
      • Exposure to extreme temperatures beyond its rating
      • Oxidation or corrosion
      • Electrical short circuits
      • Metal fatigue
      Question: What are the different types of thermocouple signal conditioners?
      Answer: Analog signal conditioners: Convert the thermocouple voltage into an analog output (e.g., 4-20 mA current loop).
      Digital signal conditioners: Convert the thermocouple voltage into a digital signal (e.g., RS-232, USB).
      Integrated signal conditioners: Combine analog and digital functions in a single unit.
      X
      whatsapp-qr whatsapp-icon