NP84 Series Contact Probes Min Pitch3.0mm, Stroke 6.3mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1.25 ~ 2.54 | 3 | One Side Probe | 3 | 8.1~12 | - | 2 | 20.1~25 | - | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | 50 | - | 5~6.5 | 30.1~50 / 100.1~150 / 150.1~200 | Copper Alloy | 0~10 ~ 50.1~100 |
From: ₹ 58.35 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
NP58 Series Contact Probes Min Pitch1.00mm, Stroke 2.0mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.38 ~ 0.8 | 1 | One Side Probe | 1.9 | 0.1~3 ~ 3.1~5 | - | 0.58 | 10.1~15 | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | 70 | - | 1~2.6 | 30.1~50 | Copper Alloy | 20.1~30 |
From: ₹ 48.72 |
---|
Days to Ship: 12 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-88 Series
MISUMI
"Full Stroke: 2.5mm | Number of Mounting Points Crowned Type: 9, 12 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.69 ~ 1 | 1.5 | One Side Probe | 3 | 3.1~5 | - | 0.88 | 10.1~15 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 60 ~ 80 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | 1~2.6 | 30.1~50 / 50.1~100 | Copper Alloy | 0~10 ~ 20.1~30 |
From: ₹ 214.28 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-90 Series
MISUMI
"Full Stroke: 6.4mm | Number of Mounting Points (Crowned): 4, 9, Waffle Type: 4, 9, 12 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1.5 ~ 4 | 3.5 ~ 4.5 | One Side Probe | 1.5 | 8.1~12 | - | 2.33 | 20.1~25 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy | 80 | Needle / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | 5~6.5 | 30.1~50 / 100.1~150 / 200.1~300 | Copper Alloy | 0~10 ~ 100.1~200 |
From: ₹ 603.90 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-30 Series
MISUMI
"Full Stroke: 2.5mm | Number of Mounting Points Crowned Type: 4 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.48 ~ 1 | 1.27 | One Side Probe | 1 | 3.1~5 | - | 0.68 | 10.1~15 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy / Carbon Steel | 100 | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | 1~2.6 | 30.1~50 / 50.1~100 | Copper Alloy | 0~10 ~ 30.1~50 |
From: ₹ 253.24 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-84 Series
MISUMI
"Full Stroke: 6.3mm | Number of Mounting Points Crowned Type: 4, Waffle Type: 9 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1.3 ~ 2.54 | 3 | One Side Probe | 1.5 | 8.1~12 | - | 2 | 20.1~25 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy | 80 | Needle / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | 5~6.5 | 30.1~50 / 100.1~150 / 150.1~200 | Copper Alloy | 0~10 ~ 50.1~100 |
From: ₹ 390.00 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-45S Series
MISUMI
"Full Stroke: 3.0mm | Number of Mounting Points Crowned Type: 4, 9, Waffle Type: 9 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.68 ~ 1.5 | 1.7 | One Side Probe | 1.5 ~ 3 | 3.1~5 | - | 1 | 10.1~15 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy / Carbon Steel | 60 ~ 80 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Waffle | 3~4.5 | 30.1~50 / 50.1~100 | Copper Alloy | 20.1~30 |
From: ₹ 147.00 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-89 Series
MISUMI
"Full Stroke: 6.4mm | Number of Mounting Points Crowned Type: 12, Waffle Type: 12 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1.96 ~ 3.95 | 4.5 | One Side Probe | 1.5 | 8.1~12 | - | 3.18 | 25.1~30 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy | 80 | Needle / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | 5~6.5 | 50.1~100 / 200.1~300 / 300.1~ | Copper Alloy | 20.1~30 ~ 100.1~200 |
From: ₹ 662.34 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
NP76 Series Contact Probes Min Pitch 1.27mm, Stroke 6.0mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.5 ~ 1 | 1.27 | One Side Probe | 3 | 5.1~8 | - | 0.76 | 25.1~30 | - | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | 60 | - | 5~6.5 | 100.1~150 | Copper Alloy | 50.1~100 |
From: ₹ 35.39 |
---|
Days to Ship: 12 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-604 Series
MISUMI
"Full Stroke: 4mm | Number of Mounting Points Waffle Type: 4 | Cup Angle: 60°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 ~ 1.9 | 2.54 | One Side Probe | 1.5 ~ 3 | 5.1~8 | - | 1.37 | 15.1~20 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy | 80 | Needle / Sphere Shape (SR) / Cup / Waffle | 3~4.5 | 50.1~100 / 100.1~150 / 150.1~200 | Copper Alloy | 0~10 ~ 30.1~50 |
From: ₹ 88.00 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPM156 Series/NRM156 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 6.35mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.5 | 3.96 | One Side Probe | - | - | - | - | - | Spring Externally Mounted / Spring Built-in | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Cup / Straight Crown / Waffle | - | - | Copper Alloy | - |
From: ₹ 162.08 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
NP88 Series Contact Probes Min Pitch 1.5mm, Stroke 2.5mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.67 ~ 1 | 1.5 | One Side Probe | 3 | 3.1~5 | - | 0.88 | 10.1~15 | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | 60 | - | 1~2.6 | 30.1~50 / 50.1~100 | Copper Alloy | 0~10 ~ 20.1~30 |
From: ₹ 32.28 |
---|
Days to Ship: 12 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-60 Series
MISUMI
"Full Stroke 6.4mm | Number of Mounting Points Crowned Type: 4, 9, 12, 21 Waffle Type: 4, 9, 12 | Cup Angle: 90°, Needle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 ~ 2.4 | 2.54 | One Side Probe | 1.5 | 8.1~12 ~ 12.1~15 | - | 1.37 | 20.1~25 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy / Carbon Steel | 80 | Needle / Three-Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Waffle | 5~6.5 | 30.1~50 / 50.1~100 / 100.1~150 / 150.1~200 | Copper Alloy | 10.1~20 ~ 20.1~30 |
From: ₹ 72.00 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-45 Series
MISUMI
"Full Stroke: 5.0mm | Number of Mounting Points Crowned Type: 4, 9, Waffle Type: 4, 9 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.68 ~ 1.3 | 1.7 | One Side Probe | 1.5 ~ 3 | 5.1~8 | - | 1.02 | 20.1~25 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy / Carbon Steel | 60 ~ 80 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown / Waffle | 5~6.5 | 30.1~50 / 50.1~100 / 100.1~150 | Copper Alloy | 0~10 ~ 30.1~50 |
From: ₹ 146.10 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-38 Series
MISUMI
"Full Stroke: 2.0mm | Number of Mounting Points Crowned Type: 4, 9 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.29 ~ 0.4 | 0.8 | One Side Probe | 1 | 0.1~3 ~ 3.1~5 | - | 0.38 | 5~10 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 180 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | 1~2.6 | 30.1~50 | Copper Alloy | 10.1~20 |
From: ₹ 487.00 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-72 Series
MISUMI
"Full Stroke: 2.5mm | Number of Mounting Points Crowned Type: 7, 9, Waffle Type: 7, 12 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.54 ~ 0.9 | 1.27 | One Side Probe | 1 | 3.1~5 | - | 0.72 | 10.1~15 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 80 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Waffle | 1~2.6 | 30.1~50 / 50.1~100 | Copper Alloy | 10.1~20 ~ 20.1~30 |
From: ₹ 303.89 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-120 Series
MISUMI
"Full Stroke: 6.5mm | Number of Mounting Points Crowned Type: 4, 9 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.93 ~ 1.5 | 2 | One Side Probe | 1.5 | 8.1~12 | - | 1.2 | 20.1~25 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 80 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | 5~6.5 | 30.1~50 / 50.1~100 | Copper Alloy | 10.1~20 ~ 20.1~30 |
From: ₹ 189.93 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact probe/receptacle 68S3 series
MISUMI
"Full Stroke 4.3mm | Number of Mounting Points Waffle Type: 9 | Cup Angle: 90°, Needle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1.27 | One Side Probe | 2 | 5.1~8 | - | 0.68 | 15.1~20 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 80 | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Flat / Waffle | 3~4.5 | 30.1~50 / 50.1~100 | Copper Alloy | 20.1~30 |
From: ₹ 278.56 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probe / Receptacle (With Lead), 058 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 1.9mm
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 | One Side Probe | - | - | - | - | - | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Triangular Pyramid / Sphere Shape (SR) / Tapered Crown | - | - | Copper Alloy | - |
From: ₹ 84.42 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
NP120 Series Contact Probes Min Pitch 2.0mm, Stroke 6.5mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.93 ~ 1.5 | 2 | One Side Probe | 2.5 | 8.1~12 | - | 1.2 | 20.1~25 | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | 60 | - | 5~6.5 | 30.1~50 / 50.1~100 | Copper Alloy | 10.1~20 ~ 20.1~30 |
From: ₹ 57.16 |
---|
Days to Ship: 12 Day(s) or more |
You can add up to 6 items per a category to the compare list.
NP45 Series Contact Probes Min Pitch 1.7mm, Stroke 5.0mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.75 ~ 1.3 | 1.7 | One Side Probe | 3 | 3.1~5 ~ 5.1~8 | - | 1 ~ 1.02 | 10.1~15 / 20.1~25 | - | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | 60 | - | 3~4.5 / 5~6.5 | 30.1~50 / 50.1~100 / 100.1~150 | Copper Alloy | 0~10 ~ 30.1~50 |
From: ₹ 52.61 |
---|
Days to Ship: 12 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-58 Series
MISUMI
"Full Stroke: 2.0mm | Number of Mounting Points Crowned Type: 4 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.42 ~ 0.8 | 1 | One Side Probe | 1 | 0.1~3 ~ 3.1~5 | - | 0.58 | 10.1~15 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 100 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | 1~2.6 | 30.1~50 | Copper Alloy | 20.1~30 |
From: ₹ 417.85 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-76 Series
MISUMI
"Full Stroke: 6.0mm | Number of Mounting Points Crowned Type: 4, 9, Waffle Type: 4 | Cup Angle: 90°, Needle Angle: 50°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.48 ~ 1 | 1.27 | One Side Probe | 1.3 | 5.1~8 | - | 0.76 | 25.1~30 | - | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | 80 | Needle / Cup / Straight Crown / Tapered Crown / Waffle | 5~6.5 | 100.1~150 | Copper Alloy | 50.1~100 |
From: ₹ 233.76 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probe/Receptacle 68 Series
MISUMI
"Full Stroke 4.3mm | Number of Mounting Points Crowned Type: 7, 21 Waffle Type: 7, 9, 21 | Cup Angle: 90°, Needle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.49 ~ 1.2 | 1.4 | One Side Probe | 2.5 | 5.1~8 | - | 0.68 | 15.1~20 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 60 ~ 80 | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | 3~4.5 | 30.1~50 / 50.1~100 | Copper Alloy | 20.1~30 |
From: ₹ 214.28 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probe / Receptacle (With Lead), 030 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 1mm
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 0.55 | One Side Probe | - | - | - | - | - | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Sphere Shape (SR) / Straight Crown | - | - | Copper Alloy | - |
From: ₹ 361.30 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
NP20 Series Contact Probes Min Pitch 0.9mm, Stroke 2.0mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.35 ~ 0.5 | 0.9 | One Side Probe | 1.5 | 0.1~3 ~ 5.1~8 | - | 0.48 | 10.1~15 | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | 80 | - | 1~2.6 / 3~4.5 | 30.1~50 | Copper Alloy | 10.1~20 |
From: ₹ 63.83 |
---|
Days to Ship: 12 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPT0 Series/NRT0W Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 2.6mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.5 | 1.27 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Straight Crown / Tapered Crown | - | - | Copper Alloy | - |
From: ₹ 57.15 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPQ75 Series/NRQ75 Series/C-Value【50 Pieces Per Package】
MISUMI
Estimated replacement time is 200,000 times. The 75 series probe is specialized for medium precision applications. We help our large customers reduce costs.
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.5 | 1.91 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | - | Needle / Triangular Pyramid / Cup / Straight Crown / Tapered Crown | - | - | Copper Alloy | - |
From: ₹ 121.56 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
NP604 Series Contact Probes Min Pitch2.54mm, Stroke 4.0mm【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.99 ~ 1.9 | 2.54 | One Side Probe | 3 | 5.1~8 | - | 1.37 | 15.1~20 | - | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | 50 | - | 3~4.5 | 100.1~150 / 150.1~200 | Copper Alloy | 0~10 ~ 30.1~50 |
From: ₹ 53.96 |
---|
Days to Ship: 12 Day(s) |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-26 Series
MISUMI
"Full Stroke: 2.0mm | Number of Mounting Points Crowned Type: 4 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.15 ~ 0.3 | 0.5 | One Side Probe | 0.5 | 0.1~3 ~ 3.1~5 | - | 0.26 | 5~10 | Spring Built-in | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | 200 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | 1~2.6 | 0~30 | Copper Alloy | 0~10 |
From: ₹ 1,012.96 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-31 Series
MISUMI
"Full Stroke: 2.0mm | Number of Mounting Points Crowned Type: 4 | Cup Angle: 90°, Needle Angle: 90°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.21 ~ 0.34 | 0.6 | One Side Probe | 1 | 0.1~3 ~ 3.1~5 | - | 0.31 | 5~10 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Carbon Steel | 180 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | 1~2.6 | 0~30 | Copper Alloy | 0~10 |
From: ₹ 759.72 |
---|
Days to Ship: Same day or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-20 Series
MISUMI
"Full Stroke: 3.0mm | Number of Mounting Points Crowned Type: 4 | Cup Angle: 90°, Needle Angle: 60°"
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.37 ~ 0.5 | 0.9 | One Side Probe | 1 | 0.1~3 ~ 3.1~5 | - | 0.48 | 10.1~15 | - | Nickel Plating Base, Rhodium Plating | - | Standard | Copper Alloy / Carbon Steel | 100 | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | 1~2.6 / 3~4.5 | 30.1~50 | Copper Alloy | 10.1~20 |
From: ₹ 607.78 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPQ50 Series/NRQ50 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 6.35mm | Number of Mounting Points Crowned Type: 4, 9
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1.27 | One Side Probe | - | - | - | - | - | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Cup / Tapered Crown / Waffle | - | - | Copper Alloy | - |
From: ₹ 158.71 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probe / Receptacle (Low Spring Pressure), 100 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 6.35mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.5 | 2.54 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Cup / Straight Crown / Waffle | - | - | Copper Alloy | - |
From: ₹ 97.93 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPM125 Series/NRM125 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package. | Full Stroke 635mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.03 | 3.18 | One Side Probe | - | - | - | - | - | Spring Built-in | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Straight Crown | - | - | Copper Alloy | - |
From: ₹ 155.33 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probe / Receptacle (High Spring Pressure), 100 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package. | Full Stroke 6.4mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.5 | 2.54 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | - | Needle / Cup / Straight Crown / Waffle | - | - | Copper Alloy | - |
From: ₹ 97.93 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPE75 Series/NRE75 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package. | Full Stroke 6.4mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.5 | 1.91 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | - | Needle / Triangular Pyramid / Three-Needle / Cup / Straight Crown / Tapered Crown / Waffle | - | - | Copper Alloy | - |
From: ₹ 128.32 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probe / Receptacle (With Lead), 038 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 2mm
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 0.76 | One Side Probe | - | - | - | - | - | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Triangular Pyramid / Sphere Shape (SR) / Straight Crown | - | - | Copper Alloy | - |
From: ₹ 124.94 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probe / Receptacle (With Lead), 018 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 1mm
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 0.46 | One Side Probe | - | - | - | - | - | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Sphere Shape (SR) / Straight Crown | - | - | Copper Alloy | - |
From: ₹ 850.91 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPT1 Series/NRT1 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 2.54mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.67 ~ 1.5 | 1.91 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | - | - | Copper Alloy | - |
From: ₹ 41.56 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPT2 Series/NRT2 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 3.8mm | Number of Mounting Points Crowned Type: 4
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1.06 ~ 1.93 | 2.54 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | - | - | Copper Alloy | - |
From: ₹ 46.76 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes and Receptacles-NPE50 Series/NRE50 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 6.4mm | Number of Mounting Points Crowned Type: 9
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1.27 | One Side Probe | - | - | - | - | - | - | Nickel Plating Base, Gold Plating | - | Standard | Copper Alloy | - | Needle / Cup / Tapered Crown / Waffle | - | - | Copper Alloy | - |
From: ₹ 129.87 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probe / Receptacle (With Lead), 048 Series【50 Pieces Per Package】
MISUMI
Convenient and economical Bulk Package | Full Stroke 2mm
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 0.9 | One Side Probe | - | - | - | - | - | - | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Triangular Pyramid / Sphere Shape (SR) / Straight Crown | - | - | Copper Alloy | - |
From: ₹ 84.42 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Contact Probes, Receptacles【50 Pieces Per Package】
MISUMI
Plunger Outer Dia. D1(Ø) | Mounting Pitch(mm) | Type | Allowable Current(A) | Plunger Length L1 (Range)(mm) | End Shape | Barrel, Receptacle Outer Dia. D2(Ø) | Barrel, Receptacle Length L2 (Range)(mm) | Integrated Probe Type | Plunger Surface Treatment | Receptacle Outermost Dia. D (Range)(Ø) | Properties | Plunger Material | Resistance(mΩ) | Plunger Tip Shape | Stroke (Range)(mm) | 2/3 Stroke Spring Pressure (Range)(gf) | Barrel, Receptacle Material | Initial Spring Pressure (Range)(gf) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2.5 | 0.65 | One Side Probe | - | - | - | - | - | Spring Externally Mounted | Nickel Plating Base, Gold Plating | - | Standard | Carbon Steel | - | Needle / Sphere Shape (SR) / Tapered Crown | - | - | Copper Alloy | - |
From: ₹ 357.93 |
---|
Days to Ship: 6 Day(s) or more |
Brand |
---|
Product Series |
CAD |
From |
Days to Ship |
Specifications |
Plunger Outer Dia. D1(Ø) |
Mounting Pitch(mm) |
Type |
Allowable Current(A) |
Plunger Length L1 (Range)(mm) |
End Shape |
Barrel, Receptacle Outer Dia. D2(Ø) |
Barrel, Receptacle Length L2 (Range)(mm) |
Integrated Probe Type |
Plunger Surface Treatment |
Receptacle Outermost Dia. D (Range)(Ø) |
Properties |
Plunger Material |
Resistance(mΩ) |
Plunger Tip Shape |
Stroke (Range)(mm) |
2/3 Stroke Spring Pressure (Range)(gf) |
Barrel, Receptacle Material |
Initial Spring Pressure (Range)(gf) |
You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | |
Brand | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI |
Product Series | NP84 Series Contact Probes Min Pitch3.0mm, Stroke 6.3mm【50 Pieces Per Package】 | NP58 Series Contact Probes Min Pitch1.00mm, Stroke 2.0mm【50 Pieces Per Package】 | NP76 Series Contact Probes Min Pitch 1.27mm, Stroke 6.0mm【50 Pieces Per Package】 | Contact Probes and Receptacles-NPM156 Series/NRM156 Series【50 Pieces Per Package】 | NP88 Series Contact Probes Min Pitch 1.5mm, Stroke 2.5mm【50 Pieces Per Package】 | Contact Probe / Receptacle (With Lead), 058 Series【50 Pieces Per Package】 | NP120 Series Contact Probes Min Pitch 2.0mm, Stroke 6.5mm【50 Pieces Per Package】 | NP45 Series Contact Probes Min Pitch 1.7mm, Stroke 5.0mm【50 Pieces Per Package】 | Contact Probe / Receptacle (With Lead), 030 Series【50 Pieces Per Package】 | NP20 Series Contact Probes Min Pitch 0.9mm, Stroke 2.0mm【50 Pieces Per Package】 | Contact Probes and Receptacles-NPT0 Series/NRT0W Series【50 Pieces Per Package】 | Contact Probes and Receptacles-NPQ75 Series/NRQ75 Series/C-Value【50 Pieces Per Package】 | NP604 Series Contact Probes Min Pitch2.54mm, Stroke 4.0mm【50 Pieces Per Package】 | Contact Probes and Receptacles-NPQ50 Series/NRQ50 Series【50 Pieces Per Package】 | Contact Probe / Receptacle (Low Spring Pressure), 100 Series【50 Pieces Per Package】 | Contact Probes and Receptacles-NPM125 Series/NRM125 Series【50 Pieces Per Package】 | Contact Probe / Receptacle (High Spring Pressure), 100 Series【50 Pieces Per Package】 | Contact Probes and Receptacles-NPE75 Series/NRE75 Series【50 Pieces Per Package】 | Contact Probe / Receptacle (With Lead), 038 Series【50 Pieces Per Package】 | Contact Probe / Receptacle (With Lead), 018 Series【50 Pieces Per Package】 | Contact Probes and Receptacles-NPT1 Series/NRT1 Series【50 Pieces Per Package】 | Contact Probes and Receptacles-NPT2 Series/NRT2 Series【50 Pieces Per Package】 | Contact Probes and Receptacles-NPE50 Series/NRE50 Series【50 Pieces Per Package】 | Contact Probe / Receptacle (With Lead), 048 Series【50 Pieces Per Package】 | ||||||||||||||||||||
CAD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
From | ₹ 2,917.04- | ₹ 2,435.66- | ₹ 214.28- | ₹ 603.90- | ₹ 253.24 | ₹ 390.00- | ₹ 147.00- | ₹ 662.34- | ₹ 1,769.32- | ₹ 88.00- | ₹ 8,103.89 | ₹ 1,613.62- | ₹ 72.00- | ₹ 146.10- | ₹ 487.00- | ₹ 303.89 | ₹ 189.93 | ₹ 278.56 | ₹ 4,220.78 | ₹ 2,857.57- | ₹ 2,630.19- | ₹ 417.85 | ₹ 233.76- | ₹ 214.28- | ₹ 18,064.92 | ₹ 3,191.31- | ₹ 2,857.14- | ₹ 6,077.92- | ₹ 2,697.71- | ₹ 1,012.96 | ₹ 759.72 | ₹ 607.78 | ₹ 7,935.06 | ₹ 4,896.10- | ₹ 7,766.23 | ₹ 4,896.10- | ₹ 6,415.58- | ₹ 6,246.75 | ₹ 42,545.41 | ₹ 2,077.92- | ₹ 2,337.66- | ₹ 6,493.50- | ₹ 4,220.78 | ₹ 17,896.09 |
Days to Ship | Same day or more | 12 Day(s) or more | 6 Day(s) or more | Same day or more | 6 Day(s) or more | Same day or more | Same day or more | Same day or more | 12 Day(s) or more | Same day or more | 6 Day(s) or more | 12 Day(s) or more | Same day or more | Same day or more | 6 Day(s) or more | 6 Day(s) or more | Same day or more | 6 Day(s) or more | 6 Day(s) or more | 12 Day(s) or more | 12 Day(s) or more | 6 Day(s) or more | Same day or more | 6 Day(s) or more | 6 Day(s) or more | 12 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 12 Day(s) | 6 Day(s) or more | Same day or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more |
Specifications | ||||||||||||||||||||||||||||||||||||||||||||
Plunger Outer Dia. D1(Ø) | 1.25 ~ 2.54 | 0.38 ~ 0.8 | 0.69 ~ 1 | 1.5 ~ 4 | 0.48 ~ 1 | 1.3 ~ 2.54 | 0.68 ~ 1.5 | 1.96 ~ 3.95 | 0.5 ~ 1 | 1 ~ 1.9 | 2.5 | 0.67 ~ 1 | 1 ~ 2.4 | 0.68 ~ 1.3 | 0.29 ~ 0.4 | 0.54 ~ 0.9 | 0.93 ~ 1.5 | 1 | - | 0.93 ~ 1.5 | 0.75 ~ 1.3 | 0.42 ~ 0.8 | 0.48 ~ 1 | 0.49 ~ 1.2 | - | 0.35 ~ 0.5 | 2.5 | 2.5 | 0.99 ~ 1.9 | 0.15 ~ 0.3 | 0.21 ~ 0.34 | 0.37 ~ 0.5 | - | 2.5 | 2.03 | 2.5 | 2.5 | - | - | 0.67 ~ 1.5 | 1.06 ~ 1.93 | - | - | 2.5 |
Mounting Pitch(mm) | 3 | 1 | 1.5 | 3.5 ~ 4.5 | 1.27 | 3 | 1.7 | 4.5 | 1.27 | 2.54 | 3.96 | 1.5 | 2.54 | 1.7 | 0.8 | 1.27 | 2 | 1.27 | 1 | 2 | 1.7 | 1 | 1.27 | 1.4 | 0.55 | 0.9 | 1.27 | 1.91 | 2.54 | 0.5 | 0.6 | 0.9 | 1.27 | 2.54 | 3.18 | 2.54 | 1.91 | 0.76 | 0.46 | 1.91 | 2.54 | 1.27 | 0.9 | 0.65 |
Type | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe | One Side Probe |
Allowable Current(A) | 3 | 1.9 | 3 | 1.5 | 1 | 1.5 | 1.5 ~ 3 | 1.5 | 3 | 1.5 ~ 3 | - | 3 | 1.5 | 1.5 ~ 3 | 1 | 1 | 1.5 | 2 | - | 2.5 | 3 | 1 | 1.3 | 2.5 | - | 1.5 | - | - | 3 | 0.5 | 1 | 1 | - | - | - | - | - | - | - | - | - | - | - | - |
Plunger Length L1 (Range)(mm) | 8.1~12 | 0.1~3 ~ 3.1~5 | 3.1~5 | 8.1~12 | 3.1~5 | 8.1~12 | 3.1~5 | 8.1~12 | 5.1~8 | 5.1~8 | - | 3.1~5 | 8.1~12 ~ 12.1~15 | 5.1~8 | 0.1~3 ~ 3.1~5 | 3.1~5 | 8.1~12 | 5.1~8 | - | 8.1~12 | 3.1~5 ~ 5.1~8 | 0.1~3 ~ 3.1~5 | 5.1~8 | 5.1~8 | - | 0.1~3 ~ 5.1~8 | - | - | 5.1~8 | 0.1~3 ~ 3.1~5 | 0.1~3 ~ 3.1~5 | 0.1~3 ~ 3.1~5 | - | - | - | - | - | - | - | - | - | - | - | - |
End Shape | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Barrel, Receptacle Outer Dia. D2(Ø) | 2 | 0.58 | 0.88 | 2.33 | 0.68 | 2 | 1 | 3.18 | 0.76 | 1.37 | - | 0.88 | 1.37 | 1.02 | 0.38 | 0.72 | 1.2 | 0.68 | - | 1.2 | 1 ~ 1.02 | 0.58 | 0.76 | 0.68 | - | 0.48 | - | - | 1.37 | 0.26 | 0.31 | 0.48 | - | - | - | - | - | - | - | - | - | - | - | - |
Barrel, Receptacle Length L2 (Range)(mm) | 20.1~25 | 10.1~15 | 10.1~15 | 20.1~25 | 10.1~15 | 20.1~25 | 10.1~15 | 25.1~30 | 25.1~30 | 15.1~20 | - | 10.1~15 | 20.1~25 | 20.1~25 | 5~10 | 10.1~15 | 20.1~25 | 15.1~20 | - | 20.1~25 | 10.1~15 / 20.1~25 | 10.1~15 | 25.1~30 | 15.1~20 | - | 10.1~15 | - | - | 15.1~20 | 5~10 | 5~10 | 10.1~15 | - | - | - | - | - | - | - | - | - | - | - | - |
Integrated Probe Type | - | - | - | - | - | - | - | - | - | - | Spring Externally Mounted / Spring Built-in | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Spring Externally Mounted | Spring Externally Mounted | - | Spring Built-in | - | - | - | Spring Externally Mounted | Spring Built-in | Spring Externally Mounted | Spring Externally Mounted | - | - | Spring Externally Mounted | Spring Externally Mounted | - | - | Spring Externally Mounted |
Plunger Surface Treatment | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Rhodium Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating | Nickel Plating Base, Gold Plating |
Receptacle Outermost Dia. D (Range)(Ø) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Properties | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard |
Plunger Material | Copper Alloy | Carbon Steel | Carbon Steel | Copper Alloy | Copper Alloy / Carbon Steel | Copper Alloy | Copper Alloy / Carbon Steel | Copper Alloy | Copper Alloy | Copper Alloy | Carbon Steel | Carbon Steel | Copper Alloy / Carbon Steel | Copper Alloy / Carbon Steel | Carbon Steel | Carbon Steel | Carbon Steel | Carbon Steel | Carbon Steel | Carbon Steel | Copper Alloy | Carbon Steel | Copper Alloy | Carbon Steel | Carbon Steel | Carbon Steel | Carbon Steel | Copper Alloy | Copper Alloy | Carbon Steel | Carbon Steel | Copper Alloy / Carbon Steel | Carbon Steel | Carbon Steel | Carbon Steel | Copper Alloy | Copper Alloy | Carbon Steel | Carbon Steel | Carbon Steel | Carbon Steel | Copper Alloy | Carbon Steel | Carbon Steel |
Resistance(mΩ) | 50 | 70 | 60 ~ 80 | 80 | 100 | 80 | 60 ~ 80 | 80 | 60 | 80 | - | 60 | 80 | 60 ~ 80 | 180 | 80 | 80 | 80 | - | 60 | 60 | 100 | 80 | 60 ~ 80 | - | 80 | - | - | 50 | 200 | 180 | 100 | - | - | - | - | - | - | - | - | - | - | - | - |
Plunger Tip Shape | - | - | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | Needle / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | Needle / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Waffle | Needle / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | - | Needle / Sphere Shape (SR) / Cup / Waffle | Needle / Cup / Straight Crown / Waffle | - | Needle / Three-Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Waffle | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown / Waffle | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Waffle | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Flat / Waffle | Needle / Triangular Pyramid / Sphere Shape (SR) / Tapered Crown | - | - | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | Needle / Cup / Straight Crown / Tapered Crown / Waffle | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Flat / Tapered Crown / Waffle | Needle / Sphere Shape (SR) / Straight Crown | - | Needle / Triangular Pyramid / Sphere Shape (SR) / Cup / Straight Crown / Tapered Crown | Needle / Triangular Pyramid / Cup / Straight Crown / Tapered Crown | - | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown / Tapered Crown | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | Needle / Cup / Tapered Crown / Waffle | Needle / Cup / Straight Crown / Waffle | Needle / Straight Crown | Needle / Cup / Straight Crown / Waffle | Needle / Triangular Pyramid / Three-Needle / Cup / Straight Crown / Tapered Crown / Waffle | Needle / Triangular Pyramid / Sphere Shape (SR) / Straight Crown | Needle / Sphere Shape (SR) / Straight Crown | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | Needle / Sphere Shape (SR) / Cup / Flat / Straight Crown | Needle / Cup / Tapered Crown / Waffle | Needle / Triangular Pyramid / Sphere Shape (SR) / Straight Crown | Needle / Sphere Shape (SR) / Tapered Crown |
Stroke (Range)(mm) | 5~6.5 | 1~2.6 | 1~2.6 | 5~6.5 | 1~2.6 | 5~6.5 | 3~4.5 | 5~6.5 | 5~6.5 | 3~4.5 | - | 1~2.6 | 5~6.5 | 5~6.5 | 1~2.6 | 1~2.6 | 5~6.5 | 3~4.5 | - | 5~6.5 | 3~4.5 / 5~6.5 | 1~2.6 | 5~6.5 | 3~4.5 | - | 1~2.6 / 3~4.5 | - | - | 3~4.5 | 1~2.6 | 1~2.6 | 1~2.6 / 3~4.5 | - | - | - | - | - | - | - | - | - | - | - | - |
2/3 Stroke Spring Pressure (Range)(gf) | 30.1~50 / 100.1~150 / 150.1~200 | 30.1~50 | 30.1~50 / 50.1~100 | 30.1~50 / 100.1~150 / 200.1~300 | 30.1~50 / 50.1~100 | 30.1~50 / 100.1~150 / 150.1~200 | 30.1~50 / 50.1~100 | 50.1~100 / 200.1~300 / 300.1~ | 100.1~150 | 50.1~100 / 100.1~150 / 150.1~200 | - | 30.1~50 / 50.1~100 | 30.1~50 / 50.1~100 / 100.1~150 / 150.1~200 | 30.1~50 / 50.1~100 / 100.1~150 | 30.1~50 | 30.1~50 / 50.1~100 | 30.1~50 / 50.1~100 | 30.1~50 / 50.1~100 | - | 30.1~50 / 50.1~100 | 30.1~50 / 50.1~100 / 100.1~150 | 30.1~50 | 100.1~150 | 30.1~50 / 50.1~100 | - | 30.1~50 | - | - | 100.1~150 / 150.1~200 | 0~30 | 0~30 | 30.1~50 | - | - | - | - | - | - | - | - | - | - | - | - |
Barrel, Receptacle Material | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy | Copper Alloy |
Initial Spring Pressure (Range)(gf) | 0~10 ~ 50.1~100 | 20.1~30 | 0~10 ~ 20.1~30 | 0~10 ~ 100.1~200 | 0~10 ~ 30.1~50 | 0~10 ~ 50.1~100 | 20.1~30 | 20.1~30 ~ 100.1~200 | 50.1~100 | 0~10 ~ 30.1~50 | - | 0~10 ~ 20.1~30 | 10.1~20 ~ 20.1~30 | 0~10 ~ 30.1~50 | 10.1~20 | 10.1~20 ~ 20.1~30 | 10.1~20 ~ 20.1~30 | 20.1~30 | - | 10.1~20 ~ 20.1~30 | 0~10 ~ 30.1~50 | 20.1~30 | 50.1~100 | 20.1~30 | - | 10.1~20 | - | - | 0~10 ~ 30.1~50 | 0~10 | 0~10 | 10.1~20 | - | - | - | - | - | - | - | - | - | - | - | - |