MISUMI Insulation Wires for Electric / Electronic / Communication Equipment

Insulation Wires for Electric / Electronic / Communication Equipment products in the Wiring Components category from MISUMI. The product can be selected based on many product specifications such as Conductor Cross Section, AWG size, Sheath (outer coating) color, Rated Voltage, Properties. MISUMI offers products around 4 items and the product specifications can easily be compared. Equipment and parts for electrical systems, cables and electrical connections. MISUMI products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • Others

4 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable

    FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable

    MISUMI

    600 V heat-resistant single core wire. Tin-plated and annealed copper stranded wire is used for the conductor, so the continuous operating temperature is -60°C to 150°C.

    • PSE Law
    • For Power Supply
    • Connection in Boards
    • Heat-Resistant
    • Cold-Resistant
    • Strand Wire
    • 600 V
    Conductor Cross Section(mm2) AWG size(AWG) Sheath (outer coating) color Rated Voltage Properties Overall Length(m) Finished outer diameter(mm) Representative Standard Insulation body materials Shield Logarithm Sheath (outer coating) material
    0.75 ~ 3.5 12 ~ 18 Black / White / Red / Yellow / Green / Blue / Other 600V Heat-Resistance / Cold Resistance / Chemical Resistance 10 ~ 200 1.9 ~ 3.3 PSE - NA - Other
    From: ₹ 1,571.20
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Cable NA400 250 V 400 °C Heat-Resistant

    Cable NA400 250 V 400 °C Heat-Resistant

    MISUMI

    Super heat-resistant single core wire for low-current circuits. It is braided with silica glass fiber and coated with polyimide paint and baked to form an insulator.

    • Heat-Resistant
    • Strand Wire
    Conductor Cross Section(mm2) AWG size(AWG) Sheath (outer coating) color Rated Voltage Properties Overall Length(m) Finished outer diameter(mm) Representative Standard Insulation body materials Shield Logarithm Sheath (outer coating) material
    - - - - - 1 ~ 99 - - - - - -
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Cable NAUL1283 / NAUL1284 UL Supported

    Cable NAUL1283 / NAUL1284 UL Supported

    MISUMI

    600 V international standard single core wire. You can purchase in units of 1 m.

    • CSA
    • VW-1
    • ULAWM
    • For Power Supply
    • Heat-Resistant
    • Strand Wire
    • 600 V
    Conductor Cross Section(mm2) AWG size(AWG) Sheath (outer coating) color Rated Voltage Properties Overall Length(m) Finished outer diameter(mm) Representative Standard Insulation body materials Shield Logarithm Sheath (outer coating) material
    8 ~ 87 1 ~ 8 Black / White / Red / Green / Blue / Other 600V Heat-Resistance 1 ~ 153 7.2 ~ 18.4 UL / CSA(c-UL) - NA - PVC (Polyvinyl Chloride)
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Cable KQE 60 V Cross-linked Polyethylene Insulation

    Cable KQE 60 V Cross-linked Polyethylene Insulation

    MISUMI

    • KQE Low voltage single core cable.
    • Conductor structure is Tin Plated Annealed Copper Stranded Wire
    • Insulated cable is Cross-linked Polyethylene material as RoHS complied wires.
    • 60V cable for weak current circuit.
    • Operating temperature range is 0-80℃.
    • 6 cable colors are available W (White), BK (Black), R (Red), BE (Blue), Y (Yellow) and GN (Green)
    • Can order cable for 4 sizes of length. (10m, 50m, 100m and 400m)
    • Minimum bending radius is 8 times of finished outer diameter. (Fixed Part Only)

    • Strand Wire
    • Less than 100 V
    Conductor Cross Section(mm2) AWG size(AWG) Sheath (outer coating) color Rated Voltage Properties Overall Length(m) Finished outer diameter(mm) Representative Standard Insulation body materials Shield Logarithm Sheath (outer coating) material
    0.75 18 Red For Low Current Circuits - 10 ~ 400 1.7 - - NA - Other
    From: ₹ 2,194.51
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
Brand
Product Series
From
Days to Ship
Specifications
Conductor Cross Section(mm2)
AWG size(AWG)
Sheath (outer coating) color
Rated Voltage
Properties
Overall Length(m)
Finished outer diameter(mm)
Representative Standard
Insulation body materials
Shield
Logarithm
Sheath (outer coating) material

You can add up to 6 items per a category to the compare list.

FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable

    You can add up to 6 items per a category to the compare list.

    Cable NA400 250 V 400 °C Heat-Resistant

      You can add up to 6 items per a category to the compare list.

      Cable NAUL1283 / NAUL1284 UL Supported

        You can add up to 6 items per a category to the compare list.

        Cable KQE 60 V Cross-linked Polyethylene Insulation
          Brand

          MISUMI

          MISUMI

          MISUMI

          MISUMI

          Product Series

          FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable

          Cable NA400 250 V 400 °C Heat-Resistant

          Cable NAUL1283 / NAUL1284 UL Supported

          Cable KQE 60 V Cross-linked Polyethylene Insulation

          From

          ₹ 1,571.20-

          --

          ₹ 2,194.51-

          Days to Ship 6 Day(s) or more 6 Day(s) or more 6 Day(s) or more 6 Day(s) or more
          Specifications
          • PSE Law
          • For Power Supply
          • Connection in Boards
          • Heat-Resistant
          • Cold-Resistant
          • Strand Wire
          • 600 V
          • Heat-Resistant
          • Strand Wire
          • CSA
          • VW-1
          • ULAWM
          • For Power Supply
          • Heat-Resistant
          • Strand Wire
          • 600 V
          • Strand Wire
          • Less than 100 V
          Conductor Cross Section(mm2)0.75 ~ 3.5-8 ~ 870.75
          AWG size(AWG)12 ~ 18-1 ~ 818
          Sheath (outer coating) colorBlack / White / Red / Yellow / Green / Blue / Other-Black / White / Red / Green / Blue / OtherRed
          Rated Voltage600V-600VFor Low Current Circuits
          PropertiesHeat-Resistance / Cold Resistance / Chemical Resistance-Heat-Resistance-
          Overall Length(m)10 ~ 2001 ~ 991 ~ 15310 ~ 400
          Finished outer diameter(mm)1.9 ~ 3.3-7.2 ~ 18.41.7
          Representative StandardPSE-UL / CSA(c-UL)-
          Insulation body materials----
          ShieldNA-NANA
          Logarithm----
          Sheath (outer coating) materialOther-PVC (Polyvinyl Chloride)Other

          Loading...

          1. 1

          Related Categories to Insulation Wires for Electric / Electronic / Communication Equipment

          FAQ Wire Cable

          Question: How many types of wires are there and how to choose the right wires?
          Answer: Cable can be separated into 2 types.
          1. Low voltage cable which using for electric system with voltage 750V or less. Typically, this type of cables is made of copper or aluminum such as THW, VAF, VCT and NYY.
          2. High voltage cable which using for electric system with voltage 1kV-36kV, conduct structure are stranded wire such as Aluminum Conductor (AAC), Aluminum Alloy Conductor (AAAC), Aluminum Conductor Steel Reinforced (ACSR), Partial Insulated Cable (PIC), Space Aerial Cable (SAC), Preassembly Aerial Cable (PAC) and Cross-linked Polyethylene (XLPE)
          Cable should select based on using electrical voltage and current. Moreover, we should select cable insulation which suit for operating environment such as Heat resistance, weather resistance or chemical resistance.
          Question: What are the components in the cable?
          Answer: Cable components are consisting of 3 parts as below.
          1. Conductor
          Made of metal wire, use for transmitting the electricity.
          2. Insulator
          Insulator is the component which is cover conductor wire to block electricity from conductor transmit to another part.
          3. Sheath
          The outer cover of cable use for protecting any harm to cable inside such as scratch, weather, and heat.
          Question: What types of wires are used in households?
          Answer: Cable for home appliance is low voltage cable type which is applicable for voltage 750V or less such as,
          1. THW cable, which consist of solid-core conductor wire with PVC insulator. Suit for wiring inside the building.
          2. VHF cable, which consist of multiple solid-core conductor wire with colored insulator inside white sheath. Suit for wiring inside the building.
          3. VCT cable, which consist of multiple stranded conductor wire with insulator inside the black sheath. Due to, heat and water resistance properties, this cable can be wiring outside the building. However, it cannot not wire directly underneath the ground. I should wire through electrical conduit pipe.
          Question: What applications are 1.5 mm wires suitable for?
          Answer: 1.5 mm2 is suit for general electrical home appliance which using current not exceed 15A and power does not exceed 3.5 kW.
          Question: Why are there different colors of wires?
          Answer: Electrical wires are identified by their insulating casings. To identify wires quickly and easily, nearly all electrical and electronic devices use color-coding.
          A live or hot circuit is typically black or red, but yellow or blue are also suitable.
          Neutral wires can be gray or white.
          Ground wires can be green, green with yellow stripes, or bare copper.
          Due to the colors' variability, learning the ropes can be confusing. When installing a new light fixture or during a blackout, you might find it helpful to know the meaning of the colors. Electric wires carry high voltages that may cause injury if you are not careful.
          X