KAMADASIGNAL Transformers(Secondary voltage:AC100-110)

KAMADASIGNAL offers products Transformers specified by Secondary voltage AC100-110 from Electrical & Controls product category. There are a total of 1 items. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies KAMADASIGNAL products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 12 Day(s) or Less
  • 13 Day(s) or Less
  • 15 Day(s) or Less
  • Others

1 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Singe-Phase Single-Winding Transformer, STP-A series

    Singe-Phase Single-Winding Transformer, STP-A series

    KAMADASIGNAL

    [Attention]
    · Picture is representative image.
    · Made by Kamata signal machine
    · Capacity is series of 100VA to 10KVA.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    AC200-220 0.1 ~ 0.5 AC100-110 Single-phase/single-winding A type Screw terminal block 87 ~ 109 NA NA 79 ~ 106 88 ~ 118
    From: ₹ 3,599.47
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
From
Days to Ship
Primary voltage(V)
Capacity(kVA)
Secondary voltage(V)
Number of phases/winding
Insulation type
Input/output terminal shape
Dimension vertical(mm)
Shield presence
With/without Case
Dimension width(mm)
Dimension depth(mm)

You can add up to 6 items per a category to the compare list.

Singe-Phase Single-Winding Transformer, STP-A series
    Brand

    KAMADASIGNAL

    Product Series

    Singe-Phase Single-Winding Transformer, STP-A series

    From

    ₹ 3,599.47-

    Days to Ship 5 Day(s) or more
    Primary voltage(V)AC200-220
    Capacity(kVA)0.1 ~ 0.5
    Secondary voltage(V)AC100-110
    Number of phases/windingSingle-phase/single-winding
    Insulation typeA type
    Input/output terminal shapeScrew terminal block
    Dimension vertical(mm)87 ~ 109
    Shield presenceNA
    With/without CaseNA
    Dimension width(mm)79 ~ 106
    Dimension depth(mm)88 ~ 118

    Loading...

    1. 1

    Related Categories to Transformers

    FAQ Transformers

    Question: What is the difference between 1 phase transformers and 3 phase transformers.
    Answer: 1. In a single-phase transformer, the electricity is supplied through two wires called Line and neutral. In three phase transformers, the electricity is supplied through three wires (four wires if neutral wire is included).
    2. The voltage of single-phase transformer supply is 230V whereas three-phase transformer supply is 415V.
    3. The efficiency of a three-phase transformer is significantly higher than a single-phase supply and the power transfer capability is also more.
    Question: How many types of transformers?
    Answer: Type of transformer can be separated by different types of applications.
    1. Transformer types based on core structure.
       1.1) Iron core transformer
       1.2) Shell core transformer
       1.3) H-type core transformer
    2. Transformer types based on electric system.
       2.1) Single-phase transformer
       2.2) Three-phase transformer
    3. Transformer types based on voltage level.
       3.1) Step-up transformer which is use for boost voltage up then transmit to secondary side.
       3.2) Step-down transformer which is use for reducing voltage down then transmit to secondary side.
       3.3) Isolation transformer which voltage at primary and secondary side are same. Typically, applicable for Laboratory which is need stable voltage and current.
    Question: What is transformer maintenance method?
    Answer: 1. Should install and using in low-humidity to prevent short circuit issue.
    2. Installation place should be good for heat transfer.
    3. Always keep cleaning heat transfer component.
    4. Always keep inspection terminal and wire.
    Question: Why transformer is necessary?
    Answer: Transformers is necessary because each electric device need different level of voltage. So, we must use transformer to adjust the electrical voltage from power source to sub-unit. Such as, reduce voltage from high-power electric post to the building and transformer for reduce voltage level from electric source of building to each electrical home appliance as well.