(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Please note that the MISUMI India offices and warehouses will remain closed from Oct 31st to Nov 3rd due to the Diwali festival.
    Please note that the MISUMI Pune office and warehouse will be closed on November 20th due to the state election.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

HITACHI CABLE Insulation Wires for Electric / Electronic / Communication Equipment(Rated Voltage:For High Voltages)

HITACHI CABLE offers products Insulation Wires for Electric / Electronic / Communication Equipment specified by Rated Voltage For High Voltages from Wiring Components product category. There are a total of 1 items. Equipment and parts for electrical systems, cables and electrical connections. HITACHI CABLE products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • Others

1 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Flame Retardant Polyflex Cable MLFC Series, 600 V / 1500 V

    Flame Retardant Polyflex Cable MLFC Series, 600 V / 1500 V

    HITACHI CABLE

    [Features]
    · Excellent heat resistance (110°C) and flame retardance.
    · Excellent flexibility.
    · Terminals are easily removable.

    Conductor Cross Section(mm2) AWG size(AWG) Sheath (outer coating) color Rated Voltage Properties Overall Length(m) Finished outer diameter(mm) Representative Standard Insulation body materials Shield Logarithm Sheath (outer coating) material
    2 ~ 5.5 - - For High Voltages Heat-Resistance / Cold Resistance 1 ~ 100 6.5 ~ 7.8 - Fluorine-Based NA - -
    From: ₹ 339.99
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
From
Days to Ship
Conductor Cross Section(mm2)
AWG size(AWG)
Sheath (outer coating) color
Rated Voltage
Properties
Overall Length(m)
Finished outer diameter(mm)
Representative Standard
Insulation body materials
Shield
Logarithm
Sheath (outer coating) material

You can add up to 6 items per a category to the compare list.

Flame Retardant Polyflex Cable MLFC Series, 600 V / 1500 V
    Brand

    HITACHI CABLE

    Product Series

    Flame Retardant Polyflex Cable MLFC Series, 600 V / 1500 V

    From

    ₹ 339.99-

    Days to Ship 5 Day(s) or more
    Conductor Cross Section(mm2)2 ~ 5.5
    AWG size(AWG)-
    Sheath (outer coating) color-
    Rated VoltageFor High Voltages
    PropertiesHeat-Resistance / Cold Resistance
    Overall Length(m)1 ~ 100
    Finished outer diameter(mm)6.5 ~ 7.8
    Representative Standard-
    Insulation body materialsFluorine-Based
    ShieldNA
    Logarithm-
    Sheath (outer coating) material-

    Loading...

    1. 1

    Related Categories to Insulation Wires for Electric / Electronic / Communication Equipment

    FAQ Wire Cable

    Question: How many types of wires are there and how to choose the right wires?
    Answer: Cable can be separated into 2 types.
    1. Low voltage cable which using for electric system with voltage 750V or less. Typically, this type of cables is made of copper or aluminum such as THW, VAF, VCT and NYY.
    2. High voltage cable which using for electric system with voltage 1kV-36kV, conduct structure are stranded wire such as Aluminum Conductor (AAC), Aluminum Alloy Conductor (AAAC), Aluminum Conductor Steel Reinforced (ACSR), Partial Insulated Cable (PIC), Space Aerial Cable (SAC), Preassembly Aerial Cable (PAC) and Cross-linked Polyethylene (XLPE)
    Cable should select based on using electrical voltage and current. Moreover, we should select cable insulation which suit for operating environment such as Heat resistance, weather resistance or chemical resistance.
    Question: What are the components in the cable?
    Answer: Cable components are consisting of 3 parts as below.
    1. Conductor
    Made of metal wire, use for transmitting the electricity.
    2. Insulator
    Insulator is the component which is cover conductor wire to block electricity from conductor transmit to another part.
    3. Sheath
    The outer cover of cable use for protecting any harm to cable inside such as scratch, weather, and heat.
    Question: What types of wires are used in households?
    Answer: Cable for home appliance is low voltage cable type which is applicable for voltage 750V or less such as,
    1. THW cable, which consist of solid-core conductor wire with PVC insulator. Suit for wiring inside the building.
    2. VHF cable, which consist of multiple solid-core conductor wire with colored insulator inside white sheath. Suit for wiring inside the building.
    3. VCT cable, which consist of multiple stranded conductor wire with insulator inside the black sheath. Due to, heat and water resistance properties, this cable can be wiring outside the building. However, it cannot not wire directly underneath the ground. I should wire through electrical conduit pipe.
    Question: What applications are 1.5 mm wires suitable for?
    Answer: 1.5 mm2 is suit for general electrical home appliance which using current not exceed 15A and power does not exceed 3.5 kW.
    Question: Why are there different colors of wires?
    Answer: Electrical wires are identified by their insulating casings. To identify wires quickly and easily, nearly all electrical and electronic devices use color-coding.
    A live or hot circuit is typically black or red, but yellow or blue are also suitable.
    Neutral wires can be gray or white.
    Ground wires can be green, green with yellow stripes, or bare copper.
    Due to the colors' variability, learning the ropes can be confusing. When installing a new light fixture or during a blackout, you might find it helpful to know the meaning of the colors. Electric wires carry high voltages that may cause injury if you are not careful.
    X
    whatsapp-qr whatsapp-icon