(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:30 15/12/2024 to 3:30 (IST) 16/12/2024. We apologize for the inconvenience.
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

RITTAL Electrical Enclosure Cooling Fans(Representative Standard:CSA)

RITTAL offers products Electrical Enclosure Cooling Fans specified by Representative Standard CSA from Electrical & Controls product category. There are a total of 2 items. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies RITTAL products are available to order through MISUMI online 24 hours a day. Free shipping, no minimum order.

Show More Detail Show More Detail

CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • Others

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    Filter Fan

    Filter Fan

    RITTAL

    This is a complete fan unit that can be attached to a surface without tools.

    [Paint color]
    · RAL 7035 (light gray [approximate Munsell value 2.5PB8.5/1])
    [Bundled items]
    · Complete assembled unit (including filter mat)

    Type Input Voltage Size Thickness Properties Sensor output Representative Standard Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min) Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min) Maximum air flow (DC input voltage)(m3/min) Volume (DC input voltage)(dB) Volume (AC input voltage, 50 Hz)(dB) Volume (AC input voltage, 60Hz)(dB) Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa) Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa) Maximum static pressure (DC input voltage)(Pa)
    AC fan / DC Fan DC24V / Other Other Other - - CSA 20 ~ 700 25 ~ 770 20 ~ 230 38 ~ 54 38 ~ 65 43 ~ 66 - - -
    From: ₹ 9,706.58
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Filter Fan Using EC Technology

    Filter Fan Using EC Technology

    RITTAL

    Energy-efficient TopTherm Filter Fan, featuring diagonal fan technology

    The control interface with tacho signal output lets you activate the fan and monitor its rotation speed and features.

    [Paint color]
    · RAL 7035 (light gray [approximate Munsell value 2.5PB8.5/1])
    [Bundled items]
    · Complete assembled unit (including filter mat)

    Type Input Voltage Size Thickness Properties Sensor output Representative Standard Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min) Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min) Maximum air flow (DC input voltage)(m3/min) Volume (DC input voltage)(dB) Volume (AC input voltage, 50 Hz)(dB) Volume (AC input voltage, 60Hz)(dB) Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa) Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa) Maximum static pressure (DC input voltage)(Pa)
    AC fan Other Other Other - - CSA 55 ~ 180 55 ~ 180 - - 47 ~ 53 47 ~ 53 - - -
    From: ₹ 23,137.78
    Days to Ship: 8 Day(s) or more
    day to ship 8 Day(s) or more
Brand
Product Series
From
Days to Ship
Type
Input Voltage
Size
Thickness
Properties
Sensor output
Representative Standard
Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min)
Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min)
Maximum air flow (DC input voltage)(m3/min)
Volume (DC input voltage)(dB)
Volume (AC input voltage, 50 Hz)(dB)
Volume (AC input voltage, 60Hz)(dB)
Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa)
Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa)
Maximum static pressure (DC input voltage)(Pa)

You can add up to 6 items per a category to the compare list.

Filter Fan

    You can add up to 6 items per a category to the compare list.

    Filter Fan Using EC Technology
      Brand

      RITTAL

      RITTAL

      Product Series

      Filter Fan

      Filter Fan Using EC Technology

      From

      ₹ 9,706.58-

      ₹ 23,137.78-

      Days to Ship 6 Day(s) or more 8 Day(s) or more
      TypeAC fan / DC FanAC fan
      Input VoltageDC24V / OtherOther
      SizeOtherOther
      ThicknessOtherOther
      Properties--
      Sensor output--
      Representative StandardCSACSA
      Maximum Air Flow (AC Input Voltage, when 50 Hz)(m3/min)20 ~ 70055 ~ 180
      Maximum Air Flow (AC Input Voltage, when 60Hz)(m3/min)25 ~ 77055 ~ 180
      Maximum air flow (DC input voltage)(m3/min)20 ~ 230-
      Volume (DC input voltage)(dB)38 ~ 54-
      Volume (AC input voltage, 50 Hz)(dB)38 ~ 6547 ~ 53
      Volume (AC input voltage, 60Hz)(dB)43 ~ 6647 ~ 53
      Maximum Static Pressure (AC Input Voltage, 50 Hz)(Pa)--
      Maximum Static Pressure (AC Input Voltage, 60Hz)(Pa)--
      Maximum static pressure (DC input voltage)(Pa)--

      Loading...

      1. 1

      Related Categories to Electrical Enclosure Cooling Fans

      FAQ Fans

      Question: What distinguishes an industrial fan from a standard equipment fan, and what applications are they used for?
      Answer:
      Items Industrial Fan Standard Equipment Fan
      Design and Construction Robust, heavy-duty materials Compact, designed for power supply units
      Size Larger sizes Varied sizes
      Performance High airflow capacity, variable speeds Efficient cooling for power supplies
      Applications Ventilation, process cooling in industries Cooling power supply units and electronic equipment
      Specialized Types Centrifugal, axial fans Designed for power supply applications
      Noise Levels Can be noisy Designed for quiet operation

      In summary, industrial fans excel in heavy-duty ventilation, while standard equipment power supply fans are specialized for cooling power supply units in various electronic equipment, emphasizing compact designs and quieter operation.

      Question: How do AC and DC fans differ in functionality, and which is more suitable for electrical control systems?
      Answer: AC and DC fans differ in their motor type and power source. AC fans use alternating current motors, while DC fans use direct current motors. AC fans are more common and less expensive, but they are also less energy efficient than DC fans. DC fans can be controlled more precisely, making them a better choice for applications where consistent airflow is crucial. Additionally, DC fans can handle lower voltage and can be used in a wider range of applications.

      In terms of suitability for electrical control systems, DC fans are generally more suitable. This is because they offer greater controllability, energy efficiency, and compatibility with a wider range of control systems. DC fans are often used in applications such as CNC machines, robotics, and industrial automation.
      Question: Can you explain how cooling fans contribute to the maintenance and performance of machinery?
      Answer: Cooling fans play a vital role in maintaining the performance and extending the lifespan of machinery by effectively removing excess heat generated during operation. Overheating can lead to component damage, reduced efficiency, and premature equipment failure. Cooling fans actively circulate air around the machinery, dissipating heat and preventing overheating. This consistent cooling helps maintain optimal operating temperatures, ensuring smooth operation, consistent performance, and reduced wear and tear.
      Question: What are the benefits of using energy-efficient cooling solutions for industrial equipment, and what options does MISUMI Thailand offer?
      Answer: Implementing energy-efficient cooling solutions for industrial equipment offers a multitude of benefits, including:
      1.Reduced Energy Consumption: Significant energy savings, lowering operational costs and environmental impact.
      2.Extended Equipment Lifespan: Reduced wear and tear, minimizing downtime and maintenance expenses.
      3.Improved Process Efficiency: Optimized cooling ensures consistent performance and product quality.
      4.Enhanced Safety: Reduced risk of overheating and potential hazards.

      MISUMI Thailand provides a comprehensive range of energy-efficient cooling solutions for industrial equipment, including High-efficiency Fans. which Low-energy consumption fans with optimized airflow for various applications.
      Question: In what ways are waterproof and oilproof fans critical to the operations of industrial environments?
      Answer: Waterproof and oilproof fans play a crucial role in industrial settings due to their ability to withstand harsh environmental conditions and maintain optimal performance. These fans are essential for applications involving water exposure, dust, and airborne contaminants, ensuring proper ventilation and temperature control in various industrial environments, including manufacturing plants, power plants, and chemical processing facilities.
      Question: How has technology advanced the control and efficiency of electric fans used in mechanical ventilation?
      Answer: Technology has revolutionized the control and efficiency of electric cooling fans in mechanical ventilation systems, leading to more intelligent, adaptable, and energy-efficient systems. These advancements encompass various aspects, including smart sensors, Variable Frequency Drives (VFDs), improved blade designs, energy-efficient motors, remote monitoring, and Artificial Intelligence (AI) integration.
      X