(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Cable Glands(Material:Resin Page2)

A cable gland is a part that secures the cable and protects it from cable disconnection and load due to vibration, and prevents water, oil, and dust from entering the insertion port. Used for cable outlets of electrical wiring devices such as control panels, junction boxes, handy controllers, etc. After inserting the cable into the connector body, fix and connect it with a rubber bush that serves as an internal seal, a lock nut, and a seal nut. The most common type is a tool that can be hand tightened without using tools, and there are parts for various sizes and applications. The material is made of polyamide, which has excellent waterproof properties, NBR rubber, which is resistant to oil, silicon rubber, which is resistant to aging and ultraviolet rays, metal, which is resistant to chemicals and impact, etc. There are also parts with different shapes from general-purpose types, such as spiral and pinch types that prevent cable breakage, etc.
CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 9 Day(s) or Less
  • Others

48 items

Sort By
  • You can add up to 6 items per a category to the compare list.

    Bushing Cable Gland

    Bushing Cable Gland

    AVC

    By cutting off the first stage or the second stage of the cable protection part, compatibility with each cable diameter can be achieved.

    [Features]
    Because the product is integrated, the cost is lowered and by removing the cable protection part (AB part), the product can be adapted to a variety of different cable sizes.

    Shape Outer Diameter Of Cable Used Screw Standard Material Color Protection Function (Environmental Resistance) Representative Standard Type Screw Size
    Integrated Type Φ5/7/9 ~ Φ8/Φ10/Φ12 G (PF) Thread Resin Black - - Cable Gland G(PF) 1/2"
    From: ₹ 164.96
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Multiple Model Cable Gland, Gland Body, KDL Series

    Multiple Model Cable Gland, Gland Body, KDL Series

    MURRPLASTIK

    This is a cable gland (main body) that enables multiple linked cables to be mounted in a narrow space.

    Shape Outer Diameter Of Cable Used Screw Standard Material Color Protection Function (Environmental Resistance) Representative Standard Type Screw Size
    Multiple Type (Square) Φ5~16 ~ ø16 to 18 (Large Bore), 5 to 16 (Small Bore) - Resin Black Waterproof - Cable Gland -
    From: ₹ 2,688.56
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Cable Gland For THA45 Type Cable Ground

    Cable Gland For THA45 Type Cable Ground

    TAKACHI ELECTRONICS ENCLOSURE

    [Features]
    · Main body integrated with a rubber bushing structure that does not have any gaps providing superior waterproofing characteristics.

    • Volume Discount
    CAD :
    2D
    Shape Outer Diameter Of Cable Used Screw Standard Material Color Protection Function (Environmental Resistance) Representative Standard Type Screw Size
    Integrated Type Φ6×2mm ~ Φ7.5~9.5mm Metric Thread Resin Other Waterproof CE - -
    From: ₹ 434.00
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
CAD
From
Days to Ship
Shape
Outer Diameter Of Cable Used
Screw Standard
Material
Color
Protection Function (Environmental Resistance)
Representative Standard
Type
Screw Size

    You can add up to 6 items per a category to the compare list.

    Bushing Cable Gland

        You can add up to 6 items per a category to the compare list.

        Multiple Model Cable Gland, Gland Body, KDL Series

            You can add up to 6 items per a category to the compare list.

            Cable Gland For THA45 Type Cable Ground
              Brand

              AVC

              MURRPLASTIK

              TAKACHI ELECTRONICS ENCLOSURE

              Product Series

              Bushing Cable Gland

              Multiple Model Cable Gland, Gland Body, KDL Series

              Cable Gland For THA45 Type Cable Ground

              CAD
              • 2D
              From

              ₹ 164.96

              ₹ 2,688.56

              ₹ 434.00

              Days to Ship 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more
              ShapeIntegrated TypeMultiple Type (Square)Integrated Type
              Outer Diameter Of Cable UsedΦ5/7/9 ~ Φ8/Φ10/Φ12Φ5~16 ~ ø16 to 18 (Large Bore), 5 to 16 (Small Bore)Φ6×2mm ~ Φ7.5~9.5mm
              Screw StandardG (PF) Thread-Metric Thread
              MaterialResinResinResin
              ColorBlackBlackOther
              Protection Function (Environmental Resistance)-WaterproofWaterproof
              Representative Standard--CE
              TypeCable GlandCable Gland-
              Screw SizeG(PF) 1/2"--

              Loading...

              Related Categories to Cable Glands

              FAQ Cable Glands

              Question: What are cable glands?
              Answer: Cable glands are mechanical devices used to secure and protect the ends of cables. They are primarily used to provide a safe connection between electrical cables and equipment, ensuring protection against environmental elements like dust, water, and contaminants. Cable glands are essential in both industrial and commercial electrical installations.
              Question: How do I choose the right cable gland?
              Answer: When selecting a cable gland, consider the following factors:
              • Cable type: The gland must be compatible with the cable's size and type.
              • Environment: The gland should be suitable for the operating environment, such as indoor, outdoor, or hazardous areas.
              • Protection level: Choose a gland with the appropriate IP rating (Ingress Protection) based on the required level of protection.
              • Standards: Ensure the gland complies with relevant industry standards, such as IEC or UL
              Question: What are the benefits of using cable glands?
              Answer: Using cable glands offers several benefits, including:
              • Protection: Cable glands protect cables from moisture, dust, and other environmental factors.
              • Safety: They help prevent electrical hazards by ensuring proper grounding and insulation.
              • Durability: Cable glands are designed to be durable and long-lasting.
              • Compliance: They can help ensure compliance with various safety standards and regulations.
              Question: What certifications should one look for when buying cable glands?
              Answer: Look for industry certifications that match your specific application needs:
              • ATEX (for explosive atmospheres)
              • IECEx (international certification for hazardous areas)
              • UL (safety standards, especially in North America)
              • CSA (Canadian Standards Association for North America)
              • RoHS (restriction of hazardous substances in electrical equipment) These certifications ensure the cable glands meet strict safety and quality requirements.
              Question: What are some common mistakes to avoid when installing cable glands?
              Answer: Here are some common mistakes to avoid:
              • Overtightening: Overtightening the gland nut can damage the cable or the gland itself.
              • Incorrect cable preparation: The cable should be prepared correctly before insertion into the gland.
              • Using the wrong gland type: Ensure that the gland is compatible with the cable type and the operating environment.
              • Neglecting maintenance: Regular inspections and maintenance are essential to prevent problems and ensure the gland's effectiveness.
              Question: What does 'ex d' and 'ex e' mean in cable glands?
              Answer: Ex d (Flameproof Enclosure): Refers to a gland that can withstand an internal explosion without allowing flames or heat to escape.
              Ex e (Increased Safety): Designed for environments where no arcs or sparks are likely to be produced, offering increased protection through superior sealing and insulation.
              These classifications are part of the IECEx and ATEX standards for hazardous environments.
              X