A transformer is a device that changes the voltage, also called a power transformer. Performs the step-down and step-up of AC voltage, and makes adjustments necessary for use in electronic devices. The transformer has a structure in which a primary coil and a secondary coil are wound around an iron core. Depending on the position of the iron core and the coil, it is divided into an inner iron type where the coil covers the iron core and an outer iron type where the iron core is outside the coil. Wiring methods are classified into two types: single-phase, which is a 100 V power supply used in offices, and three-phase, which is a 200 V power supply that sends a large amount of power. The winding of the coil is usually compound wound in which the primary and secondary sides are insulated, but there are also smaller auto transformers. There are also types that can be connected with the cover attached, types that can be used overseas and in Japan, portable types that are suitable for on-site construction with different power and voltage, etc.
CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 12 Day(s) or Less
  • 13 Day(s) or Less
  • 15 Day(s) or Less
  • Others

3 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    MOUSE Series, Transformer For Use Overseas

    MOUSE Series, Transformer For Use Overseas

    SWALLOW ELECTRIC

    MOUSE series, lightest travel transformer. With weight of 290 g, it can easily charge by game machine or mobile while transporting.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    AC110 to 130 0.06 AC100 Single-phase/single-winding - - 39 NA Available 77 54
    From: ₹ 3,091.27
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Power Transformer For Use Overseas, PAL-A Series

    Power Transformer For Use Overseas, PAL-A Series

    SWALLOW ELECTRIC

    PAL-E series, transformers made 100V electronics can be used in different countries of 110 to 130V during travel.

    CAD :
    2D
    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    AC110 to 130 0.35 ~ 0.5 AC100 Single-phase/single-winding - - 150 NA Available 110 140
    From: ₹ 11,032.56
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    PAL-AP Series

    PAL-AP Series

    SWALLOW ELECTRIC

    PAL-AP series, transformers made 100V electronics can be used in different countries of 110 to 130V during travel.

    CAD :
    2D
    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    AC110 to 130 1 ~ 1.5 AC100 Single-phase/single-winding - - 195 NA Available 130 135
    From: ₹ 14,709.22
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
CAD
From
Days to Ship
Primary voltage(V)
Capacity(kVA)
Secondary voltage(V)
Number of phases/winding
Insulation type
Input/output terminal shape
Dimension vertical(mm)
Shield presence
With/without Case
Dimension width(mm)
Dimension depth(mm)

    You can add up to 6 items per a category to the compare list.

    MOUSE Series, Transformer For Use Overseas

        You can add up to 6 items per a category to the compare list.

        Power Transformer For Use Overseas, PAL-A Series

            You can add up to 6 items per a category to the compare list.

            PAL-AP Series
              Brand

              SWALLOW ELECTRIC

              SWALLOW ELECTRIC

              SWALLOW ELECTRIC

              Product Series

              MOUSE Series, Transformer For Use Overseas

              Power Transformer For Use Overseas, PAL-A Series

              PAL-AP Series

              CAD
              • 2D
              • 2D
              From

              ₹ 3,091.27

              ₹ 11,032.56

              ₹ 14,709.22

              Days to Ship 5 Day(s) or more 5 Day(s) or more 5 Day(s) or more
              Primary voltage(V)AC110 to 130AC110 to 130AC110 to 130
              Capacity(kVA)0.060.35 ~ 0.51 ~ 1.5
              Secondary voltage(V)AC100AC100AC100
              Number of phases/windingSingle-phase/single-windingSingle-phase/single-windingSingle-phase/single-winding
              Insulation type---
              Input/output terminal shape---
              Dimension vertical(mm)39150195
              Shield presenceNANANA
              With/without CaseAvailableAvailableAvailable
              Dimension width(mm)77110130
              Dimension depth(mm)54140135

              Loading...

              1. 1

              Related Categories to Transformers

              FAQ Transformers

              Question: What is the difference between 1 phase transformers and 3 phase transformers.
              Answer: 1. In a single-phase transformer, the electricity is supplied through two wires called Line and neutral. In three phase transformers, the electricity is supplied through three wires (four wires if neutral wire is included).
              2. The voltage of single-phase transformer supply is 230V whereas three-phase transformer supply is 415V.
              3. The efficiency of a three-phase transformer is significantly higher than a single-phase supply and the power transfer capability is also more.
              Question: How many types of transformers?
              Answer: Type of transformer can be separated by different types of applications.
              1. Transformer types based on core structure.
                 1.1) Iron core transformer
                 1.2) Shell core transformer
                 1.3) H-type core transformer
              2. Transformer types based on electric system.
                 2.1) Single-phase transformer
                 2.2) Three-phase transformer
              3. Transformer types based on voltage level.
                 3.1) Step-up transformer which is use for boost voltage up then transmit to secondary side.
                 3.2) Step-down transformer which is use for reducing voltage down then transmit to secondary side.
                 3.3) Isolation transformer which voltage at primary and secondary side are same. Typically, applicable for Laboratory which is need stable voltage and current.
              Question: What is transformer maintenance method?
              Answer: 1. Should install and using in low-humidity to prevent short circuit issue.
              2. Installation place should be good for heat transfer.
              3. Always keep cleaning heat transfer component.
              4. Always keep inspection terminal and wire.
              Question: Why transformer is necessary?
              Answer: Transformers is necessary because each electric device need different level of voltage. So, we must use transformer to adjust the electrical voltage from power source to sub-unit. Such as, reduce voltage from high-power electric post to the building and transformer for reduce voltage level from electric source of building to each electrical home appliance as well.
              X