  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Transformers(Number of phases/winding:Other)

A transformer is a device that changes the voltage, also called a power transformer. Performs the step-down and step-up of AC voltage, and makes adjustments necessary for use in electronic devices. The transformer has a structure in which a primary coil and a secondary coil are wound around an iron core. Depending on the position of the iron core and the coil, it is divided into an inner iron type where the coil covers the iron core and an outer iron type where the iron core is outside the coil. Wiring methods are classified into two types: single-phase, which is a 100 V power supply used in offices, and three-phase, which is a 200 V power supply that sends a large amount of power. The winding of the coil is usually compound wound in which the primary and secondary sides are insulated, but there are also smaller auto transformers. There are also types that can be connected with the cover attached, types that can be used overseas and in Japan, portable types that are suitable for on-site construction with different power and voltage, etc.
CAD
Days to Ship
  • All
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 12 Day(s) or Less
  • 13 Day(s) or Less
  • 15 Day(s) or Less
  • Others

4 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    WORLD Series, Transformer For Use Overseas

    WORLD Series, Transformer For Use Overseas

    SWALLOW ELECTRIC

    WORLD series, with manual input voltage changer. Can be used in different countries by capacity of input voltage in range of 110 to 240V.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    AC110 to 240 0.12 ~ 0.3 AC100 Other - - 50 ~ 120 NA Available 82 ~ 155 46 ~ 128
    From: ₹ 14,669.44
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Transformer AVR-E Series, AC Constant Voltage Power Supply Unit

    Transformer AVR-E Series, AC Constant Voltage Power Supply Unit

    SWALLOW ELECTRIC

    AVR-E series, product with auto-shift in range of 170 to 260V for Japanese electronic products. Most suitable product for unstable voltage places.

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    AC170 to 260 1.5 ~ 2 AC100 Other - - 235 ~ 300 NA Available 145 ~ 210 150 ~ 250
    From: ₹ 43,802.45
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    S Series

    S Series

    AIHARA

    Reference color transformer case of indoor standard:Munsell color system 5Y7/S series of 1 (semigloss)

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    - 0.05 - Other - - 113 - NA 120 170
    From: ₹ 6,696.47
    Days to Ship: 13 Day(s) or more
    day to ship 13 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Single-Phase/Three-Phase Transformer Case, BK Series

    Single-Phase/Three-Phase Transformer Case, BK Series

    SWALLOW ELECTRIC

    BK series. Indoor transformer case. (Paint color· Munsell color system 5Y7/1)

    Primary voltage(V) Capacity(kVA) Secondary voltage(V) Number of phases/winding Insulation type Input/output terminal shape Dimension vertical(mm) Shield presence With/without Case Dimension width(mm) Dimension depth(mm)
    - 0.5 or Less ~ 50 - Other - - 135 ~ 550 - Available 180 ~ 410 150 ~ 500
    From: ₹ 6,026.45
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
From
Days to Ship
Primary voltage(V)
Capacity(kVA)
Secondary voltage(V)
Number of phases/winding
Insulation type
Input/output terminal shape
Dimension vertical(mm)
Shield presence
With/without Case
Dimension width(mm)
Dimension depth(mm)

    You can add up to 6 items per a category to the compare list.

    WORLD Series, Transformer For Use Overseas

        You can add up to 6 items per a category to the compare list.

        Transformer AVR-E Series, AC Constant Voltage Power Supply Unit

            You can add up to 6 items per a category to the compare list.

            S Series

                You can add up to 6 items per a category to the compare list.

                Single-Phase/Three-Phase Transformer Case, BK Series
                  Brand

                  SWALLOW ELECTRIC

                  SWALLOW ELECTRIC

                  AIHARA

                  SWALLOW ELECTRIC

                  Product Series

                  WORLD Series, Transformer For Use Overseas

                  Transformer AVR-E Series, AC Constant Voltage Power Supply Unit

                  S Series

                  Single-Phase/Three-Phase Transformer Case, BK Series

                  From

                  ₹ 14,669.44

                  ₹ 43,802.45

                  ₹ 6,696.47

                  ₹ 6,026.45

                  Days to Ship 5 Day(s) or more 5 Day(s) or more 13 Day(s) or more 5 Day(s) or more
                  Primary voltage(V)AC110 to 240AC170 to 260--
                  Capacity(kVA)0.12 ~ 0.31.5 ~ 20.050.5 or Less ~ 50
                  Secondary voltage(V)AC100AC100--
                  Number of phases/windingOtherOtherOtherOther
                  Insulation type----
                  Input/output terminal shape----
                  Dimension vertical(mm)50 ~ 120235 ~ 300113135 ~ 550
                  Shield presenceNANA--
                  With/without CaseAvailableAvailableNAAvailable
                  Dimension width(mm)82 ~ 155145 ~ 210120180 ~ 410
                  Dimension depth(mm)46 ~ 128150 ~ 250170150 ~ 500

                  Loading...

                  1. 1

                  Related Categories to Transformers

                  FAQ Transformers

                  Question: What is the difference between 1 phase transformers and 3 phase transformers.
                  Answer: 1. In a single-phase transformer, the electricity is supplied through two wires called Line and neutral. In three phase transformers, the electricity is supplied through three wires (four wires if neutral wire is included).
                  2. The voltage of single-phase transformer supply is 230V whereas three-phase transformer supply is 415V.
                  3. The efficiency of a three-phase transformer is significantly higher than a single-phase supply and the power transfer capability is also more.
                  Question: How many types of transformers?
                  Answer: Type of transformer can be separated by different types of applications.
                  1. Transformer types based on core structure.
                     1.1) Iron core transformer
                     1.2) Shell core transformer
                     1.3) H-type core transformer
                  2. Transformer types based on electric system.
                     2.1) Single-phase transformer
                     2.2) Three-phase transformer
                  3. Transformer types based on voltage level.
                     3.1) Step-up transformer which is use for boost voltage up then transmit to secondary side.
                     3.2) Step-down transformer which is use for reducing voltage down then transmit to secondary side.
                     3.3) Isolation transformer which voltage at primary and secondary side are same. Typically, applicable for Laboratory which is need stable voltage and current.
                  Question: What is transformer maintenance method?
                  Answer: 1. Should install and using in low-humidity to prevent short circuit issue.
                  2. Installation place should be good for heat transfer.
                  3. Always keep cleaning heat transfer component.
                  4. Always keep inspection terminal and wire.
                  Question: Why transformer is necessary?
                  Answer: Transformers is necessary because each electric device need different level of voltage. So, we must use transformer to adjust the electrical voltage from power source to sub-unit. Such as, reduce voltage from high-power electric post to the building and transformer for reduce voltage level from electric source of building to each electrical home appliance as well.
                  X