OTOWA
A compact type with a built-in detachment device and deterioration indicator
[Features]
· Includes a built-in detachment device. Includes a deterioration indicator.
· The built-in detachment mechanism prevents the SPD from smoking and/or igniting in cases where the ZnO element deteriorates.
· With function for indicating detachment mechanism operation.
· Compact, enables space-saving.
· Combined type between wires and ground protecting from lightning-induced surges.
· Use of multi‐terminal components helped in making the smallest product in the industry. Same dimensions are available for 200V to 500V.
· Safe lightning surge bearing strength.
· Using maximum discharge current 5kA (8 / 20 μs), it is difficult to break even with a large lightning surge.
· A long service life type that stands up to repeated lightning surges of 1000A500 times.
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC200V / AC400V / AC500V | Integrated | Other | Class II | UL / CUL / TUV / CSA | 33.5 | 38 | 28 |
From: ₹ 3,757.18 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
MISUMI
Built-in disconnection mechanism / degradation display included. JIS C 5381-1 Category II Compliant
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V | Integrated | - | Class II | UL / CUL / TUV / CSA | 33.5 | 38 | 28 |
From: ₹ 3,658.29 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
For Low Voltage Power Supplies (100/200 VAC)
MISUMI
High-performance model no follow current and excellent responsiveness. Category II / III (JIS C5381-1) for Low Voltages
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V | Single pole type | - | Class II / Class III | - | 96 | 25 | 61.5 |
From: ₹ 6,174.73 |
---|
Days to Ship: 6 Day(s) or more |
You can add up to 6 items per a category to the compare list.
SPD Class II for distribution boards
OTOWA
SPD for power distribution board with built-in automatic disconnection device.
[Features]
・ JIS agreement type circuit breaker for wiring with 2-pole dimension width of 50 mm, easy to install in the panel
・ Built-in automatic disconnection device, SPD function display, deteriorated contact output compatible (S Type only), and a safety function even when it deteriorates
・ Excellent responsiveness, no follow current
・ With electric shock prevention terminal cover
・ 3 patterns for mounting (DIN rail / connecting mounting plate / screw mount with mounting bracket)
[Applications]
・ Protects various low voltage power supply circuits from lightning surges
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V / AC200V / AC400V | Integrated | Crimp terminal attached | Class II | - | 107 | 50 | 65 |
From: ₹ 12,463.47 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
SPD Class Ⅱ with Agreed Dimensions
OTOWA
SPD that supports Class II (JIS C5381-11) and protects wire-to-wire and wire-to-ground with 1 unit.
[Features]
・ Compliant with JIS agreement type circuit breaker dimensions (for 3 poles)
・ Copper strips for Branch MCCB are also available for easy installation inside the panel
・ Built-in automatic disconnection device, SPD function display, deteriorated contact output compatible (S Type only), and a safety function even when it deteriorates
・ Excellent responsiveness, no follow current
・ With electric shock prevention terminal cover
・ 4 patterns for mounting (DIN rail / M4 screw / connecting mounting plate / screw mount with mounting bracket)
[Applications]
・ Protects various low voltage power supply circuits from lightning surges
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V / AC200V / AC400V | Integrated | Crimp terminal attached | Class II | - | 104.5 | 75 | 65 |
From: ₹ 11,492.62 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Special for photovoltaic systems, Power supply SPD, Class II and III
OTOWA
Solar-system-only, more efficient and compact
[Features]
· More efficient and compact.
· By combining each SPD, less man hours are required for wiring thereby reducing the work time considerably.
· Plug in type.
· Only the main SPD unit can be replaced.
· Safe even during deterioration.
· Includes a built-in detachment device in case of deterioration.
· Includes SPD operation display functionality.
· Normally: Blue, when it deteriorates: Red.
· Deteriorated contact output support.
· C contact point (contact points a and b).
· Excellent response speed, high performance, non-dynamic current.
· Response speed: 3nsec or less.
· Imax: 40kA.
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | DC600V or higher | Single pole type | Crimp terminal attached | Class II / Class III | - | 95 | 18.5 ~ 36.5 | 63.5 |
From: ₹ 9,030.07 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
Power Supply SPD, Class II/III, LGL Series
OTOWA
SPD for power supply with built-in disconnection device with no follow current and excellent response performance.
[Features]
・ Response speed is 3 nsec or less, excellent response, no follow current
・ Maximum electric discharge machining current (Imax) protects the power supply from 20 kA, 40 kA (8/20 μs), lightning surge/ switching surge, multiple-lightning
・ With safety function even when it deteriorates
・ Built-in disconnecting device, visual inspection from transparent inspection window
・ DIN rail mounting, screw mounting supported
・ Easy and reliable inspection and attachment/detachment mechanism
・ Circuit insulation resistance measurement (insulation resistance test) available
・ Can be used for connection between ground electrodes
[Applications]
・ Protection of low-voltage distribution board (power distribution board) and low-voltage power supply circuit
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V / AC200V / AC400V | Single pole type | Crimp terminal attached | Class II / Class III | - | 96 | 25 | 61.5 ~ 70 |
From: ₹ 6,178.75 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
OTOWA
SPD (arrestor) with arrestor function display for easy inspection.
[Features]
・ Same dimensions as the safety breaker
・ Can be mounted on power distribution board in an empty space for 1 safety breaker
・ Easy to install
・ One unit can protect wire-to-wire and wire-to-ground of single-phase 3-wire circuits, and save space
・ Easy inspection with arrestor function display
[Applications]
・ Protects the power supply system of general households from lightning surges
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V / AC200V | Integrated | Crimp terminal attached | - | - | 70 | 32 | 38 |
From: ₹ 6,168.49 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
SPD SG-ZJ Series for Control Power Circuit
OTOWA
Categories C2 and D1 compliant plug in type for power control circuits
[Features] Compatible to
· IEC categories C2 and D1.
· C2: 8/ 20 μ s10kA, D1: 10 / 350 μ s3kA (C2: positive and negative 5 times each, total 10 times, D1: positive and negative 1 time each, total 2 times)
· DIN rail compatible.
· Plug in type (easy to check and replace)
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | DC24V | Single pole type | Crimp terminal attached | IEC category C2 / IEC category D1 | - | 72.5 | 32.4 | 69 |
From: ₹ 8,918.73 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
SPD for Power Supply Class I/II for Solar System
OTOWA
Solar system only with tremendous protection abilities
[Features]
· Tremendous protection abilities.
· Impulse current Iimp25kA, protects facilities and devices from harm caused by direct lightning strikes.
· Voltage protection level is less than 2500V.
· Non-dynamic current and excellent responsiveness.
· Response speed is less than :3nsec.
· Passed the 10 / 350 Μs wave class test.
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | DC600V or higher | Single pole type | Crimp terminal attached | Class I / Class II | - | 102 | 33 | 122.5 |
From: ₹ 49,452.87 |
---|
Days to Ship: 12 Day(s) or more |
You can add up to 6 items per a category to the compare list.
SPD for Direct Lightning Class I/II
OTOWA
Tremendous protection ability for non-dynamic current and excellent responsiveness
[Features]
· Tremendous protection ability.
· Impulse current Iimp25kA, protects facilities and devices from harm caused by direct lightning strikes.
· Voltage protection level is less than 1300V (LD-22EFS).
· Non-dynamic current and excellent responsiveness.
· Response speed is less than :3nsec (LD-22EFSLD-42EFS). Passed 10 / 350 Μs wave class test. It can be used to connect between earth and electrodes.
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC500V | Single pole type | Crimp terminal attached | Class I / Class II | - | 102 | 33 | 122.5 |
From: ₹ 49,452.87 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
OTOWA
[Features]
・ Compact, 1 unit protects wire-to-wire and wine-to-ground of a single-phase 2-wire circuit
・ Maximum electric discharge machining current (Imax) is 10 kA (8/20 μs). Protects the power supply from lightning surges and switching surges
・ Excellent responsiveness, no follow current
・ Built-in automatic disconnection device
・ With operation display lamp
・ With safety function even when it deteriorates
[Applications]
・ Industrial equipment, communication equipment, fire alarms, low-voltage distribution boards, control panels, water facilities, and other electric/electronic equipment
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V / AC200V | Integrated | Crimp terminal attached | Class II | - | 64 | 20 | 63 |
From: ₹ 6,711.40 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
SPD for Power Supply Class II/III LS Series
OTOWA
Lightning arrester that protects various low-voltage power supply circuits from lightning surges and is compatible with Class II/III (JIS C5381-11).
[Features]
・ By integrating each SPD, the wiring labor-hours can be reduced and the work time can be greatly reduced
・ Plug-in type, SPD body can be replaced independently
・ Built-in disconnection device for deterioration
・ With SPD operation display function. Supports deteriorated contact output for peace of mind even when deteriorated
[Applications]
・ Power supply protection for factories, buildings, etc.
・ Power supply protection for computers and electronic devices
・ Fire alarm power supply protection
・ Power supply protection for other low-voltage equipment
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | AC100V / AC200V / AC400V | Single pole type / Integrated | Crimp terminal attached | Class II / Class III | - | 95 | 18.5 ~ 72.5 | 63.5 |
From: ₹ 6,182.53 |
---|
Days to Ship: 5 Day(s) or more |
You can add up to 6 items per a category to the compare list.
OMRON
Protects the 61F body from lightning
[Features]
·A high-capacity protective device intended to protect against induced lightning damage.
·It is used in conditions that are susceptible to induction failure, such as elevated water tanks and mountainous areas.
Application | Voltage | Type | Mounting Method | Class, category | Representative Standard | Dimension vertical(mm) | Dimension width(mm) | Dimension depth(mm) |
---|---|---|---|---|---|---|---|---|
For Power Supply | - | Other | Other | - | - | 51.5 | 34 | 34 |
From: ₹ 4,406.24 |
---|
Days to Ship: 5 Day(s) |
Brand |
---|
Product Series |
CAD |
From |
Days to Ship |
Application |
Voltage |
Type |
Mounting Method |
Class, category |
Representative Standard |
Dimension vertical(mm) |
Dimension width(mm) |
Dimension depth(mm) |
You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | You can add up to 6 items per a category to the compare list. | |
Brand | OTOWA | MISUMI | MISUMI | OTOWA | OTOWA | OTOWA | OTOWA | OTOWA | OTOWA | OTOWA | OTOWA | OTOWA | OTOWA | OMRON |
Product Series | Special for photovoltaic systems, Power supply SPD, Class II and III | |||||||||||||
CAD |
|
|
|
|
|
|
| |||||||
From | ₹ 3,757.18 | ₹ 3,658.29 | ₹ 6,174.73 | ₹ 12,463.47 | ₹ 11,492.62 | ₹ 9,030.07 | ₹ 6,178.75 | ₹ 6,168.49 | ₹ 8,918.73 | ₹ 49,452.87 | ₹ 49,452.87 | ₹ 6,711.40 | ₹ 6,182.53 | ₹ 4,406.24 |
Days to Ship | 5 Day(s) or more | 6 Day(s) or more | 6 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 12 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) |
Application | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply | For Power Supply |
Voltage | AC200V / AC400V / AC500V | AC100V | AC100V | AC100V / AC200V / AC400V | AC100V / AC200V / AC400V | DC600V or higher | AC100V / AC200V / AC400V | AC100V / AC200V | DC24V | DC600V or higher | AC500V | AC100V / AC200V | AC100V / AC200V / AC400V | - |
Type | Integrated | Integrated | Single pole type | Integrated | Integrated | Single pole type | Single pole type | Integrated | Single pole type | Single pole type | Single pole type | Integrated | Single pole type / Integrated | Other |
Mounting Method | Other | - | - | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Crimp terminal attached | Other |
Class, category | Class II | Class II | Class II / Class III | Class II | Class II | Class II / Class III | Class II / Class III | - | IEC category C2 / IEC category D1 | Class I / Class II | Class I / Class II | Class II | Class II / Class III | - |
Representative Standard | UL / CUL / TUV / CSA | UL / CUL / TUV / CSA | - | - | - | - | - | - | - | - | - | - | - | - |
Dimension vertical(mm) | 33.5 | 33.5 | 96 | 107 | 104.5 | 95 | 96 | 70 | 72.5 | 102 | 102 | 64 | 95 | 51.5 |
Dimension width(mm) | 38 | 38 | 25 | 50 | 75 | 18.5 ~ 36.5 | 25 | 32 | 32.4 | 33 | 33 | 20 | 18.5 ~ 72.5 | 34 |
Dimension depth(mm) | 28 | 28 | 61.5 | 65 | 65 | 63.5 | 61.5 ~ 70 | 38 | 69 | 122.5 | 122.5 | 63 | 63.5 | 34 |
Loading...
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy