  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Circuit Breakers (Low Capacity)(Ampere frame:30AF or less)

Circuit Breakers (Low Capacity) products in the Electrical & Controls category. Specified by Ampere frame 30AF or less. There are around 2 items of Circuit Breakers (Low Capacity) products available and the specifications can easily be compared. Parts and equipment for controlling machines and electrical systems. Controllers and power supplies Circuit Breakers (Low Capacity) offers a wide selection of products, on time delivery, free shipping and no minimum order quantity with a consulting team available.
CAD
Days to Ship
  • All
  • 5 Day(s) or Less

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    ABS series (distribution panel-type, no fuse) [ABS32FB]

    ABS series (distribution panel-type, no fuse) [ABS32FB]

    LSIS

    [Features]
    · No fuse breaker for distribution boards that is compact and space-saving.
    · The distribution board type is compact and can be used for distribution boards.
    · Substantial lineup of rated current from 3A to 100A.
    · Height 96 mm, depth 60 mm, JIS agreement size.
    · Easy attachment of auxiliary equipment.
    · Passed testing, CE mark certified product.
    · Types with a breaking capacity of 5kA or 10kA are available.
    · 400V power supplies can also be used.

    Ampere frame Rated block capacity AC 200 V(kA) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current(A) Mounting Method Connection Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm)
    30AF or less 5 Available 2 / 3 3 ~ 30 DIN/Screw retention Surface type PSE / CE 96 50 ~ 75 80
    From: ₹ 1,429.18
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    Circuit Breaker BS series

    Circuit Breaker BS series

    SETTSUMETAL

    [Features]
    · Breaker that can be used with AC power ducting, etc.
    [Specifications]
    · Connectable electric wires: 5.5 to 8 mm. When using stranded wire (1.25 to 3.5 mm) such as ø1.6 to 2.6 device wire, use a bar crimp terminal.

    Ampere frame Rated block capacity AC 200 V(kA) Rated block capacity, voltages except VAC 100/200/400, VDC 250 Number of Poles Rated Current(A) Mounting Method Connection Method Representative Standard Dimension height(mm) Dimension width(mm) Dimension depth(mm)
    30AF or less - Available 2 20 Fasten With Screws Surface type PSE 70 32 55.5
    From: ₹ 1,161.24
    Days to Ship: 5 Day(s) or more
    day to ship 5 Day(s) or more
Brand
Product Series
From
Days to Ship
Ampere frame
Rated block capacity AC 200 V(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Number of Poles
Rated Current(A)
Mounting Method
Connection Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)

    You can add up to 6 items per a category to the compare list.

    ABS series (distribution panel-type, no fuse) [ABS32FB]

        You can add up to 6 items per a category to the compare list.

        Circuit Breaker BS series
          Brand

          LSIS

          SETTSUMETAL

          Product Series

          ABS series (distribution panel-type, no fuse) [ABS32FB]

          Circuit Breaker BS series

          From

          ₹ 1,429.18

          ₹ 1,161.24

          Days to Ship 5 Day(s) or more 5 Day(s) or more
          Ampere frame30AF or less30AF or less
          Rated block capacity AC 200 V(kA)5-
          Rated block capacity, voltages except VAC 100/200/400, VDC 250AvailableAvailable
          Number of Poles2 / 32
          Rated Current(A)3 ~ 3020
          Mounting MethodDIN/Screw retentionFasten With Screws
          Connection MethodSurface typeSurface type
          Representative StandardPSE / CEPSE
          Dimension height(mm)9670
          Dimension width(mm)50 ~ 7532
          Dimension depth(mm)8055.5

          Loading...

          1. 1

          Related Categories to Circuit Breakers (Low Capacity)

          FAQ Circuit Breakers (Low Capacity)

          Question: Types of circuit breaker and their applications.
          Answer: Circuit breakers mainly are categorized based on application as per voltage.
          1. Low Voltage Circuit Breaker
          Low-voltage circuit breakers are typically used in applications such as lighting circuits, motor control centers, feeder circuits, and any application in which electrical power needs to be turned on and off and overcurrent protection is required.
          2. Medium Voltage Circuit Breakers
          Medium voltage breakers are designed to be operated electrically by a closing solenoid or a stored energy mechanism. Manual operation is used primarily for breaker maintenance.
          3. HIGH-VOLTAGE CIRCUIT BREAKERS
          High-voltage circuit breakers are mechanical switching devices that connect and break current circuits (operating currents and fault currents) and carry the nominal current in the closed position.
          Question: What can cause the main circuit breaker to trip?
          Answer: The most common cause of a tripped circuit breaker is an overload in that circuit. Each circuit is only intended to carry a certain electrical load, and if it exceeds this load, it will cause the breaker to trip. This is important, as overloading a circuit can cause the wiring to heat up and potentially create a fire risk. In fact, it is this excess heat running through the circuit that causes the breaker to trip.
          Question: How we know that have to replace breaker?
          Answer: 1. Breaker trips frequently.
          2. Burning smell coming from the electrical panel.
          3. Poorly performing appliances and light fixtures.
          4. Breaker fails to stay in reset mode.
          5. Visible signs of physical damage.
          Question: How do I know whether to get a 15 or 20 A circuit breaker?
          Answer: Calculate the total current of all electrical equipment. that want to be connected to the breaker The sum of the calculated current should not exceed 80% of the breaker capacity. For example, a 15 A breaker can be connected to external devices up to 12A (15 x 0.80 = 12), and a 20 A breaker can be connected to external devices up to 16A (20 x 0.80 = 16). This can lead to calculation errors and can cause a fire.