PLC (Wire-Saving Dedicated Units)(Mounting Method:Screw mount)

PLC (wire saving dedicated units) are units where connector terminal block conversion units are used for the connections with the PLC, which has many signals, in order to save wiring work and space. Many types are available, including those equipped with smart slave common functions and those where all wiring is performed with a single connector cable. Other types include low-profile waterproof types and spring clamp terminal block types, which can be used for connecting field network devices. PLC (wire saving dedicated units) include types that are very easy to mount without needing tools or soldering, but are still highly noise-resistant and reliable, and types that can be equipped with expansion units. Select according to the operating environment or application.
CAD
Days to Ship
  • All
  • Same day
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less

2 items

Sort By
30
45
60
  1. 1
  • You can add up to 6 items per a category to the compare list.

    DRT2 board terminal

    DRT2 board terminal

    OMRON

    Smart slave, board-type PLC (dedicated wiring-saving unit).
    [Features]
    ·It can easily support various I/O interfaces and realizes reduced wiring.
    ·The DRT2-□D32BV (-1) type can be easily attached to a printed circuit board created by the user with screws.
    ·I/O terminal: MIL connector type.
    ·Internal circuit power supply rated voltage: Supplied from communication connector.
    ·Rated voltage of I/O power supply: 24 V DC.

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Slave station DeviceNet Input/Output / Communication Function Terminal Block Screw mount CE / UL / CUL / CSA
    From: ₹ 35,357.00
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
  • You can add up to 6 items per a category to the compare list.

    DRT2 environmental terminal

    DRT2 environmental terminal

    OMRON

    A lineup of remote I/O terminals with high environmental resistance (IP67) and mixed input, output, and input/output types with an emphasis on economy.
    [Features]
    ・ Abnormal diagnosis such as sensor power supply short circuit detection is also possible
    ・ Equipped with a common function for smart slaves, it strongly supports monitoring of the operating status of the device and effective maintenance
    ・ Achieves high environmental resistance dust-proof and drip-proof (IP67)
    ・ For input/output. PNP compatible (input (-) common / output (+) common). 8 points for input / 8 points for output
    ・ I/O connection form: Sensor I/O connector
    ・ Internal circuit power supply rated voltage: Supplied from communication connector
    ・ Rated voltage of I/O power supply: DC24V

    Type Control Type Network Varieties Additional Function Connection Terminal Mounting Method Representative Standard
    Slave station DeviceNet Input/Output / Communication Function Connector Screw mount CE / UL / CUL / CSA
    From: ₹ 45,703.00
    Days to Ship: 6 Day(s) or more
    day to ship 6 Day(s) or more
Brand
Product Series
From
Days to Ship
Type
Control Type Network Varieties
Additional Function
Connection Terminal
Mounting Method
Representative Standard

    You can add up to 6 items per a category to the compare list.

    DRT2 board terminal

        You can add up to 6 items per a category to the compare list.

        DRT2 environmental terminal
          Brand

          OMRON

          OMRON

          Product Series

          DRT2 board terminal

          DRT2 environmental terminal

          From

          ₹ 35,357.00

          ₹ 45,703.00

          Days to Ship 6 Day(s) or more 6 Day(s) or more
          TypeSlave stationSlave station
          Control Type Network VarietiesDeviceNetDeviceNet
          Additional FunctionInput/Output / Communication FunctionInput/Output / Communication Function
          Connection TerminalTerminal BlockConnector
          Mounting MethodScrew mountScrew mount
          Representative StandardCE / UL / CUL / CSACE / UL / CUL / CSA

          Loading...

          1. 1

          Related Categories to PLC (Wire-Saving Dedicated Units)

          FAQ PLC (Wire-Saving Dedicated Units)

          Question: What are the unique features of PLC Wire-Saving Dedicated Units and how do they benefit industrial automation?
          Answer: PLC Wire-Saving Dedicated Units offer streamlined connectivity by reducing the number of wires needed for communication. These units often employ advanced communication protocols and compact designs, minimizing wiring complexity. This not only simplifies installation but also enhances the overall reliability of the industrial automation system.
          Question: How do Digital and Analog I/O Units integrate with PLC Wire-Saving systems?
          Answer: Digital and Analog I/O Units seamlessly integrate with PLC Wire-Saving systems by connecting through a simplified wiring scheme. Digital I/O handles discrete signals, while Analog I/O manages continuous signals. Both types contribute to efficient data exchange between the PLC and various devices in the automation setup, supporting precise control and monitoring.
          Question: What are the mounting and installation methods available for PLC Wire-Saving Dedicated Units?
          Answer: PLC Wire-Saving Dedicated Units offer versatile mounting options, including DIN rail mounting for easy integration into control panels. Some units also support direct mounting on machines or equipment, providing flexibility in installation. This adaptability simplifies the deployment of these units in diverse industrial settings.
          Question: What are the key considerations when selecting Analog I/O units for PLC systems?
          Answer: When selecting Analog I/O units for PLC systems, key considerations include the required resolution, speed, and accuracy of the analog signals. Engineers should also evaluate compatibility with the PLC model, signal types supported (e.g., voltage or current), and the specific needs of the application. Additionally, considering factors like environmental conditions and electromagnetic interference ensures optimal performance in industrial settings.