(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Tel: 0124-4688 800Email: cs@misumi.co.in9:00am - 5:30pm (Monday to Saturday)
Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 6:30 24/11/2024 to 4:30 (IST) 25/11/2024. We apologize for the inconvenience.
Please note that the MISUMI Pune office and warehouse will be closed on November 20th due to the state election.
Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.
PLC (wire saving dedicated units) are units where connector terminal block conversion units are used for the connections with the PLC, which has many signals, in order to save wiring work and space. Many types are available, including those equipped with smart slave common functions and those where all wiring is performed with a single connector cable. Other types include low-profile waterproof types and spring clamp terminal block types, which can be used for connecting field network devices. PLC (wire saving dedicated units) include types that are very easy to mount without needing tools or soldering, but are still highly noise-resistant and reliable, and types that can be equipped with expansion units. Select according to the operating environment or application.
Smart slave, board-type PLC (dedicated wiring-saving unit). [Features] ·It can easily support various I/O interfaces and realizes reduced wiring. ·The DRT2-□D32BV (-1) type can be easily attached to a printed circuit board created by the user with screws. ·I/O terminal: MIL connector type. ·Internal circuit power supply rated voltage: Supplied from communication connector. ·Rated voltage of I/O power supply: 24 V DC.
Type
Control Type Network Varieties
Additional Function
Connection Terminal
Mounting Method
Representative Standard
Slave station
DeviceNet
Input/Output / Communication Function
Terminal Block
Screw mount
CE / UL / CUL / CSA
From:
₹ 35,357.00
Days to Ship:
6 Day(s) or more
6 Day(s) or more
You can add up to 6 items per a category to the compare list.
A lineup of remote I/O terminals with high environmental resistance (IP67) and mixed input, output, and input/output types with an emphasis on economy. [Features] ・ Abnormal diagnosis such as sensor power supply short circuit detection is also possible ・ Equipped with a common function for smart slaves, it strongly supports monitoring of the operating status of the device and effective maintenance ・ Achieves high environmental resistance dust-proof and drip-proof (IP67) ・ For input/output. PNP compatible (input (-) common / output (+) common). 8 points for input / 8 points for output ・ I/O connection form: Sensor I/O connector ・ Internal circuit power supply rated voltage: Supplied from communication connector ・ Rated voltage of I/O power supply: DC24V
Type
Control Type Network Varieties
Additional Function
Connection Terminal
Mounting Method
Representative Standard
Slave station
DeviceNet
Input/Output / Communication Function
Connector
Screw mount
CE / UL / CUL / CSA
From:
₹ 45,703.00
Days to Ship:
6 Day(s) or more
6 Day(s) or more
Brand
Product Series
From
Days to Ship
Type
Control Type Network Varieties
Additional Function
Connection Terminal
Mounting Method
Representative Standard
You can add up to 6 items per a category to the compare list.
You can add up to 6 items per a category to the compare list.
Question: What are the unique features of PLC Wire-Saving Dedicated Units and how do they benefit industrial automation?
Answer: PLC Wire-Saving Dedicated Units offer streamlined connectivity by reducing the number of wires needed for communication. These units often employ advanced communication protocols and compact designs, minimizing wiring complexity. This not only simplifies installation but also enhances the overall reliability of the industrial automation system.
Question: How do Digital and Analog I/O Units integrate with PLC Wire-Saving systems?
Answer: Digital and Analog I/O Units seamlessly integrate with PLC Wire-Saving systems by connecting through a simplified wiring scheme. Digital I/O handles discrete signals, while Analog I/O manages continuous signals. Both types contribute to efficient data exchange between the PLC and various devices in the automation setup, supporting precise control and monitoring.
Question: What are the mounting and installation methods available for PLC Wire-Saving Dedicated Units?
Answer: PLC Wire-Saving Dedicated Units offer versatile mounting options, including DIN rail mounting for easy integration into control panels. Some units also support direct mounting on machines or equipment, providing flexibility in installation. This adaptability simplifies the deployment of these units in diverse industrial settings.
Question: What are the key considerations when selecting Analog I/O units for PLC systems?
Answer: When selecting Analog I/O units for PLC systems, key considerations include the required resolution, speed, and accuracy of the analog signals. Engineers should also evaluate compatibility with the PLC model, signal types supported (e.g., voltage or current), and the specific needs of the application. Additionally, considering factors like environmental conditions and electromagnetic interference ensures optimal performance in industrial settings.
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy