AC Input Switching Power Supply (AC-DC Converter), HWS-A Series

Caution
Product Description
HWS-A Series AC Input Switching Power Supply AC-DC Converter.
• Compliant Safety Agency Certifications IEC/EN/UL/CSA60950-1, IEC/EN/UL/CSA62368-1 EN50178-1, UL508 and CE Mark.
• Harmonic Compliance: IEC61000-3-2 Class A.
• EMC Directives: EN55011 / EN55022-B, FCC-B, VCCI-B .
• Input Voltage Range AC (Alternating Current) 85 - 265V. or DC (Direct Current) 120-370V.
• Input Frequency 47 – 63 Hz.
• Output voltage is DC (Direct current), voltages 3 (3.
3V), 5, 12, 15, and 24VDC.
• OPERATING INDICATION: LED (Green color).
• Operating Temperature: -10˚ to +70°C.
• Connectors type Screw terminals.
• Using Cooling method convection.
• Case Material is Aluminum.
HWS-A Series: Single Output Industrial Power Supplies

Product picture of HWS-A Series
Features and Benefits of HWS-A Series
| Features | Benefits |
|---|---|
| • Limited Lifetime Warranty | • Lower Cost of Ownership |
| • High Efficiency (up to 91%) | • Easier System Cooling |
| • Wide Range AC Input | • Supports Global Use |
Specifications of HWS-A Series
| Model | HWS15A/A | HWS30A/A | HWS50A/A | HWS100A/A | HWS150A/A | |
|---|---|---|---|---|---|---|
| Input Voltage Range | - | 85 - 265VAC (47 - 63Hz) Withstands 300VAC for 5s or 120 - 370VDC* | ||||
| Input Current (Typ) (1) | A | 0.35 / 0.2 | 0.65 / 0.4 | 0.65 / 0.35 | 1.3 / 0.65 | 1.9 / 0.95 |
| Inrush Current (1) | A | 14 / 28 | ||||
| Power Factor | - | Meets EN61000-3-2 | ||||
| - | - | 0.97 / 0.91 | 0.98 / 0.93 | 0.98 / 0.93 | ||
| Temperature Coefficient | %/ºC | <0.02%/ºC | ||||
| Overcurrent Protection | % | >105% | ||||
| Overvoltage Protection | V | Yes (see table) | ||||
| Hold Up Time (Typ) | ms | 20 | ||||
| Leakage Current (max) | mA | <0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC) | ||||
| Remote Sense | - | No | Yes | |||
| Indicator | - | Green LED = ON | ||||
| Operating Temperature (with cover) | ºC | -10ºC to +70ºC, derate from 50ºC to 70ºC (2) | ||||
| Storage Temperature | ºC | -30 to +85ºC | ||||
| Humidity (non condensing) | %RH | Operating: 30 - 90%RH, Non operating 10 - 95%RH | ||||
| Cooling | - | Convection | ||||
| Withstand Voltage | VAC | Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. | ||||
| Isolation Resistance | MΩ | >100M at 25ºC & 70%RH, Output to Ground 500VDC | ||||
| Vibration (non operating) | - | 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour | ||||
| Shock | m/s2 | < 196.1 m/s2 | ||||
| Safety Agency Certifications | - | IEC/EN/UL/CSA60950-1, IEC/EN/UL/CSA62368-1 EN50178-1, UL508 and CE Mark | ||||
| Line Dip | - | Complies with SEMI F47 (200VAC line only) | ||||
| Conducted & Radiated EMI | - | EN55011 / EN55022-B, FCC-B, VCCI-B | ||||
| Immunity | - | IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2 | ||||
| Weight (Typ) | g | 190 | 240 | 300 | 470 | 520 |
| Size (HxWxD) (with cover) | mm | 31.5 x 82 x 80 | 31.5 x 82 x 95 | 31.5 x 82 x 120 | 33 x 82 x 160 | 42 x 82 x 160 |
| MTBF (3) | hours | 12,116,851 | 8,169,868 | 3,726,622 | 2,963,512 | 2,676,081 |
| Warranty | - | Limited Lifetime Warranty (See TDK-Lambda's terms and conditions) | ||||
Notes:
* Safety certified for AC input only
(1) 100/200VAC.
(2) Derating varies with model. Please refer to individual model specification for derating graphs.
(3) According to Telcordia document SR-332, issue 3, "Reliability Prediction Procedure for Electronic Equipment"
Conditions: ambient temp. 25deg C, 230Vac input, full load (figures shown for 24V models)
Outline Drawing

Outline drawing of HWS15A/A

Outline drawing of HWS30A/A

Outline drawing of HWS50A/A

Outline drawing of HWS100A/A

Outline drawing of HWS150A/A