(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
Safety relay unit G9SA
[Features]
· Small size, with an abundant series.
· 45 mm width, with an abundant variety of 3-pole. 5-pole, 3-pole + off delay 2-pole, 2 hand controllers.
· We also offer 17.5 mm width 3-pole, off delay 3-pole expansion units.
· Expansion units can be connected with a single action.
· Off delay types can be set at 15 different time levels.
· Certified ENISO13849-1 (PLe/Safety Category 4).
· Can be DIN rail mounted or screw mounted.
Main Contact | Auxiliary Contact | Number of Input Channels | Rated Voltage | Format |
---|---|---|---|---|
3 a | 1 b | 1 ch and 2 ch shared | 24 V AC/DC | Model G9SA-301 |
100 to 240 V AC | ||||
5 a | 24 V AC/DC | Model G9SA-501 | ||
100 to 240 V AC |
Emergency stop unit of Industrial Relays
Main Contact | OFF Delay Contact | Auxiliary Contact | Number of Input Channels | OFF Delay Time | Rated Voltage | Format |
---|---|---|---|---|---|---|
3 a | 2 a | 1 b | 1 ch and 2 ch shared | 7.5 secs | 24 V AC/DC | Model G9SA-321-T075 |
15 secs | 24 V AC/DC | Model G9SA-321-T15 | ||||
30 secs | 24 V AC/DC | Model G9SA-321-T30 |
Emergency stop unit with OFF delay of Industrial Relays
The OFF delay time is variable in 15 steps. The following times can be set:
T075: 0.5/1/1.5/2/2.5/3/3.5/4/4.5/5/5.5/6/6.5/7/7.5 secs
T15: 1/2/3/4/5/6/7/8/9/10/11/12/13/14/15 secs
T30: 2/4/6/8/10/12/14/16/18/20/22/24/26/28/30 secs
Main Contact | Auxiliary Contact | Number of Input Channels | Reset Mode | Input Type | Rated Voltage | Format |
---|---|---|---|---|---|---|
2 a | None | 2 ch | Auto | Inverse | 24 V AC/DC | Model G9SB-2002-A |
1 ch, 2 ch | Positive Common | Model G9SB-200-B | ||||
2 ch | Manual | Inverse | Model G9SB-2002-C | |||
1 ch, 2 ch | Positive Common | Model G9SB-200-D | ||||
3 a | 1 b | No (Power supply directly OFF) | Auto | -- | 24 V DC | Model G9SB-3010 |
2 ch | Inverse | 24 V AC/DC | Model G9SB-3012-A | |||
1 ch, 2 ch | Positive Common | Model G9SB-301-B | ||||
2 ch | Manual | Inverse | Model G9SB-3012-C | |||
1 ch, 2 ch | Positive Common | Model G9SB-301-D |
Format | Model G9SA-301 | Model G9SA-501 | Model G9SA-321-T□ |
---|---|---|---|
Power Supply Voltage | 24 V AC/DC: 24 V AC, 50/60 Hz / 24 V DC, 100 to 240 V AC: 100 to 240 V AC, 50/60 Hz | ||
Allowable Voltage Fluctuation Range | Power supply voltage -15% +10% | ||
Power Consumption | 24 V AC/DC: 1.8 VA/1.7 W max. 100 to 240 V AC: 9 VA max. | 24 V AC/DC: 2.8 VA/2.6 W max. 100 to 240 V AC: 11 VA max. | 24 V AC/DC: 3.5 VA/3.3 W max. 100 to 240 V AC: 12.5 VA max. |
Power supply: G9SA type
Format | Model G9SB-200□-□ | Model G9SB-3010 | Model G9SB-301□-□ |
---|---|---|---|
Power Supply Voltage | 24 V AC/DC: 24 V AC, 50/60 Hz / 24 DC, 24 V DC: 24 V DC | ||
Allowable Voltage Fluctuation Range | Power supply voltage -15% +10% | ||
Power Consumption | 1.6 VA / 1.4 W max. | 1.7 W max. | 2.0 VA / 1.7 W max. |
Power supply: G9SB type
Format | Model G9SA-301/321-T□ | Model G9SA-501 |
---|---|---|
Input Current | 40 mA max. | 60 mA max. |
Input: G9SA type
Format | Model G9SB-200□-□ | Model G9SA-3010 | Model G9SB-301□-□ |
---|---|---|---|
Input Current | 25 mA max. | 60 mA max. | 30 mA max. |
Input: G9SB type
Format | Model G9SA-301/501/321-T□ |
---|---|
Load | Resistive Load |
Rated Load | 250 V AC 5 A, 30 V DC 5 A |
Rated Carry Current | 5 A |
Switch: G9SA type
Format | Model G9SB-200□-□, Model G9SB-3010, Model G9SB-301□-□ |
---|---|
Load | Resistive Load |
Rated Load | 250 V AC 5 A, 30 V DC 5 A |
Rated Carry Current | 5 A |
Switch: G9SB type
Format | Model G9SA-301 | Model G9SA-501/321-T□ | |
---|---|---|---|
Contact Resistance | 100 mΩ | ||
Operating Time | 30 ms max. | ||
Response Time | 10 ms max. | ||
Insulation Resistance | 100 MΩ min., 500 V DC ohmmeter | ||
Dielectric Strength | Between Different Outputs | 2,500 V AC 50/60 Hz 1 min | |
Between Input and Output | |||
Between Power Supply and Output | |||
Between Power Supply and Input (100 to 240 V AC only) | |||
Vibration Resistance | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) | ||
Shock Resistance | Durability | 300 m/s2 | |
Malfunction | 100 m/s2 | ||
Durability | Mechanical | 5,000,000 operations min. (at approx. 7,200 operations/hr) | |
Electrical | 100,000 operations min. (at 1,800 operations/hr under rated load) | ||
Failure Rate (P Level) (Reference Value) | 5 V DC 1 mA | ||
Ambient Operating Temperature | -25 to +55°C (assuming no icing or condensation) | ||
Ambient Operating Humidity | 35 to 85% RH | ||
Terminal Tightening Torque | 0.98 N·m | ||
Weight | Approx. 210 g | Approx. 270 g |
Format | Model G9SB-200□-□ | Model G9SB-3010 | Model G9SB-301□-□ | |
---|---|---|---|---|
Contact Resistance | 100 mΩ | |||
Operating Time | 30 ms max. | |||
Response Time | 10 ms max. | |||
Insulation Resistance | 100 MΩ min., 500 V DC ohmmeter | |||
Dielectric Strength | Between Different Outputs | 2,500 V AC 50/60 Hz 1 min | ||
Between Input and Output | ||||
Between Power Supply and Output | ||||
Vibration Resistance | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) | |||
Shock Resistance | Durability | 300 m/s2 | ||
Malfunction | 100 m/s2 | |||
Durability | Mechanical | 5,000,000 operations min. (at approx. 7,200 operations/hr) | ||
Electrical | 100,000 operations min. (at 1,800 operations/hr under rated load) | |||
Failure Rate (P Level) (Reference Value) | 5 V DC 1 mA | |||
Ambient Operating Temperature | -25 to +55°C (assuming no icing or condensation) | |||
Ambient Operating Humidity | 35 to 85% RH | |||
Terminal Tightening Torque | 0.5 N·m | |||
Weight | Approx. 115 g | Approx. 135 g | Approx. 120 g |
Units: mm
Model G9SA-301
Model G9SA-501
Model G9SA-321-T□ full view
Dimensional outline drawings of Industrial Relays
Units: mm
Model G9SB-200□-□
Model G9SB-3010 full view
Dimensional outline drawings of Industrial Relays
Units: mm
Model G9SB-301□-□ full view
Dimensional outline drawings of Industrial Relays
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Contact Configuration | Representative Standard | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Classification | Off delay time (Second) | Rated Voltage (V) | Reset Mode | Input Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
₹ 22,428.60 | 1 Piece(s) | 5 Day(s) or more | [Other] 3a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit | - | AC100-240 | - | - | ||
₹ 18,324.00 | 1 Piece(s) | Available | 6 Day(s) or more | [Other] 3a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit | - | AC/DC24 | - | - | |
₹ 21,456.00 | 1 Piece(s) | 7 Day(s) or more | [Other] 3a2a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit - With OFF Delay | 7.5 | AC/DC24 | - | - | ||
₹ 31,559.20 | 1 Piece(s) | 5 Day(s) or more | [Other] 3a2a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit - With OFF Delay | 15 | AC/DC24 | - | - | ||
₹ 31,559.20 | 1 Piece(s) | 5 Day(s) or more | [Other] 3a2a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit - With OFF Delay | 30 | AC/DC24 | - | - | ||
₹ 34,771.00 | 1 Piece(s) | 5 Day(s) or more | [Other] 5a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit | - | AC100-240 | - | - | ||
₹ 29,860.00 | 1 Piece(s) | Available | 6 Day(s) or more | [Other] 5a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit | - | AC/DC24 | - | - | |
₹ 32,179.00 | 1 Piece(s) | Available | 7 Day(s) or more | [Other] 5a1b | CE / UL / CCC / CSA | 76 | 45 | 111 | Emergency Stop Unit | - | DC24 | - | - | |
₹ 13,994.69 | 1 Piece(s) | 7 Day(s) or more | 2a | CE / UL / TUV / CCC / CSA | 100 | 18 | 112 | Emergency Stop Unit | - | AC/DC24 | Auto | Inverse | ||
₹ 13,994.69 | 1 Piece(s) | 7 Day(s) or more | 2a | CE / UL / TUV / CCC / CSA | 100 | 18 | 112 | Emergency Stop Unit | - | AC/DC24 | Manual | Inverse | ||
₹ 7,844.00 | 1 Piece(s) | Available | Same day | 2a | CE / UL / TUV / CCC / CSA | 100 | 18 | 112 | Emergency Stop Unit | - | AC/DC24 | Auto | Positive Common | |
₹ 13,994.69 | 1 Piece(s) | 7 Day(s) or more | 2a | CE / UL / TUV / CCC / CSA | 100 | 18 | 112 | Emergency Stop Unit | - | AC/DC24 | Manual | Positive Common | ||
₹ 15,859.13 | 1 Piece(s) | 5 Day(s) or more | [Other] 3a1b | CE / UL / TUV / CCC / CSA | 100 | 18 | 112 | Emergency Stop Unit | - | DC24 | Auto | - | ||
₹ 17,502.16 | 1 Piece(s) | 7 Day(s) or more | [Other] 3a1b | CE / UL / TUV / CCC / CSA | 100 | 23 | 112 | Emergency Stop Unit | - | AC/DC24 | Auto | Inverse | ||
₹ 17,499.89 | 1 Piece(s) | 7 Day(s) or more | [Other] 3a1b | CE / UL / TUV / CCC / CSA | 100 | 23 | 112 | Emergency Stop Unit | - | AC/DC24 | Manual | Inverse | ||
₹ 9,837.00 | 1 Piece(s) | Available | Same day | [Other] 3a1b | CE / UL / TUV / CCC / CSA | 100 | 23 | 112 | Emergency Stop Unit | - | AC/DC24 | Auto | Positive Common | |
₹ 17,499.89 | 1 Piece(s) | 5 Day(s) or more | [Other] 3a1b | CE / UL / TUV / CCC / CSA | 100 | 23 | 112 | Emergency Stop Unit | - | AC/DC24 | Manual | Positive Common |
Loading...
Application | Safety relay | Latch function | NA | Terminal shape | Screw Fastening |
---|