Inverter FREQROL-E700 Series (MRS120W40-3.7K)

Inverter FREQROL-E700 Series (MRS120W40-3.7K)
You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      3,458₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

(i)

Caution

  • This product belongs in RoHS Directive under Category 9 "Monitoring and control equipment" with exclusion from the usage restriction of phthalate esters until 21 July 2021.

Product Description

The E700 Series features excellent drive performance due to advanced magnetic flux vector control and increased short-time overload capacity, dial operation and a built-in USB port for superb operability and expandability

Specifications of braking unit

Specifications of brake resistors for high frequency

 

(Units: mm)

 

External appearance of FR-ABR

External appearance of FR-ABR

  • * The regenerative brake usage rate should be set to be less than or equal to the allowable brake usage rate in the table.
  • * Depending on the frequency of operation, the temperature of the brake resistor may exceed 300°C, so be careful when installing and dissipating heat.
  • * Do not remove the short-circuit piece between terminals P/+-P1 except when connecting a DC reactor.
  • * MYS type resistors can also be used. However, pay attention to the allowable brake usage rate.
  • * It cannot be used for 0.1K and 0.2K.
Dimensional drawing of FR-ABR

Dimensional drawing of FR-ABR

 

(Units: mm)

 

Brake resistor type nameAllowable brake utilization rateExternal dimensionsResistance value
(Ω)
Approximate weight
(kg)
WW1DH
200 V *1FR-ABR-0.4K10%14050040212000.2
FR-ABR-0.75K10%21550040211000.4
FR-ABR-2.2K10%2405005026600.5
FR-ABR-3.7K10%2155006133400.8
FR-ABR-5.5K10%3355006133251.3
FR-ABR-7.5K10%4005008040202.2
FR-ABR-11K6%40070010050133.5
FR-ABR-15K *36%3007001005018
( × 1/2)
2.4
( × 2)
FR-ABR-22K *26%4007001005013
( × 1/2)
3.3
( × 2)
400 VFR-ABR-H0.4K10%11550040211,2000.2
FR-ABR-H0.75K10%14050040217000.2
FR-ABR-H1.5K10%21550040213500.4
FR-ABR-H2.2K10%24050050262500.5
FR-ABR-H3.7K10%21550061331500.8
FR-ABR-H5.5K10%33550061331101.3
FR-ABR-H7.5K10%4005008040752.2
FR-ABR-H11K6%40070010050523.2
FR-ABR-H15K *46%3007001005018
( × 2)
2.4
( × 2)
FR-ABR-H22K6%4507001005052
( × 2)
3.3
( × 2)
  1. * 1: It can also be connected to a single-phase 100 V class inverter.
  2. * 2: It is shared by 1.5K and 2.2K.
  3. * 3: 15K should be configured with 2 parallel connections of 18 Ω.
  4. * 4: H15K should be configured with 2 parallel connections of 18 Ω. The resistor is labeled FR-ABR-15K. (Same resistor as 200 V class 15K)

Specifications of brake unit

External appearance of FR-BU2

External appearance of FR-BU2

Option to get even greater braking capacity than an external brake resistor.
It can also be connected to an inverter that does not have a built-in brake transistor.
There are 2 types of discharge resistors, so select according to the required braking torque.

Dimensional drawing of FR-BU2-55K, FR-BU2-H7.5K to H75K

Dimensional drawing of FR-BU2-55K, FR-BU2-H7.5K to H75K

 

(Units: mm)

 

Type NameWHD
FR-BU2-1.5K~15K68128132.5
FR-BU2-30K108128129.5
FR-BU2-55K170128142.5
FR-BU2-H30K108128129.5
FR-BU2-H55K, H75K170128142.5
Format FR-BU2-□200 V400 V
1.5K3.7K7.5K15K30K55KH7.5KH30KH55KH75K
Compatible motor capacityThe capacity that can be combined depends on the braking torque and usage rate (% ED).
Connected brake resistorGRZG type, FR-BR, MT-BR5
Multiple (parallel) operationUp to 10 (However, torque that exceeds the overcurrent withstand capacity of the connected inverter cannot be output. )
Approximate weight (kg)0.90.90.90.91.42.00.91.42.02.0

Specifications of resistor unit

External appearance of FR-BR

External appearance of FR-BR

Dimensional drawing of FR-BR

Dimensional drawing of FR-BR

 

(Units: mm)

 

Resistor unit
Type NameWHD
FR-BR-15K170450220
FR-BR-30K340600220
FR-BR-55K480700450
FR-BR-H15K170450220
FR-BR-H30K340600220
FR-BR-H55K480700450

* The maximum temperature rise of the resistor unit is 100°C. Therefore, use a heat-resistant cable (glass cable, etc.) for wiring.

Wiring diagram of brake unit and resistor unit

Wiring diagram

Wiring diagram

  1. * 1: Short-circuit pieces are connected to BUE and SD in the initial state.
  2. * 2: Be sure to connect the inverter terminals (P/+, N/-) and the brake unit (FR-BU2) so that the terminal symbols are the same. Incorrect connection will damage the inverter.
  3. * 3: Do not remove the short-circuit piece between terminals P/+-P1 except when connecting a DC reactor.
  4. * 4: If the power supply is 400 V class, install a step-down transformer.

Combination table of brake unit and resistor unit

Brake unit formatFormat of discharge resistor or resistor unit
FR-BR
200 V
Class
FR-BU2-15KFR-BR-15K
FR-BU2-30KFR-BR-30K
FR-BU2-55KFR-BR-55K
400 V
Class
FR-BU2-H7.5K-
FR-BU2-H15KFR-BR-H15K
FR-BU2-H30KFR-BR-H30K
FR-BU2-H55KFR-BR-H55K
FR-BU2-H75K-

Cautions

*See the catalog for product information other than the listed above.

Part Number
MRS120W40-3.7K
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipApplicable inverter capacity
(kW)
Resistance Value
(Ω)

₹ 4,510.59

1 Piece(s) 10 Day(s) or more 3.740

Loading...

  1. 1
 

Basic Information

Type Brake resistor Compatible Series FREQROL Series Voltage class(V) 200
Dimension (W)(mm) 182 Dimension (D)(mm) 42 Dimension (H)(mm) 20