Relay Number | Operating Method | Alarm Contact | Classification | - | Voltage (V) |
---|---|---|---|---|---|
2 | Non-locking | a | With auxiliary contacts | Model MYA-NA2 | AC 100/110, 200/220 |
DC 24, 100/110 | |||||
Without auxiliary contacts | Model MYA-NA1 | AC 100/110, 200/220 | |||
Lock-in | a | With auxiliary contacts | Model MYA-LA2 | AC 100/110, 200/220 | |
DC 24 | |||||
Without auxiliary contacts | Model MYA-LA1 | AC 100/110, 200/220 | |||
DC 24 | |||||
b | With auxiliary contacts | Model MYA-LB2 | AC 100/110 | ||
DC 24 | |||||
3 | a | No auxiliary contacts (includes circuit for confirming another reset performed after failure recovery) | Model MYA-LA12 | AC 100/110, 200/220 | |
DC 24, 100/110 |
MYA-NA1/MYA-NA2/MYA-LA1/MYA-LA2/MYA-LB2 external appearance
MYA-NA1/MYA-NA2/MYA-LA1/MYA-LA2/MYA-LB2 dimensional drawing, Units: mm
MYA-LA12 external appearance
MYA-LA12 dimensional drawing, Units: mm
With surface connection socket, Units: mm
With rear surface connection socket, Units: mm
Load | Resistive Load | Inductive load (cosφ = 0.4, L/R = 7 ms) |
---|---|---|
Contact Mechanism | Single (Model MY Series) | |
Contact Material | Ag (Model MY Series) | |
Rated Load | 220 V AC 3 A, 24 V DC 3 A | 220 V AC 0.8 A, 24 V DC 1.5 A |
Rated Carry Current | 3 A | |
Max. Contact Voltage Value | 250 V AC, 125 V DC | |
Max. Contact Current Value | 3 A | |
Maximum Switching Capacity Value (Reference Value) | 660 VA 72 W | 176 VA 36 W |
Failure Rate (P Level) (Reference Value*) | 1 V DC 1 mA |
Contact Resistance *1 | 50 mΩ max. | |
---|---|---|
Operating Time *2 | 20 ms max. | |
Recovery Time *2 | 20 ms max. | |
Maximum Switching Frequency | 1,800 operations/hr (rated load) | |
Insulation Resistance *3 | 100 MΩ min. | |
Dielectric Strength | Between Different Poles | 1,000 V AC 50/60 Hz for 1 min |
Vibration | Durability | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) |
Malfunction | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude) | |
Shock | Durability | 1,000 m/s2 |
Malfunction | 200 m/s2 | |
Durability | Mechanical | Minimum of 50,000,000 operations for AC Minimum of 100,000,000 operations for DC (switching frequency 18,000 operations/hr) |
Electrical *4 | 200,000 operations min. (at 1,800 operations/hr under rated load) | |
Ambient Operating Temperature | -10 to +40°C (assuming no icing or condensation) | |
Ambient Operating Humidity | 5 to 85% RH | |
Weight | Approx. 100 to 150 g |
*1. Measurement conditions: 5 V DC, 1 A, voltage drop method.
*2. Measurement conditions: Rated operating voltage applied, not including contact bounce. Ambient temperature: +23°C
*3. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
*4. Ambient temperature conditions: +23°C
Part Number |
---|
MYA-LA12 DC100/110 |
MYA-NA2 DC100/110 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Coil rated voltage (DC) (V) | Coil rated voltage (AC) (V) | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Operating Method | Alarm Contact |
---|---|---|---|---|---|---|---|---|---|---|---|
₹ 3,501.00 | 1 Piece(s) | Available | Same day | 100/110 | - | 50 | 38 | 84.5 | Lock-In | Without a Contact/ Auxiliary Contact | |
₹ 2,757.00 | 1 Piece(s) | Same day | 100/110 | - | 51 | 39 | 65 | Non-Locking | With a Contact/ Auxiliary Contact |
Loading...
Latch function | NA | Terminal shape | Socket / plug-in | Contact rated current (minimum value for AC and DC)(A) | 3 |
---|---|---|---|---|---|
Contact mechanism | Single | Protective Structure | In-Case Type |
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy