Latching Relay MMK

Caution
Product Description
A cost-effective industrial-use relay with a low power consumption.
[Features]
·Type MM power relay with a mechanical lock latching system.
·Mechanically holds the operations.
· Quick operation due to pulse transmitted electrical power.
·Wide operating temperature range from -10°C to +55°C.
·Models compliant with auxiliary power relays (JEC-174D) are also available.
[Applications]
·Ideal for motor and control operation switching.
Latching Relay MMK Series Specifications of OMRON Industrial Relays
| Number Of Poles Industrial Relays | 2 Poles (2 c) | 3 Poles (3 c) | 4 Poles (2 c + 2 a) | |||
|---|---|---|---|---|---|---|
| Format | Rated Voltage (V) | Format | Rated Voltage (V) | Format | Rated Voltage (V) | |
| Standard Type | Model MM2KP | AC 100/(110), 200/(220) | Model MM3KP | DC 100/110 | Model MM4KP | AC 100/(110), 200/(220) |
| DC 24, 100/110 | DC 100/110 | |||||
| DC Load Switching Type | Model MM2XKP | DC 24, 100/110 | Model MM3XKP | DC 100/110 | Model MM4XKP | AC 100/(110) |
| DC 24, 100/110, 125 | ||||||
| Standard Power Auxiliary Relay Type For DC Load Switching | - | - | - | - | Model MM4XKP-JD | DC 100/110 |

MM2KP external appearance of Industrial Relays

MM2(X)KP dimensional outline drawing of Industrial Relays
- *Units: mm
- *When the case-protection plate is attached to the MM2XKP, the width of the relay will be 55 mm max.

Model MM2KP (standard type) terminal layout / internal schematics

Model MM2XKP (DC load switching type) terminal layout / internal schematics

MM4KP external appearance of Industrial Relays

MM3(X)KP/MM4(X)KP dimensional outline drawing of Industrial Relays
- *Units: mm
- *When the case-protection plate is attached to the MM3, 4XKP, the width of the relay will be 73 mm max.

Model MM3KP (standard type) terminal layout / internal schematics

Model MM4KP (standard type) terminal layout / internal schematics
Performance of OMRON Industrial Relays
| Contact Resistance *1 | 50 mΩ max. | |
|---|---|---|
| Set 2 | Time | AC: 30 ms max. DC: 60 ms max. |
| Minimum Pulse Width | Both AC and DC are 100 ms | |
| Reset *2 | Time | 30 ms max. |
| Minimum Pulse Width | Both AC and DC are 100 ms | |
| Maximum Switching Frequency | Mechanical | 1,800 operations/hr |
| Rated Load | 1,800 operations/hr | |
| Insulation Resistance *3 | 100 MΩ min. | |
| Dielectric Strength | Between Coil and Contacts | 2,000 V AC 50/60 Hz for 1 min |
| Between Contacts of Different Polarity | ||
| Between Set And Reset Coil | ||
| Between Contacts of Same Polarity | 1,500 V AC 50/60 Hz for 1 min | |
| Vibration | Durability | 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) |
| Malfunction | 10 to 35 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) | |
| Shock | Durability | 500 m/s2 |
| Malfunction | 50 m/s2 | |
| Durability | Mechanical | 2,500,000 operations min. (at switching frequency of 1,800 operations/hr) |
| Electrical *4 | 500,000 operations min. (at 1,800 operations/hr under rated load) | |
| Failure Rate (P Level) (Reference Value *5) | 5 V DC 10 mA | |
| Ambient Operating Temperature | -10 to +55°C (assuming no icing or condensation) | |
| Ambient Operating Humidity | 5 to 85% RH | |
| Weight | · Standard type of Industrial Relays Model MM2KP approx. 375 g Model MM3KP approx. 550 g Model MM4KP approx. 570 g · DC load switching type Model MM2XKP approx. 380 g Model MM3XKP approx. 555 g Model MM4XKP approx. 580 g | |
- The values given above are initial values of Industrial Relays.
*1. Measurement conditions: 5 V DC, 1 A, voltage drop method.
*2. Measurement conditions: Rated operating voltage applied, not including contact bounce. Ambient temperature: +23°C
*3. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
*4. Ambient temperature: +23°C
*5. This value was measured at a switching frequency of 60 operations/min.
- *See the catalog for dimensional drawings and ratings other than those detailed above.