(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
[Features]
· Simplifies operation of one day schedule control.
· Can select operation weekday (however, only one each of operational weekday and special weekday can be set).
· ON/OFF time schedule setting has 24 steps.
· Compatible with the CE mark.
· UL, CSA standard acquired.
· Remarkably simple handling of bank holidays with holiday function.
· Simplified checking of the program with the test mode function.
· Can deal with urgent schedule changes with the semiautomatic operation.
· Pulse operation enabled as well as Summer time response.
· All functions subject to finger protection.
· A line-up of convention dimension types which are surface or deep mounted.
· Day-to-day operations are possible with the same settings as timer operation.
24-step ON/OFF time schedule settings
Embedded mounted type (mounting adapter Y92F-30 included)
Series H5F-A/-B
Surface mounted type
Series H5F-FA/-FB
Conventional size type
Series H5F-KA/-KB (vertical direction)
Series H5F-KAL (horizontal dimension)
Mounting Method | Embedded Mounting | Surface Mounting | Surface / DIN Rail Mounting (Conventional Type) |
---|---|---|---|
Vertical Direction | |||
Japanese Specification Format | Series H5F-A | Series H5F-FA | Series H5F-KA |
English Specification Format | Series H5F-B |
Model Configuration
Power Supply Voltage | 100 to 240 V AC, 50/60 Hz (Common) |
---|---|
Allowable Voltage Range | 85 to 110% of power supply voltage |
Power Consumption | Approx. 2.4 VA (At 264 V AC) |
Control Output | Contact 1a 250 V AC, 15 A (resistive load) 24 V DC, 10 A (resistive load) Minimum applied load 5 V DC, 100 mA (P level, reference value) |
Operating Temperature Range | −10 to +55°C (No Freezing) |
Storage Temperature Range | −25 to +65°C (No Freezing) |
Ambient Operating Humidity | 35 to 85% |
Case Exterior | Light Gray (Munsell 5Y7/1) |
Rating
Variations In Operating Time | (±0.01% ±0.05 s) or less*1 ±0.01% is the value for the set time interval. | |
---|---|---|
Set Error | ||
Voltage Effect | ||
Temperature Effect | ||
Electromagnetic Interference (According To EN61326-1) | ||
Time Accuracy | ±15 s/month (25°C) | |
Compensation Time For Power Outage | Continuous 5 years or more (25°C), 10 years or more (25°C, power failure ratio 50% or less)*2 (With lithium battery) | |
Insulation Resistance | 100 MΩ or more (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output, between discontinuous contacts) | |
Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) | |
Noise Resistance | Between power supply terminals: ±1.5 kV Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns) | |
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.375 mm, 3 directions, 4 cycles each (8 min/cycle) |
Malfunction | 10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each | |
Shock | Endurance | 300 m/s2, 3 axes each direction, 3 times each |
Malfunction | 100 m/s2, 3 axes each direction, 3 times each | |
Life | Mechanical | 100,000 operations or more (20°C) |
Electrical | 50,000 operations or more (resistive load, 250 V AC, 15 A) 50,000 operations or more (motor load, 250 V AC, 1 HP) 50,000 operations or more (inductive load, 250 V AC, 10 A, cosφ = 0.7) 50,000 operations or more (lamp load, 100 V AC, 100 W) 10,000 operations or more (lamp load, 100 V AC, 300 W) (+20°C) | |
Mass | Approx. 115 g (Series H5F-A), Approx. 160 g (Series H5F-KA), Approx. 130 g (Series H5F-FA) |
Performance
*1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are within (±0.01% ±0.05 s)
*2. Cumulative time of power failure
Safety Standards | cULus (listing): UL508/CSA C22.2 No. 14 EN61010-1 (IEC61010-1): Pollution Degree 2 / Overvoltage Category II A300 PILOT DUTY 1/3HP 120 VAC VDE0106/part10 Product Safety of Electrical Appliance and Material |
---|---|
EMC | (EMI) EN61326-1* Radiation interference field strength EN55011 Group 1 Class A Noise terminal voltage EN55011 Group 1 Class A (EMS) EN61326-1* Electrostatic discharge immunity EN61000-4-2: 4 kV direct, 8 kV atmospheric Field strength immunity EN61000-4-3: 10 V/mAM modulation (80 MHz to 1 GHz, 1.4 to 2 GHz) Conductive noise immunity EN61000-4-6: 10 V (0.15 to 80 MHz) Burst noise immunity EN61000-4-4: 2 kV power supply line, 1 kV output line Surge immunity EN61000-4-5: 1 kV between lines (power supply line, output line), 2 kV between grounds (power supply line, output line) Voltage dip / interruption immunity EN61000-4-11: 0.5 cycles, 100% (rated voltage) Magnetic field strength immunity EN61000-4-8: 30 A/m |
Applicable standards
*Industrial electromagnetic environment (EN/IEC61326-1 Table 2)
Global support
Conforms to the CE mark, all models conform to finger protection standards, so they can be securely used overseas.
Extensive applications
Supports 4 different mounting methods and 24-step ON/OFF operation for a variety of applications.
Usage example
Easily deal with sudden schedule changes using the "holiday function" and "semiautomatic operation."
Part Number |
---|
H5F-FA |
H5F-KA |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Mounting Method | Dimension vertical (mm) | Dimension width (mm) | Dimension depth (mm) |
---|---|---|---|---|---|---|---|---|
₹ 7,888.00 | 1 Piece(s) | Available | Same day | [Other] Surface mounting | 92 | 50 | 42.1 | |
₹ 10,876.94 | 1 Piece(s) | 8 Day(s) | [Other] DIN rail/Surface mount | 101.2 | 50.5 | 60 |
Loading...
Type | Time switch | Display method | Liquid Crystal | Time specifications(s) | 24 h × 7 day (1-min units) |
---|---|---|---|---|---|
Power Supply Voltage | AC-dedicated | Rated power supply voltage(V) | AC 100–240 | Contact Configuration | 1a |
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy