(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
[Features]
· Improved ease of use and convenience; a new standard in timer switches.
· In addition to the weekly 2ch type, 4ch type a year-long series has also been added.
· Operability greatly improved by the use of an independent day-of-the-week key.
· Output of bank holidays and non-weekdays OFF enabled by a simple holiday setting function.
· It can also be set when the power supply is OFF.
· A simple test mode for program checks.
· UL/CSA, acquired the cheaper power law standard, suited to the EMC standard.
Series H5S-□A□ / -□B□ dimensional outline drawing
Series H5S-□A□ / -□B□ panel cut dimensions
Series H5S-□FA□ / -□FB□ dimensional outline drawing
Series H5S-□FA□ / -□FB□ mounting hole processing dimensions (when surface mounting)
When mounting a large terminal cover (sold separately)
When DIN rail is mounted
Type | Weekly 2ch (Series H5S-W□2) | Yearly 2ch (Series H5S-Y□2) | Yearly 4ch (Series H5S-Y□4) | ||
---|---|---|---|---|---|
Power Supply Voltage | · 100 to 240 V AC, 50/60 Hz Common *1 · 24 V DC | ||||
Allowable Voltage Variation Range | 85 to 110% of power supply voltage (AC power supply type) 85 to 120% of power supply voltage (DC power supply type) | ||||
Power Consumption | Approx. 2.9 VA (At 264 V AC, 60 Hz) Approx. 0.8 W (At 28.8 V DC) | Approx. 3.2 VA (At 264 V AC, 60 Hz) Approx. 0.9 W (At 28.8 V DC) | Approx. 3.5 VA (At 264 V AC, 60 Hz) Approx. 1.0 W (At 28.8 V DC) | ||
Control Output | Number Of Circuits | 2 Circuits Independent (2a) | 4 Circuits Independent (4a) | ||
Circuit | Power supply circuit and other (no-voltage) circuit | ||||
Capacity | Resistive load (cosø = 1) | 250 V AC, 15 A *2 | 250 V AC, 3 A | ||
Inductive Load | 250 V AC, 10 A (cosø = 0.7) | 250 V AC, 2 A (cosø = 0.4) | |||
Ambient Operating Temperature | -10 to +55°C (No Freezing Or Condensation) | ||||
Ambient Operating Humidity | 25 to 85% | ||||
Storage Temperature | -25 to +65°C (No Freezing Or Condensation) | ||||
Case Exterior | Light Gray (Munsell 5Y7/1) |
*1. Do not use the inverter output as a power supply. For details, refer to the "Safety Precautions" in the catalog.
* 2 The capacity is 15 A per circuit, but derating of the total current for two circuits is required.
Type | Weekly 2ch (Series H5S-W□2) | Yearly 2ch (Series H5S-Y□2) | Yearly 4ch (Series H5S-Y□4) | |
---|---|---|---|---|
Variations In Operating Time | (±0.01% ±0.05 s) or less*1 ±0.01% is the value for the set time interval. | |||
Set Error | ||||
Voltage Effect | ||||
Temperature Effect | ||||
Cyclic Error | ±15 s/month (25°C) | ±15 s/month (−10 to +45°C), ±20 s/month (+45 to +55°C) | ||
Compensation Time For Power Outage | Continuous 5 years or more (25°C) *2 | |||
Insulation Resistance | 100 MΩ or more (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output, between control outputs, between discontinuous contacts) | |||
Withstand Voltage | 2,950 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part) 2,000 V AC, 50/60 Hz, 1 min (between operation power supply circuit and control output, between control outputs) 1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts) | |||
Noise Resistance | ±1,500 V: between power supply terminals (AC power supply type) ±500 V: between power supply terminals (DC power supply type) Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns) | |||
Vibration | Endurance | 10 to 55 Hz, half amplitude 0.375mm, 3 directions, 2 h each | ||
Malfunction | 10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each | |||
Shock | Endurance | 300 m/s2, 3 axes, 6 directions, 3 times each | ||
Malfunction | 100 m/s2, 3 axes, 6 directions, 3 times each | |||
Life | Mechanical | 100,000 operations or more | ||
Electrical | 50,000 operations or more (resistive load, 250 V AC, 15 A) 50,000 operations or more (resistive load, 30 V DC, 10 A) 50,000 operations or more (inductive load, 250 V AC, 10 A, cosø = 0.7) 50,000 operations or more (motor load, 250 V AC, 1 HP) 50,000 operations or more (lamp load, 100 V AC, 100 W) 10,000 operations or more (lamp load, 100 V AC, 300 W) | 50,000 operations or more (resistive load, 250 V AC, 3 A) 50,000 operations or more (resistive load, 30 V DC, 3 A) | ||
Mass | Approx. 200 g |
*1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are (±0.01% ±0.05 s) or less.
* 2. The compensation time for power outage is the calculated value when the ambient temperature is 25°C during a power outage (storage). Clock function and setting program are backed up by the built-in lithium battery, so the information will be erased when the battery dies. Please understand that the registered contents will be erased when the lithium battery is replaced (circuit board replacement).
Safety Standards | cURus: UL508/CSAC22.2 No. 14 EN60730-2-7: Pollution Degree 2, Overvoltage Category II VDE0106/part100 Product Safety of Electrical Appliance and Material |
---|---|
EMC | (EMI): EN60730-2-7 Radiation interference field strength: EN60730-2-7 (CISPR22 class B) Noise terminal voltage (continuous): EN60730-2-7 (CISPR22 class B) Noise terminal voltage (non-continuous): EN60730-2-7 (CISPR14-1) Harmonic current: EN60730-2-7 (IEC61000-3-2 class A) Voltage variation/flicker: EN60730-2-7 (IEC61000-3-3) (EMS): EN60730-2-7 Electrostatic discharge immunity: EN60730-2-7 (IEC61000-4-2): 6 kV direct, 8 kV atmospheric Field strength immunity: EN60730-2-7 (IEC61000-4-3): 10 V/mAM modulation (80 to 1,000, 1,400 to 2,000 MHz), 10 V/m pulse modulation (900 MHz) Conductive noise immunity: EN60730-2-7 (IEC61000-4-6): 10 V (0.15 to 80 MHz) Burst noise immunity: EN60730-2-7 (IEC61000-4-4): 2 kV (power supply line), 1 kV (control line) Surge immunity: EN60730-2-7 (IEC61000-4-5): 1 kV between lines (power supply line, output line), 2 kV between grounds (power supply line, output line), 0.5 kV between lines (input line), 1 kV between grounds (input line) Voltage dip / interruption immunity: EN60730-2-7 (IEC61000-4-11): 0.5 s cycles, 100% (rated voltage) |
Part Number |
---|
H5S-WA2 |
H5S-WA2D |
H5S-WB2 |
H5S-WB2D |
H5S-WFA2 |
H5S-WFA2D |
H5S-WFB2 |
H5S-YA2-X |
H5S-YA4-X |
H5S-YFA2-X |
H5S-YFA4D-X |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | RoHS | Mounting Method | Time specifications (s) | Power Supply Voltage | Dimension vertical (mm) | Dimension depth (mm) | Rated power supply voltage (V) | Contact Configuration |
---|---|---|---|---|---|---|---|---|---|---|---|---|
₹ 13,481.38 | 1 Piece(s) | 8 Day(s) | - | Panel | Control cycle: 7-Day (1-min units) | AC-dedicated | 72 | 62.7 | AC 100–240 | 2a | ||
₹ 14,899.10 | 1 Piece(s) | 8 Day(s) | - | Panel | Control cycle: 7-Day (1-min units) | Dedicated to DC | 72 | 62.7 | DC24 | 2a | ||
₹ 13,451.87 | 1 Piece(s) | 8 Day(s) | - | Panel | Control cycle: 7-Day (1-min units) | AC-dedicated | 72 | 62.7 | AC 100–240 | 2a | ||
₹ 14,899.10 | 1 Piece(s) | 8 Day(s) | - | Panel | Control cycle: 7-Day (1-min units) | Dedicated to DC | 72 | 62.7 | DC24 | 2a | ||
₹ 13,488.89 | 1 Piece(s) | 8 Day(s) | - | [Other] Surface mounting | Control cycle: 7-Day (1-min units) | AC-dedicated | 96 | 71 | AC 100–240 | 2a | ||
₹ 14,936.13 | 1 Piece(s) | 8 Day(s) | - | [Other] Surface mounting | Control cycle: 7-Day (1-min units) | Dedicated to DC | 96 | 71 | DC24 | 2a | ||
₹ 9,823.00 | 1 Piece(s) | Available | Same day | - | [Other] Surface mounting | Control cycle: 7-Day (1-min units) | AC-dedicated | 96 | 71 | AC 100–240 | 2a | |
₹ 18,308.48 | 1 Piece(s) | 8 Day(s) | - | Panel | Control cycle: year (1-min units) | AC-dedicated | 72 | 62.7 | AC 100–240 | 2a | ||
₹ 29,139.37 | 1 Piece(s) | 8 Day(s) | 10 | Panel | Control cycle: year (1-min units) | AC-dedicated | 72 | 62.7 | AC 100–240 | 4a | ||
₹ 13,423.00 | 1 Piece(s) | Available | Same day | - | [Other] Surface mounting | Control cycle: year (1-min units) | AC-dedicated | 96 | 71 | AC 100–240 | 2a | |
₹ 38,352.90 | 1 Piece(s) | 8 Day(s) or more | - | [Other] Surface mounting | Control cycle: year (1-min units) | Dedicated to DC | 96 | 71 | DC24 | 4a |
Loading...
Type | Time switch | Display method | Liquid Crystal | Output Method | Relay |
---|---|---|---|---|---|
Representative Standard | UL / CSA | Dimension width(mm) | 72 |
How can we improve?
How can we improve?
Thank you for your time.
Your feedback is essential for our continuous improvement
Privacy Policy
Thank you for your cooperation.
Thank you for your time.
Your feedback is essential for our continuous improvement
Please use the inquiry form.
Privacy Policy