Digital Time Switch H5S

Digital Time Switch H5S
  • Volume Discount
You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      9,823₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

Product Description

[Features]
· Improved ease of use and convenience; a new standard in timer switches.
· In addition to the weekly 2ch type, 4ch type a year-long series has also been added.
· Operability greatly improved by the use of an independent day-of-the-week key.
· Output of bank holidays and non-weekdays OFF enabled by a simple holiday setting function.
· It can also be set when the power supply is OFF.
· A simple test mode for program checks.
· UL/CSA, acquired the cheaper power law standard, suited to the EMC standard.

Catalog product information click here

Time Switch Specifications

Series H5S-◯A◯ / -◯B◯ dimensional outline drawing

Series H5S-A / -B dimensional outline drawing

Series H5S-◯A◯ / -◯B◯ panel cut dimensions *1 to 5 mm is appropriate for the mounting panel thickness.

Series H5S-A / -B panel cut dimensions

  • *1 to 5 mm is appropriate for the mounting panel thickness.
Series H5S-◯FA◯ / -◯FB◯ dimensional outline drawing

Series H5S-FA / -FB dimensional outline drawing 

Series H5S-◯FA◯ / -◯FB◯ mounting hole processing dimensions (when surface mounting)

Series H5S-FA / -FB mounting hole processing dimensions (when surface mounting)

When mounting a large terminal cover (sold separately)

When mounting a large terminal cover (sold separately)

  • *Terminal screws are M3.5.
When DIN rail is mounted

When DIN rail is mounted

Rating

TypeWeekly 2ch (Series H5S-W2)Yearly 2ch (Series H5S-Y2)Yearly 4ch (Series H5S-Y4)
Power Supply Voltage· 100 to 240 V AC, 50/60 Hz Common *1
· 24 V DC
Allowable Voltage Variation Range85 to 110% of power supply voltage (AC power supply type)
85 to 120% of power supply voltage (DC power supply type)
Power ConsumptionApprox. 2.9 VA (At 264 V AC, 60 Hz)
Approx. 0.8 W (At 28.8 V DC)
Approx. 3.2 VA (At 264 V AC, 60 Hz)
Approx. 0.9 W (At 28.8 V DC)
Approx. 3.5 VA (At 264 V AC, 60 Hz)
Approx. 1.0 W (At 28.8 V DC)
Control
Output
 
Number Of Circuits2 Circuits Independent (2a)4 Circuits Independent (4a)
CircuitPower supply circuit and other (no-voltage) circuit
CapacityResistive load
(cosø = 1)
250 V AC, 15 A *2250 V AC, 3 A
Inductive Load250 V AC, 10 A (cosø = 0.7)250 V AC, 2 A (cosø = 0.4)
Ambient Operating Temperature-10 to +55°C (No Freezing Or Condensation)
Ambient Operating Humidity25 to 85%
Storage Temperature-25 to +65°C (No Freezing Or Condensation)
Case ExteriorLight Gray (Munsell 5Y7/1)

*1. Do not use the inverter output as a power supply. For details, refer to the "Safety Precautions" in the catalog.
* 2 The capacity is 15 A per circuit, but derating of the total current for two circuits is required.

Performance

TypeWeekly 2ch (Series H5S-W2)Yearly 2ch (Series H5S-Y2)Yearly 4ch (Series H5S-Y4)
Variations In Operating Time(±0.01% ±0.05 s) or less*1
±0.01% is the value for the set time interval.
Set Error
Voltage Effect
Temperature Effect
Cyclic Error±15 s/month (25°C)±15 s/month (−10 to +45°C), ±20 s/month (+45 to +55°C)
Compensation Time For Power OutageContinuous 5 years or more (25°C) *2
Insulation Resistance100 MΩ or more (between conductive part terminal and exposed non-charging metal part, between operation power supply circuit and control output, between control outputs, between discontinuous contacts)
Withstand Voltage2,950 V AC, 50/60 Hz, 1 min (between conductive part terminal and exposed non-charging metal part)
2,000 V AC, 50/60 Hz, 1 min (between operation power supply circuit and control output, between control outputs)
1,000 V AC, 50/60 Hz, 1 min (between discontinuous contacts)
Noise Resistance±1,500 V: between power supply terminals (AC power supply type)
±500 V: between power supply terminals (DC power supply type)
Square-wave noise by noise simulator (pulse width 100 ns/1 μs, rise 1 ns)
VibrationEndurance10 to 55 Hz, half amplitude 0.375mm, 3 directions, 2 h each
Malfunction10 to 55 Hz, half amplitude 0.25mm, 3 directions, 10 min each
ShockEndurance300 m/s2, 3 axes, 6 directions, 3 times each
Malfunction100 m/s2, 3 axes, 6 directions, 3 times each
LifeMechanical100,000 operations or more
Electrical50,000 operations or more (resistive load, 250 V AC, 15 A)
50,000 operations or more (resistive load, 30 V DC, 10 A)
50,000 operations or more (inductive load, 250 V AC, 10 A, cosø = 0.7)
50,000 operations or more (motor load, 250 V AC, 1 HP)
50,000 operations or more (lamp load, 100 V AC, 100 W)
10,000 operations or more (lamp load, 100 V AC, 300 W)
50,000 operations or more (resistive load, 250 V AC, 3 A)
50,000 operations or more (resistive load, 30 V DC, 3 A)
MassApprox. 200 g

*1. Total error including variations in operating time, set errors, and the effects of voltage and temperature are (±0.01% ±0.05 s) or less.
* 2. The compensation time for power outage is the calculated value when the ambient temperature is 25°C during a power outage (storage). Clock function and setting program are backed up by the built-in lithium battery, so the information will be erased when the battery dies. Please understand that the registered contents will be erased when the lithium battery is replaced (circuit board replacement).

Applicable standard

Safety StandardscURus: UL508/CSAC22.2 No. 14
EN60730-2-7: Pollution Degree 2, Overvoltage Category II
VDE0106/part100
Product Safety of Electrical Appliance and Material
EMC(EMI): EN60730-2-7
Radiation interference field strength: EN60730-2-7 (CISPR22 class B)
Noise terminal voltage (continuous): EN60730-2-7 (CISPR22 class B)
Noise terminal voltage (non-continuous): EN60730-2-7 (CISPR14-1)
Harmonic current: EN60730-2-7 (IEC61000-3-2 class A)
Voltage variation/flicker: EN60730-2-7 (IEC61000-3-3)
(EMS): EN60730-2-7
Electrostatic discharge immunity: EN60730-2-7 (IEC61000-4-2): 6 kV direct, 8 kV atmospheric
Field strength immunity: EN60730-2-7 (IEC61000-4-3): 10 V/mAM modulation (80 to 1,000, 1,400 to 2,000 MHz), 10 V/m pulse modulation (900 MHz)
Conductive noise immunity: EN60730-2-7 (IEC61000-4-6): 10 V (0.15 to 80 MHz)
Burst noise immunity: EN60730-2-7 (IEC61000-4-4): 2 kV (power supply line), 1 kV (control line)
Surge immunity: EN60730-2-7 (IEC61000-4-5): 1 kV between lines (power supply line, output line),
2 kV between grounds (power supply line, output line), 0.5 kV between lines (input line), 1 kV between grounds (input line)
Voltage dip / interruption immunity: EN60730-2-7 (IEC61000-4-11): 0.5 s cycles, 100% (rated voltage)
  • *Refer to the catalog for operation tables, operating functions and the selection table for usable accessories.
Part Number
H5S-WFA2
H5S-WFA2D
H5S-WFB2
H5S-YFA2-X
H5S-YFA4D-X
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipRoHSMounting Method Time specifications
(s)
Power Supply Voltage Dimension vertical
(mm)
Dimension depth
(mm)
Rated power supply voltage
(V)
Contact Configuration

₹ 13,488.89

1 Piece(s) 8 Day(s) -[Other] Surface mountingControl cycle: 7-Day (1-min units)AC-dedicated9671AC 100–2402a

₹ 14,936.13

1 Piece(s) 8 Day(s) -[Other] Surface mountingControl cycle: 7-Day (1-min units)Dedicated to DC9671DC242a

₹ 9,823.00

1 Piece(s) Available Same day -[Other] Surface mountingControl cycle: 7-Day (1-min units)AC-dedicated9671AC 100–2402a

₹ 13,423.00

1 Piece(s) Available Same day -[Other] Surface mountingControl cycle: year (1-min units)AC-dedicated9671AC 100–2402a

₹ 38,352.90

1 Piece(s) 8 Day(s) or more -[Other] Surface mountingControl cycle: year (1-min units)Dedicated to DC9671DC244a

Loading...

  1. 1
 

Basic Information

Type Time switch Display method Liquid Crystal Output Method Relay
Representative Standard UL / CSA Dimension width(mm) 72
X
whatsapp-qr whatsapp-icon