(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.

  • Viewed
    Products
  • My
    Components
  • Cart
Recently Viewed Products
X
My Components
X
Cart item(s)
X
Loading...
  • Notice of End of Sales for Economy Series Pneumatic Equipment Category. More information.

Safety Relay G7SA

Safety Relay G7SA
You can add up to 6 items per a category to the compare list.

Part Number :
    • Starting From :
      1,446₹/Unit
  • Order Qty :
  • Total Price :
    ---
  • Days to ship :
    ---

Select part number to Order Now/ Add to Cart

(i)

Caution

  • The delivery date is unstable due to the difficulty in obtaining materials, components, etc. There is no prospect of the next arrival of products for which orders have been suspended.
  • The product images are representative images only. Please refer to the manufacturer's catalog for shape details.

Product Description

A power relay with a high capacity and high dielectric strength that can handle momentary voltage drops.
[Features]
·Wiring work is quicker than conventional screw terminals with the new push-in plus terminal block sockets now available in the product series (Wiring labor-hours are approx. 60% shorter than traditional screw tightening terminals.).
·Relay with forcibly guided contacts (EN/IEC 61810-3 VDE certified).
·Supports the CE marking of machinery (Machine Directive).
·Helps avoid hazardous machine status when used as part of an interlocking circuit.
·Available in 4-position and 6-position.
·Terminal arrangement simplifies PWB pattern design.
· Reinforced insulation between inputs and outputs. Reinforced insulation between some poles of different polarity.
[Applications]
·Helps avoid hazardous machine status when used as part of an interlocking circuit.

Safety Relay Specifications of OMRON Industrial Relays

G7SA external appearance

G7SA external appearance

Industrial Relays, Additional Push-In Plus terminal sockets are used to save wiring work in comparison with traditional screw terminals (wiring time is reduced by 60%* in comparison with traditional screw terminals).
Relay with forcibly guided contacts (EN 50205 / Class A VDE certification)

  • *According to OMRON actual measurement data

Safety Relay Performance of OMRON Industrial Relays

Contact Resistance *1100 mΩ max.
Operating Time *220 ms max.
Response Time *310 ms max.
Recovery Time *220 ms max.
Operating Voltage75% max. relative to rated voltage
Release Voltage10% min. relative to rated voltage
Maximum Switching FrequencyMechanical36,000 operations/hr
Rated Load1,800 operations/hr
Insulation Resistance *41,000 MΩ min.
Dielectric Strength *5 *6Between Coil and Contacts4,000 V AC 50/60 Hz for 1 min
Between Contacts of Different Polarity4,000 V AC 50/60 Hz for 1 min (except for the following)
4 poles: between poles 3 and 4
6 poles: between poles 3 and 5, 4 and 6, and 5 and 6
2,500 V AC 50/60 Hz for 1 min
Between Contacts of Same Polarity1,500 V AC 50/60 Hz for 1 min
Vibration10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Industrial Relays ShockDurability1,000 m/s2
Malfunction100 m/s2
Durability *7Mechanical10,000,000 operations min. (switching frequency 36,000 count/hr)
Electrical100,000 operations min.
(Rated load, switching frequency 1,800 operations/hr)
Inductive Load Switching Performance *8
(IEC60947-5-1)
AC15 240 V AC 2 A
DC13 24 V DC 1 A
Failure Rate (P Level) (Reference Value *9)5 V DC 1 mA
Ambient Operating Temperature *1012 to 48 V DC Specification: -40 to +85°C (assuming no icing or condensation)
110 V DC Specification: -40 to +60°C (assuming no icing or condensation)
Ambient Operating Humidity5 to 85% RH
Industrial Relays Weight4 poles: approx. 22 g
6 poles: approx. 25 g

Note 1: The values given above are initial values of Industrial Relays.
Note 2. Performance characteristic data is measured at a coil temperature of 23°C.
*1. Measurement conditions: 5 V DC, 1 A, voltage drop method.
*2. Measurement conditions: rated voltage operation
Ambient temperature conditions: 23°C
Bounce time not included.
*3. The response time is the time it takes for the a-contacts to open (OFF) after the coil voltage is turned OFF. Contact bounce time is included.
Measurement conditions: rated voltage operation
Ambient temperature conditions: 23°C
*4. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
*5. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals 63-64.
*6. When using a P7SA socket, the dielectric strength between coil contacts/different poles is 2,500 V AC, 50/60 Hz for 1 min. When using Push-In Plus terminal sockets (P7SA-□FND-PU), the dielectric strength between coil contacts aswell as between different poles is 4,000 VAC, 50/60 Hz for 1 min.
*7. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%. For the durability performance to the load, refer to the durability curve data.
*8. Inductive load - AC15: cosø = 0.3, DC13: L/R = 48 ms.
*9. This value is based on a switching frequency of 300 operations/min.
*10. 12 to 48 V DC: When operating between 70 and 85°C, reduce the rated carry current of 6 A by 0.1 A for each degree above 70°C. 110 V DC: When operating between 40 and 60°C, reduce the rated carry current of 6 A by 0.27A for each degree above 40°C.

Safety Relay Dimensional Drawing of OMRON Industrial Relays

Model G7SA-3A1B, Model G7SA-2A2B dimensional drawing

Model G7SA-3A1B, Model G7SA-2A2B dimensional drawing

Model G7SA-3A1B, Model G7SA-2A2B terminal layout / internal schematics

Model G7SA-3A1B, Model G7SA-2A2B terminal layout / internal schematics

PCB processing drawing

PCB processing drawing of Industrial Relays

See the catalog for dimensional drawings for model numbers other than those detailed above.

Part Number
G7SA-2A2B DC12
G7SA-2A2B DC48
G7SA-3A1B DC48
Part NumberPriceMinimum Order Qty.Volume DiscountDays to ShipContact Configuration Contact rated current (minimum value for AC and DC)
(A)
Coil rated voltage (DC)
(V)
Representative Standard Dimension height
(mm)
Protective Structure

₹ 1,446.06

1 Piece(s) 5 Day(s) or more [Other] 2a2b--UL / CSA-Flux resistant shape

₹ 1,446.06

1 Piece(s) 5 Day(s) or more [Other] 2a2b--UL / CSA-Flux resistant shape

₹ 1,446.06

1 Piece(s) 5 Day(s) or more [Other] 3a1b--UL / CSA-Flux Resistant Type

Loading...

  1. 1
 

Basic Information

Application Safety relay Latch function NA Terminal shape For Circuit Boards
Dimension width(mm) 40 Dimension depth(mm) 13
X
whatsapp-qr whatsapp-icon