Loading...

Surface-mount Relay - G6J-Y

Brand :
OMRON

Caution

    Product Description

    An ultra-small and slim type 2-pole signal relay.
    [Features]
    · Suitable for use in high-density mounting applications (5.7 [W] × 10.6 [L] × 9 mm [H])
    · Features a high withstand voltage between the coils and contacts of 1,500 V AC. Also features an impulse withstand voltage of 2.5 kV for 2 × 10 μs (compliant with Telcordia standards.)
    · FCC part 68 (1.5 kV for 10 × 160 μs) compliant for between coil-contacts and between contacts of the same pole.
    · The series also includes single coil latching types, supporting power saving measures.
    · The standard type complies with UL and CSA standards.
    [Applications]
    · Useful for a broad range of applications. Simply mount onto the PCB of communications equipment, OA devices, etc.

    Surface Mount Relay (PCB Terminal Type) Specifications

    Surface Mount Relay G6J-Y: related images

     

    G6J-2P-Y external appearance

    • Units: mm
    • The general dimensional tolerance is ±0.3 mm.

     

    Surface Mount Relay G6J-Y: related images

     

    G6J-2P-Y dimensional outline drawing

    • Units: mm
    • The general dimensional tolerance is ±0.3 mm.

     

    Surface Mount Relay G6J-Y: related images

     

    PCB processing dimensions

    • Units: mm
    • The dimensional tolerance is ±0.1 mm.

     

    Ratings/Performance

    International Standard Certification Rating

    UL/C-UL standards certified type (File No. E41515)

    Number of ContactsOperating Coil RatingContact RatingNumber of Times Tested
    2cModel G6J-2P-Y1 A 30 V DC 40°C
    0.5 A 60 V DC 40°C
    0.3 A 125 V AC 40°C
    6,000

    Ratings

    Operating Coil/Single Stable Type (G6J-2P-Y)

    ItemsRated Current
    (mA)
    Coil Resistance
    (Ω)
    Operating Voltage
    (V)
    Release Voltage
    (V)
    Maximum Allowable Voltage
    (V)
    Power Consumption
    (mW)
    Rated Voltage (V)
    DC528.9173.175% or Less10% or More150%Approx. 140
    1212.3976.8
    249.22,600.5Approx. 230

    *1: The rated current and coil resistance are measured at a coil temperature of 23°C and a tolerance of ±10%.
    Note 2: The operating characteristics are measured at a coil temperature of +3°C.
    *3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.

    Switching Part (Contact Part)

    LoadResistance Load
    Rated Load125 V AC 0.3 A
    30 V DC 1 A
    Rated Conduction Current1 A
    Maximum Contact Voltage Value125 V AC, 110 V DC
    Maximum Contact Current Value1 A

    Performance

    TypeSingle Stable Type
    ModelModel G6J-2P-Y
    Contact Resistance *1100 mΩ or Less
    Operation (Set) Time *23 ms or Less (Approx. 1.6 ms)
    Recovery (Reset) Time *23 ms or Less (Approx. 1.0 ms)
    Minimum Set/Reset Pulse Width-
    Insulation Resistance *31,000 MΩ or More (at 500 V DC)
    Withstand VoltageBetween Coil and Contact1,500 V AC 50/60 Hz 1 min
    Between Contacts of Different Polarities1,000 V AC 50/60 Hz 1 min
    Between Contacts of Same Polarity750 V AC 50/60 Hz 1 min
    Impulse Withstand VoltageBetween Coil and Contact2,500 V 2 × 10 μs
    Between Contacts of Different Polarities1,500 V 10 × 160 μs
    Between Contacts of Same Polarity
    VibrationDurability10 to 55 to 10 Hz, Semi Amplitude 2.5 mm (Double Amplitude 5 mm)
    Malfunction10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm)
    Shock / ImpactDurability1,000 m/s2
    Malfunction750 m/s2
    DurabilityMechanical50,000,000 Times or More (Switching Frequency: 36,000 Times/h)
    Electrical100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h)
    Failure Rate P Level (Reference Value *4)DC 10 mV 10 μA
    Ambient Operating Temperature-40 to +85°C (Assuming No Freezing or Condensation)
    Operating Ambient Humidity5 to 85%RH
    WeightApprox. 1.0 g

    *The above values are the initial default values.

    *1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
    *2. The values within ( ) are the actual values.
    *3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
    *4. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.