(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
[Features]
· Built-in CT, new concept SSR allows for heater disconnection detection and SSR short-circuit malfunction detection.
· Built-in CT, promotes reduction in wiring man-hours.
· Can detect single disconnection in multiple heaters.
· Can detect disconnection in 3-phase heaters.
· Can detect SSR short-circuit malfunctions.
· Abnormality detection level can be easily set by switch.
· Both DIN rail mounting and screw mounting are possible.
· 3 types of input terminals are available: M3 terminal, screwless clamp terminal (removable), and small minus terminal (removable).
· CSA standards, EN standards (TÜV certification) acquired.
· UL standard acquired (model G3PF-2□□B-□□□ series).
G3PF-225B external appearance
G3PF-225B dimensional outline drawing, Units: mm
G3PF-225B dimensional outline drawing, Units: mm
Mounting hole dimensions, Units: mm
G3PF-235B external appearance
G3PF-235B dimensional outline drawing, Units: mm
G3PF-235B dimensional outline drawing, Units: mm
G3PF-235B mounting hole dimensions, Units: mm
Rated Power Supply Voltage | 24 V DC |
---|---|
Operating Voltage Range | 20.4 to 26.4 V DC |
Current Consumption | DC 50 mA max. (at 24 V DC) |
Input Method | Voltage Input |
---|---|
Rated Input Voltage | 12 to 24 V DC |
Operating Input Voltage Range | 9.6 to 26.4 V DC |
Operating Voltage | 9.6 V DC max. |
Release Voltage | 1.0 V DC min. |
Input Current | DC 5 mA max. (with 12 V DC) DC 10 mA max. (with 24 V DC) |
Output OFF Collector Voltage | 30 V DC max. |
---|---|
Maximum Carry Current | 100 mA |
Output Format | NPN open collector (ON when error is detected) |
Minimum Load Current | 0.1 mA |
Model _x000D_ | Model G3PF-225B | Model G3PF-235B |
---|---|---|
Model G3PF-225B-CTB | Model G3PF-235B-CTB | |
Rated Load Voltage | 100 to 240 V AC 50/60 Hz | |
Operating Voltage Range | 75 to 264 V AC 50/60 Hz | |
Rated Carry Current * | 25 A (with 40°C) | 35 A (with 40°C) |
Minimum Load Current | 2 A | |
Inrush Current | 220 A (60 Hz, 1 cycle) | 430 A (60 Hz, 1 cycle) |
* Differs depending on ambient temperature. For details, see the catalog characteristics data "● Rated Load Current—Ambient Temperature."
Format | Model G3PF-225B | Model G3PF-235B | |
---|---|---|---|
Model G3PF-225B-CTB | Model G3PF-235B-CTB | ||
Operating Time | 1/2 of load power source cycle + 1 ms max. | ||
Release Time | 1/2 of load power source cycle + 1 ms max. | ||
Main Circuit | Output On Voltage Drop | 1.6 V (RMS) max. | |
Leakage Current | 10 mA max. (at 200 V AC) | ||
Alarm Output | Output On Voltage Drop | 1.5 V max. | |
Leakage Current | 1 μA max. | ||
Insulation Resistance | 100 MΩ min. (with 500 V ohmmeter) | ||
Dielectric Strength | 2,500 V AC 50/60 Hz for 1 min | ||
Vibration | 10 to 55 to 10 Hz, 0.35-mm single amplitude (0.7-mm double amplitude) | ||
Shock | 294 m/s2 | ||
Storage Temperature | -30 to +70°C (assuming no icing or condensation) | ||
Ambient Operating Temperature | -20 to +60°C (assuming no icing or condensation) | ||
Ambient Operating Humidity | 45 to 85% RH | ||
Weight | Approx. 400 g | Approx. 630 g |
Part Number |
---|
G3PF-225B-CTB DC24 |
G3PF-225B DC24 |
G3PF-235B-CTB DC24 |
G3PF-235B DC24 |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | Terminal shape | Safety standards | Dimension width (mm) | Dimension depth (mm) | Applicable output load (A)/(V) | Function |
---|---|---|---|---|---|---|---|---|---|---|
₹ 13,244.00 | 1 Piece(s) | Available | 6 Day(s) | - | UL / TUV / CSA | 45 | 117 | 2 to 25A/AC100 to 240V | Warning Output 2 Point | |
₹ 6,165.00 | 1 Piece(s) | Available | Same day | Screw Fastening | TUV / CSA | 45 | 110 | 2 to 25A/AC100 to 240V | Warning Output 1 Point | |
₹ 15,948.00 | 1 Piece(s) | 5 Day(s) | - | UL / TUV / CSA | 55 | 137 | 2 to 35A/AC100 to 240V | Warning Output 2 Point | ||
₹ 7,571.00 | 1 Piece(s) | Available | Same day | Screw Fastening | TUV / CSA | 55 | 130 | 2 to 35A/AC100 to 240V | Warning Output 1 Point |
Loading...
Application | SSR | Dimension height(mm) | 100 | Insulation method | Phototriac Coupler |
---|---|---|---|---|---|
Zero cross function | Available | Operation Indicator Lamp | Available | Input rated voltage(V) | DC 12–24 |