Loading...

Latching Relay G7K

Brand :
OMRON

Caution

    Product Description

    Small mechanical lock type latching relay with a manual operation button.
    [Features]
    · Small and lightweight with a height of 71 mm, a width of 42.5 mm and a depth of 48.5 mm with a weight of just 175 g.
    · Quick set and reset response through pulse signals.
    · Gold-plated contacts for high contact reliability.
    · Use OMRON's PTF14A (for LY4 Relays) socket.
    [Applications]
    · Has a set coil and reset coil, and is used for output holding.
    · Features a manual operation button and can perform output and reset tests.

    Latching Relay G7K Specifications

    Latching Relay G7K: related images

    G7K external appearance

    Latching Relay G7K: related images

    G7K dimensional drawing

    Latching Relay G7K: related images

    G7K terminal layout / internal schematics
    The set and reset coils have no coil polarity

    G7K Type

    Contact Configuration2 c, 2 a
    ClassificationFormatRated Voltage (V)
    Standard TypeModel G7K-412SAC 100
    AC 200
    DC 24
    DC 100
    DC 110

    Note: Models are also available with built-in diodes for reverse voltage absorption.

    G7K Rating

    Operating Coil

    Rated Voltage (V)Rated Current (mA)Coil Resistance (Ω)Set
    Voltage (V)
    Reset
    Voltage (V)
    Maximum Allowable
    Voltage (V)
    Power Consumption
    (VA/W)
    50 Hz60 HzOn the Basis of Rated Voltage
    AC10022.720.21,47080% max.80% max.110%
    (115% 3 h)
    Approx. 2
    20011.19.96,340
    DC2436.5660110%
    (130% 3 h)
    Approx. 0.9
    1008.911,300
    1108.413,000

    Note 1. The rated current and coil resistance are measured at a coil temperature of +23°C with tolerances of +15%, -20% for AC rated current and ±15% for DC coil resistance.
    Note 2. The AC coil resistance values are for reference only.
    *The figures for the operating characteristics are for a coil temperature of +23°C.
    Note 4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power voltage, measured at ambient temperature 23°C. There is no continuous allowance.

    Switch

    FormatModel G7K-412S
    LoadResistive LoadInductive load
    (cosφ = 0.4, L/R = 7 ms)
    Contact MechanismSingle
    Contact MaterialAu plating + Ag
    Rated Load220 V AC 3 A, 110 V DC 1 A220 V AC 1 A, 30 V DC 1 A
    Rated Carry Current3 A
    Max. Contact Voltage Value250 V AC, 125 V DC
    Max. Contact Current Value3 A
    Maximum Switching Capacity Value (Reference Value)660 VA 110 W220 VA 30 W

    G7K Performance

    Contact Resistance *150 mΩ max.
    Set *2Time30 ms max.
    Minimum Pulse Width100 ms
    Reset *2Time30 ms max.
    Minimum Pulse Width100 ms
    Maximum Switching FrequencyMechanical1,800 operations/hr
    Rated Load1,800 operations/hr
    Insulation Resistance *3100 MΩ min.
    Dielectric StrengthBetween Contacts of Same Polarity1,500 V AC 50/60 Hz for 1 min
    Between Contacts of Different Polarity2,000 V AC 50/60 Hz for 1 min
    Between Coil and Contacts2,000 V AC 50/60 Hz for 1 min
    Between Set And Reset Coil2,000 V AC 50/60 Hz for 1 min
    VibrationDurability10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
    Malfunction10 to 22 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)
    ShockDurability300 m/s2
    Malfunction30 m/s2
    DurabilityMechanical300,000 operations min. (at switching frequency of 1,800 operations/hr)
    Electrical *4100,000 operations min. (at switching frequency of 1,800 operations/hr)
    Failure Rate (M Level) (Reference Value *5)5 V DC 10 mA
    Ambient Operating Temperature-10 to +55°C (assuming no icing or condensation)
    Ambient Operating Humidity5 to 85% RH
    WeightApprox. 175 g

    Note: The values given above are initial values.

    1. *1. Measurement conditions: 1 V DC, 10 mA, voltage drop method.
    2. *2. Measurement conditions: Rated operating voltage applied, not including contact bounce.
    3. *3. Measured with a 500 V DC ohmmeter at the same places that the dielectric strength was checked.
    4. *4. Ambient temperature conditions: +23°C
    5. *5. This value is based on a switching frequency of 60 operations/min.