Cable for European/North American Standard Supported Equipment

Caution
- The product image is a representative image. Specifications may vary by part number, including shape and color.
Product Description
A cable made of bare soft copper stranded wire insulated with heat resistant PVC. Single-core vinyl insulated cable obtained under multiple standards in North America, Europe and Japan.
[Features]
· Multi-standard cable certified under UL1015 + MTW of North America, H07 V2K of Europe, and HKIV of Japan.
· A high safety product with excellent heat resistance and vertical flame retardance
· Compatible with the HD standard of Europe, UL standard of the US, cUL standard of Canada and HKIV and 60227IEC02 of Japan.
· This product is compatible with "UL Traceability Program / Processed Wires."
[Applications]
· Can be used for internal wiring of semiconductor manufacturing equipment and other equipment mainly for export
· For internal wiring of equipment
|
Dimensional Drawing and Product Specifications

A ULCE-KIV composite standard cable.

GY (green/yellow, straight), 3 lines for grounding.
Product Classification
| Product name | Product Classification | Remarks |
|---|---|---|
| A ULCE-KIV composite standard cable (Cable for internal wiring of electrical devices) | MTW+AWM 1015+AWM I A/B | MTW: UL AWM 1015: UL AWM I A/B: CSA |
| MTW+AWM 1015+AWM I A/B+HKIV | MTW: UL AWM 1015: UL AWM I A/B: CSA HKIV: <PS>E | |
| H07 V2-K+MTW+AWM 1015 +AWM I A/B+60227 IEC 02 | H07 V2-K: CENELEC HD MTW: UL AWM 1015: UL AWM I A/B: CSA 60227 IEC 02: <PS>E |
Product Specifications
| Product Classification | Cross-sectional area | Applicable Standards | Rating | Flame retardancy | |
|---|---|---|---|---|---|
| Voltage | Temperature | ||||
| MTW+AWM 1015+AWM I A/B | 0.5 mm2 (20 AWG) | UL 1063 MTW | 600V | 90°C DRY 60°C WET | VW-1 |
| UL 758 AWM 1015 | 600 V AC or 750 V DC | 105°C | VW-1 | ||
| CSA-C22.2 No.210 | 600V | 105°C | FT-1 | ||
| MTW+AWM 1015+AWM I A/B+HKIV | 0.75 mm2 (18 AWG) 1.0 mm2 (18 AWG) | UL 1063 MTW | 600V | 90°C DRY 60°C WET | VW-1 |
| UL 758 AWM 1015 | 600 V AC or 750 V DC | 105°C | VW-1 | ||
| CSA-C22.2 No.210 | 600V | 105°C | FT-1 | ||
| <PS>E | 600V | 75°C | - F- | ||
| H07 V2-K+MTW+AWM 1015 +AWM I A/B+60227 IEC 02 | 1.5 mm2 (16 AWG) 2.5 mm2 (14 AWG) 4.0 mm2 (12 AWG) 6.0 mm2 (10 AWG) | CENELEC HD 21.7 IEC 60227 | 450 V/750 V | 90°C | IEC60332-1 |
| UL 1063 MTW | 600V | 90°C DRY 60°C WET | VW-1 | ||
| UL 758 AWM 1015 | 600 V AC or 750 V DC | 105°C | VW-1 | ||
| CSA-C22.2 No.210 | 600V | 105°C | FT-1 | ||
| <PS>E J60227 | 450 V/750 V | 70°C | - F- J60332-1 | ||
structure table
| Part number | Cross-sectional area (mm2) | Color | Sales Length | Applicable standards (Applicable) | Conductor | Overall diameter (mm) | Conductor Resistance (20°C) Ω/km | Insulation Resistance MΩkm or more | Insulation resistor temperature conditions | Withstand voltage V/15 min | Allowable current A (30°C) | Approximate Weight (kg/km) | ||||||
| 1 roll (m) | Overall length (m) | UL MTW | UL AWM | PSE 600V | cUL 600V | CE 600V | Configuration (pcs./mm) | Outer diameter (mm) | ||||||||||
| MTW | 0.5* (20 AWG) | BK (Black), R (Red) W (White), BE (Blue) Y (Yellow), O (Orange) GY(Green/Yellow, Straight) | 305 | 10, 50, 100 | Applicable | Applicable | Applicable | 21/0.18 | 1.0 | 2.7 | 30.10 or less | - | - | 2000 | 15 | 12 | ||
| 0.75 * (18 AWG) | Applicable | Applicable | Applicable | Applicable | 34/0.18 | 1.2 | 2.9 | 21.80 or less | 0.05 (50) | 75°C (20°C) | 2500 | 19 | 16 | |||||
| 1.0* (18 AWG) | Applicable | Applicable | Applicable | Applicable | 40/0.18 | 1.3 | 3.0 | 19.50 or less | 19 | 18 | ||||||||
| 1.5* (16 AWG) | 153 | 10, 50 | Applicable | Applicable | Applicable | Applicable | Applicable | 60/0.18 | 1.6 | 3.3 | 13.30 or less | 0.010 | 70°C | 27 | 22 | |||
| 2.5* (14 AWG) | 107 | Applicable | Applicable | Applicable | Applicable | Applicable | 47/0.26 | 2.1 | 3.8 | 7.98 or less | 0.009 | 37 | 34 | |||||
| 4.0* (12 AWG) | BK (Black), R (Red) GY(Green/Yellow, Straight) | Applicable | Applicable | Applicable | Applicable | Applicable | 76/0.26 | 2.6 | 4.3 | 4.95 or less | 0.007 | 50 | 52 | |||||
| 6.0* (10 AWG) | Applicable | Applicable | Applicable | Applicable | Applicable | 112/0.26 | 3.2 | 4.9 | 3.30 or less | 0.006 | 65 | 74 | ||||||
*(AWG--) is only a reference for AWG sizes.
*GY (green/yellow, straight) is a green wire core with a yellow band (approximately 30% retention).
*For the outer diameter size of the cable/wire sheath (outer sheath), please refer to the "overall diameter" item in the table above.
| Operating temperature range | -15 to 105°C |
| Certified standards | ULMTW |
| Bending radius | 8 times the overall diameter (fixed part) |
Structural drawing

Current Reduction Factor
■ MTW standard 90°C dry criteria
| Ambient temperature (°C) | 30 | 40 | 50 | 60 | 70 | 80 |
| Current Reduction Factor | 1.00 | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |
■ MTW standard 60°C wet criteria
| Ambient temperature (°C) | 30 | 40 | 50 |
| Current Reduction Factor | 1.00 | 0.82 | 0.58 |
The allowable current is a calculated value at an ambient temperature of 30°C with a single cable in the air, and is not a guaranteed value.
If the ambient temperature is 30°C or higher, multiply the allowable current by the above current reduction factor.
(Example) Allowable current value for 0.5 mm2 at an ambient temperature of 40°C in a dry state
11 x 0.91 = 10.01 (A)