(!)NOTE : Windows 7 users won’t be able to use some latest features of eCatalog/WOS since Microsoft is ending support for Windows 7 on 14 Jan, 2020. Please upgrade your system for uninterrupted services.
Select part number to Order Now/ Add to Cart
Excellent damping characteristics. Space-saving design. Recommended filter for Mitsubishi Electric Corporation general-purpose AC servo.
Product picture of FTB Series (80A / 100A / 150A)
Code | Leakage Current *2 Upper Row : △-connection Lower Row : Y-connection | Line to Ground Capacitor CY1 (Nominal Value) | Line to Ground Capacitor CY2 (Nominal Value) |
---|---|---|---|
203 | 1.0mA/2.0mA max 0.1mA/0.2mA max | 10,000pF | 10,000pF |
663 | 2.5mA/5.0mA max 0.35mA/0.7mA max | 33,000pF | 33,000pF |
324 | 12mA/24mA max 1.5mA/3.0mA max | 220,000pF | 100,000pF |
355 *1 | 330mA/515mA max 40mA/80mA max | 220,000pF | 3,300,000pF |
*When the line to ground capacitor code is different, the attenuation characteristic is different.
*1 "355" is applied only to "L" type.
*2 Input 250/500V 60Hz
(Only D-connection of "355" is 250/400V 60Hz)
Book type (Space-saving type)
- 2-stage filter High-attenuation (150kHz - 1MHz)
- Selectable leakage current value,Ultra high-attenuation type
"-355-L" for EU (Y type with neutral earth system)
No. | Items | FTB-80-663 | FTB-100-663 | FTB-150-663 |
---|---|---|---|---|
1 | Rated Voltage (V) | AC Three Phase 500 (voltage range:528 max) 50/60Hz | ||
2 | Rated Current (A) | 80 | 100 | 150 |
3 | Test Voltage (Terminal-Mounting Plate) | 2,500 VAC (Cutoff Current = 100mA), 1minute at room temperature and humidity | ||
4 | Isolation Resistance (Terminal-Mounting Plate) | 500 VDC 100MW min at room temperature and humidity | ||
5 | Leakage Current 250/500V 60Hz | 2.5mA/5.0mA max | ||
6 | DC Resistance | 10mΩ max | 8mΩ max | 6mΩ max |
7 | Safety Agency Approval Temperatures | -25 to +85 °C (Refer to Derating Curve) | ||
8 | Operating Temperature | -40 to +85 °C (Refer to Derating Curve) | ||
9 | Operating Humidity | 20 to 95%RH (Non condensing) | ||
10 | Storage Temperature/Humidity | -40 to +85 °C/20 to 95%RH (Non condensing) | ||
11 | Vibration | 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis 12 Impact | ||
12 | Impact | 196.1m/s2 (20G), 11ms. Once each X, Y and Z axis | ||
13 | Safety Agency Approvals | UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC | ||
14 | Case Size (Without Projection) | 100 x 170 x 350 mm (W x H x D) | 100 x 210 x 400 mm (W x H x D) | |
(3.94X6.69X13.78 inches) | (3.94X8.27X15.75 inches) | |||
15 | Weight | 5.3kg max | 7.8kg max |
External view of FTB-50-/FTB-100-
External view of FTB-150-
Part Number |
---|
FTB-80-324-H |
Part Number | Price | Minimum Order Qty. | Volume Discount | Days to Ship | RoHS | Rated Current (A) | D (mm) | H (mm) | Leak current value (mA max) | Special Notes |
---|---|---|---|---|---|---|---|---|---|---|
₹ 72,445.49 | 1 Piece(s) | 14 Day(s) or more | 10 | 80 | 350 | 170 | 24(500V60Hz) | High permeability choke coil part (ultra-low-pass, high-attenuation) |
Loading...
Input Type | Three-Phase | Mounting Method | Fasten With Screws | Wiring Method | Screw Fastening |
---|---|---|---|---|---|
Safety standards | UL / CUL / CSA | W(mm) | 100 | Representative standards (VDE) | Corresponds To |
Representative standards (ENEC) | Corresponds To | 150 kHz to 1 MHz, high attenuation | Corresponds To |