LFA300F Model 300W Single Output

Caution
- [Information for recommended related products]
Cable Clamp with Urethane to Save Space
Dsub Connector Harness (Molded) - The delivery date is unstable due to the difficulty in obtaining materials, components, etc.
Sales of products currently in stock may be temporarily suspended in the future depending on their availability.
Products for which orders have been suspended are not expected to be restocked anytime soon.
Product Description
Wide input voltage, circuit board starter type, a wide variety of variations with models from 10 W to 300 W, 300 W model.
[Features]
·When the remote control is off, the option "-R2" with reduced standby power (1.1 W typ at 200 V AC) is set
·Screw fall prevention mechanism is used for input and output terminal blocks
·High efficiency by adopting synchronous rectification (3.3, 5 V product)
·Harmonic current regulation compliant (Compliant with IEC61000-3-2)
·24 V has achieved natural air cooling 300 W (peak 456 W)
·The option "-SNF" with built-in forced draft fan is set (5 V, 12 V, 24 V)
·Wide input voltage (AC85 to 264 V)
·Power rate improvement
·Mounting compatibility with LGA series (100 V AC input)
·With inrush current prevention circuit, overcurrent and overvoltage protection circuit
·Compliant with various safety standards (L60951-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178-acquired, the Electrical Appliances and Materials Safety Act compliant
·Compatible with SEMI F47 standard
[Applications]
·It can be used for various general-purpose devices
INDEX
Features of LFA300F

LFA300F
Downsizing (28% reduction in floor area compared to the conventional model) same floor area as LGA240 A
- * Product height differs. Please check the specifications for details.
When the remote control is off, the option "-R2" with reduced standby power (1.1 W typ at 200 V AC) is set
Screw fall prevention mechanism is used for input and output terminal blocks
High efficiency by adopting synchronous rectification (3.3, 5 V product)
Harmonic current regulation compliant (Compliant with IEC61000-3-2)
24 V has achieved natural air cooling 300 W (peak 456 W)
The option "-SNF" with built-in forced draft fan is set (5 V, 12 V, 24 V)
Extensive optional parts such as dedicated harness
Compatible with SEMI F47 standard
- * This product uses surface mount components. Please be careful not to give stress such as twisting or impact to the circuit board.
Ordering information of LFA300F

1 Series name
2 Single output
3 Rated output power
4 Full range input
5 Rated output voltage
→6 continues to the right
6 options
C: Coating
G: Low leakage current
H: Peak current compatible (24 V or more)
J: EP (Tyco Electronics) connector (12 V or more)
J1: VH (J.S.T) connector (12 V or more)
R: With remote ON/OFF
R2: With remote control
S: With chassis
SN: With chassis and cover
SNF: With fan (5 V, 12 V, 24 V)
T: Terminal block horizontal type
Y: With potentiometer
Block diagram

Drawing

- * The external shape is different for options. The parts positions without dimensional instructions in the figure are for reference only.
- * Since the surface mount parts are mounted on the back side, please be careful about contact in consideration of vibration.
- * Please use a spacer of 8 mm or more.
- * There are 5 mounting holes in total.
- * Point A, point B, point C, and point D are temperature measurement points.
- * General tolerance: ±1
- * Please use TB2 at 20 A or less per pin.
- * Terminal block tightening torque M4: 1.6 N⋅m (16.9 kgf⋅cm) max
- * Weight: 810 g max (With chassis and cover: 1,270 g max)
- * Circuit board: Glass composite (CEM3)
- * Please check the manufacturer web site or catalog for details of the product.
Product specifications
| — | Item | LFA300F-3R3-TY | LFA300F-5-TY | LFA300F-12-TY | LFA300F-15-TY | LFA300F-24-TY | LFA300F-24-HTY | LFA300F-30-TY | LFA300F-36-TY | LFA300F-48-TY | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Maximum output power [W]*5 | 198 | 300 | 324 | 330 | 336 | 336 (456) | 330 | 338.4 | 336 | ||
| DC output *5 | Natural air cooling | 3.3 V 40 A | 5 V 40 A | 12 V 17 A | 15 V 14 A | 24 V 12.5 A | 24 V 12.5 (19) A | 30 V 10 A | 36 V 8.4 A | 48 V 6.3 A | |
| Forced draft fan | 3.3 V 60 A | 5 V 60 A | 12 V 27 A | 15 V 22 A | 24 V 14 A | 24 V 14 (19) A | 30 V 11 A | 36 V 9.4 A | 48 V 7 A | ||
| Input | Voltage [V] | AC85 to 264 1⌀ (Refer to the section 1.1 and section 3.2 of the instruction manual) *4 | |||||||||
| Current [A] | ACIN 100 V | 2.7 typ (lo = 100%) | 4.1 typ (lo = 100%) | ||||||||
| ACIN 200 V | 1.4 typ (lo = 100%) | 2.0 typ (lo = 100%) | |||||||||
| Frequency [Hz] | 50/60 (47 to 63) | ||||||||||
| Efficiency [%] | ACIN 100 V | 75.0 typ | 79.0 typ | 80.0 typ | 81.5 typ | 85.0 typ | 85.0 typ | 85.5 typ | 85.5 typ | 85.5 typ | |
| ACIN 200 V | 77.0 typ | 82.5 typ | 83.0 typ | 84.5 typ | 88.0 typ | 88.0 typ | 88.0 typ | 88.0 typ | 88.0 typ | ||
| Power rate (lo = 100%) | ACIN 100 V | 0.98 typ | 0.99 typ | ||||||||
| ACIN 200 V | 0.92 typ | 0.95 typ | |||||||||
| Inrush current [A] | ACIN 100 V | 15/30 typ (lo = 100%) (Primary inrush current value / secondary inrush current value) (Re-input interval of 3 seconds or more) | |||||||||
| ACIN 200 V | 30/30 typ (lo = 100%) (Primary inrush current value / secondary inrush current value) (Re-input interval of 3 seconds or more) | ||||||||||
| Leakage current [mA] | 0.45/0.75 max (According to each measurement method of 100 V/240 V AC Input 60 Hz, lo = 100%, IEC60950-1, the Electrical Appliances and Materials Safety Act) | ||||||||||
| Output | Rated voltage [V] | 3.3 | 5 | 12 | 15 | 24 | 24 | 30 | 36 | 48 | |
| Rated current [A]*5 | Natural air cooling | 40 | 40 | 17 | 14 | 12.5 | 12.5 (Peak 19) | 10 | 8.4 | 6.3 | |
| Forced draft fan | 60 | 60 | 27 | 22 | 14 | 14 (Peak 19) | 11 | 9.4 | 7 | ||
| Static input fluctuation [mV]*7 | 20 max | 20 max | 48 max | 60 max | 96 max | 96 max | 144 max | 144 max | 192 max | ||
| Static load fluctuation [mV]*7 | 40 max | 40 max | 100 max | 120 max | 150 max | 150 max | 240 max | 240 max | 240 max | ||
| Ripple [mVp · p] | 0 to +40°C ※2 | 80 max | 80 max | 120 max | 120 max | 120 max | 240 max | 150 max | 150 max | 150 max | |
| -10 to 0°C ※2 | 140 max | 140 max | 160 max | 160 max | 160 max | 320 max | 200 max | 200 max | 200 max | ||
| Ripple noise [mVp · p] | 0 to +40°C ※2 | 120 max | 120 max | 150 max | 150 max | 150 max | 300 max | 250 max | 250 max | 250 max | |
| -10 to 0°C ※2 | 160 max | 160 max | 180 max | 180 max | 180 max | 360 max | 300 max | 300 max | 300 max | ||
| Ambient temperature fluctuation [mV] | 0 to +40°C | 50 max | 50 max | 120 max | 150 max | 240 max | 240 max | 360 max | 360 max | 480 max | |
| -10 to +40°C | 60 max | 60 max | 150 max | 180 max | 290 max | 290 max | 450 max | 450 max | 600 max | ||
| Drift over time [mV]*3 | 20 max | 20 max | 48 max | 60 max | 96 max | 96 max | 144 max | 144 max | 192 max | ||
| Startup Time [ms] | 350 typ (100 V AC Input, lo = 100%) | ||||||||||
| Retention time [ms] | 20 typ (100 V AC Input, lo = 100%) | ||||||||||
| Variable voltage range [V] | 2.85 to 3.63 | 4.50 to 5.50 | 10.80 to 13.20 | 13.50 to 16.50 | 21.60 to 27.50 | 21.60 to 27.50 | 27.00 to 33.00 | 32.40 to 39.60 | 39.60 to 52.80 | ||
| Voltage setting accuracy [V] | 3.30 to 3.40 | 5.00 to 5.15 | 12.00 to 12.48 | 15.00 to 15.60 | 24.00 to 24.96 | 24.00 to 24.96 | 30.00 to 31.20 | 36.00 to 37.44 | 48.00 to 49.92 | ||
| Functions included | Overcurrent protection | It operates at 105% min of rated current (101% min of peak current if there is peak current) and automatically returns | |||||||||
| Overvoltage protection [V] | 4.00 to 5.25 | 5.75 to 7.00 | 13.80 to 16.80 | 17.25 to 21.00 | 27.60 to 33.60 | 27.60 to 33.60 | 34.50 to 42.00 | 41.40 to 50.40 | 55.20 to 67.20 | ||
| Operating indication | N/A | ||||||||||
| Remote sensing | N/A | ||||||||||
| Remote ON/OFF (RC) | Option (External drive power supply required) | ||||||||||
| Dielectric strength | Input - output / RC *6 | 3,000 V AC 1-minute cutoff current = 10 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity) | |||||||||
| Input - FG | 2,000 V AC 1-minute cutoff current = 10 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity) | ||||||||||
| Output / RC - FG *6 | 500 V AC 1-minute cutoff current = 25 mA, 500 V DC 50 MΩ min (Normal temperature, normal humidity) | ||||||||||
| Output - RC *6 | 100 V AC 1-minute cutoff current = 25 mA, 100 V DC 10 MΩ min (Normal temperature, normal humidity) | ||||||||||
| Environment | Operating temperature and humidity *4 | -10 to +70°C, 20 to 90%RH (No condensation) (Refer to the section 3.2 of the instruction manual) | |||||||||
| Storage temperature/humidity | -20 to +75°C, 20 to 90%RH (No condensation) | ||||||||||
| Vibration | 10 to 55 Hz 19.6 m/s^2 (2 G) period 3 minutes X, Y, Z direction 1 hour each | ||||||||||
| Impact | 196.1 m/s^2 (20 G) 11 ms X, Y, Z direction 1 time each | ||||||||||
| Compatible standard | Safety Standard | UL60951-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178-acquired, the Electrical Appliances and Materials Safety Act compliant | |||||||||
| Conducted Emissions | FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B compliant | ||||||||||
| Harmonic current | IEC61000-3-2 (Class A) compliant *8 | ||||||||||
| Structure | External dimensions / weight | 95 × 52.5 × 222 mm (W × H × D)(excluding terminal block) / 810 g max (With chassis and cover: 1,270 g max) | |||||||||
| Cooling method | Natural air cooling / forced draft fan (Refer to the section 3.1 and section 3.2 of the instruction manual) *4 | ||||||||||
- *1 Specifications differ when options are set. Please contact the manufacturer support center for details.
- *2 It is a value on a measuring board with a 22 mF capacitor attached to the point at 150 mm from the output terminal. (By 20 MHz oscilloscope or ripple noise meter (KEISOKUGIKEN: RM-103 equivalent)).
- *3 Drift over time is at ambient temperature of 25°C. It is a change during 30 minutes to 8 hours after applying the input voltage at the rated input/output.
- *4 Output derating is required. Please contact the manufacturer support center for use with DC.
- *5The values in (parentheses) indicate the peak values. Please refrain from continuous use at peak currents.
It may destroy the internal elements.
There is a limit to the peak current (time / duty). - *6 "RC" is applied when adding a remote control (option).
- *7 In case of dynamic fluctuation, the specification may not be satisfied.
- *8 Please contact the manufacturer support center for other classes.
- * Please avoid using it in an overloaded state or outside the specification range, as it may damage the internal elements.
- * Parallel operation is not possible.
- * Derating is required if the chassis and cover are included.
- * Sound noise may be heard from the power supply when used for pulse load.
Lineup and features

Circuit board starter type
| — | Number of outputs | Series name | Release year | Main features | Safety Standard Environmentally friendly | |
|---|---|---|---|---|---|---|
| Circuit board starter type | Single | 1 | GHA | '13 | 3 × 5 inch external shape, compatible with medical electrical equipment, high power density with electric cooling function | UL and C-UL certified product / DEMKO certified product / CE marking compliant product |
| '15 | - SNF: Option with fan | |||||
| '16 | ||||||
| 1 | LMA | '14 | Compatible with medical electrical equipment, peak compatible | UL and C-UL certified product / DEMKO certified product / CE marking compliant product | ||
| 1 | LFP | '12 | Peak current compatible, LEP series compact version | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
| '13 | ||||||
| 1 | LEP | '02 | Peak current compatible | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
| 1 | LFA | '09 | Circuit board starter type general-purpose power supply, LEA series compact version | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
| '10 | ||||||
| SPLFA | '11 | LFA series (with chassis and cover) PSE-acquired product | The Electrical Appliances and Materials Safety Act certified product | |||
| 1 | LEA | '99 | Circuit board starter type general-purpose power supply | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
| 1 | LDA | '94 | Circuit board starter type general-purpose power supply | UL and C-UL certified product / CSA certified product / TUV certified product / CE marking compliant product | ||
| '95 | ||||||
| '97 | UL certified product / C-UL certified product / TUV certified product / CE marking compliant product | |||||
| 1 | LGA | '08 | Input 100 V AC system circuit board starter type general-purpose power supply | UL and C-UL certified product / TUV certified product / CE marking compliant product | ||
| Multi | 2 | LEB | '00 | LEA series 2-output type | UL and C-UL certified product / TUV certified product / CE marking compliant product | |
| 3 | LDC | '94 | LDA series 3-output type | UL and C-UL certified product / CSA certified product / TUV certified product / CE marking compliant product | ||
| '95 | ||||||
| 2 | LB | '92 | Circuit board starter type 2-output power supply, low price has been achieved by limiting performance and functions | — | ||
| Linear type | Single Multi | 1 | G | '75 | 100 V AC system input, linear power supply, ultra-low noise and low ripple | — |
| 2 | GW | '75 | G series 2-output type | — | ||
Development story
By using the same external shape and mounting as those of the 100 V AC (85 to 132 V) LGA series (output power 50 to 240 W), it is easy to replace even if the customer urgently requests 200 V AC compatibility.
In addition, by expanding the lineup with models from 10 to 305 W as a circuit board starter power supply, even if using multiple units, it is possible to arrange them in the same series.