MVVS under 100 V shielded PVC

Brand :
ONAMBA
Caution
Product Description
Shielded general purpose signal cable for low current circuits
[Features]
· Lightweight with a slim overall diameter and excellent flexibility, making it easy to handle during wiring.
· Features a braided shield, providing high noise reduction effect against radiated and external noise, as well as excellent flexibility.
Product Feature Details
- Ultra-fine type
- Instrument cable with braided shield (2 to 4 cores) / multi-core instrument cable with braided shield (5 to 40 cores)
- Bending radius: overall diameter x 8 (fixed part)
Rating
- Temperature: -10 to 60°C
- Voltage: 100 V or less
Features
- Wire core identification is done by color coding for up to 13 cores, and for 14 or more cores, identification is made by line color and combinations, making circuit identification easy.
- The insulator and sheath features environmentally friendly PVC that does not contain lead. (Onamba nominal: Pb Free)
- A drain wire (longitudinally attached) is provided, making terminal processing work easier.
Specifications Table
Multi-core braided shielded instrumentation cable
| Number of wire cores No. of cores | Conductor (AC) Conductor (AC) | Insulator Insulator | Stranded outer diameter mm | Shield thickness mm | Sheath thickness Sheath thickness mm | Overall diameter Finished outer diameter mm | Allowable current (Reference value) Maximum Permissible current (reference value) A | Approximate weight kg/km | |||
| Nominal cross-sectional area Nominal Cross-sectional area mm2 | Configuration No. of wires / Single wire diameter No. of wires / Single wire diameter Wires/mm Wires/mm | Outer diameter mm | Thickness mm | Outer diameter mm | |||||||
| 5C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 3.5 | 0.3 | 1.0 | 6.2 | 3 | 60 |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 4.1 | 0.3 | 1.0 | 6.8 | 4 | 80 | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 4.6 | 0.3 | 1.0 | 7.3 | 5 | 95 | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 6.2 | 0.3 | 1.0 | 8.9 | 8 | 145 | |
| 2 | 37/0.26 | 1.8 | 0.4 | 2.6 | 7.0 | 0.3 | 1.0 | 9.7 | 10 | 185 | |
| 6 to 7C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 3.9 | 0.3 | 1.0 | 6.6 | 3 (3) | 65 (70) |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 4.5 | 0.3 | 1.0 | 7.2 | 4 (4) | 90 (95) | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 5.1 | 0.3 | 1.0 | 7.8 | 5 (5) | 105 (120) | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 6.9 | 0.3 | 1.0 | 9.6 | 7 (7) | 165 (180) | |
| 2 | 37/0.26 | 1.8 | 0.4 | 2.6 | 7.8 | 0.3 | 1.0 | 10.5 | 10 (9) | 205 (230) | |
| 8C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 4.3 | 0.3 | 1.0 | 7.0 | 3 | 75 |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 5.0 | 0.3 | 1.0 | 7.7 | 4 | 100 | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 5.6 | 0.3 | 1.0 | 8.3 | 5 | 130 | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 7.6 | 0.3 | 1.0 | 10.3 | 7 | 195 | |
| 2 | 37/0.26 | 1.8 | 0.4 | 2.6 | 8.6 | 0.3 | 1.0 | 11.3 | 9 | 265 | |
| 10C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 5.2 | 0.3 | 1.0 | 7.9 | 2 | 90 |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 6.0 | 0.3 | 1.0 | 8.7 | 3 | 120 | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 6.8 | 0.3 | 1.0 | 9.5 | 4 | 155 | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 9.2 | 0.3 | 1.0 | 11.9 | 6 | 250 | |
| 2 | 37/0.26 | 1.8 | 0.4 | 2.6 | 10.4 | 0.35 | 1.0 | 13.4 | 8 | 340 | |
| 12C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 5.4 | 0.3 | 1.0 | 8.1 | 2 | 95 |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 6.2 | 0.3 | 1.0 | 8.9 | 3 | 130 | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 7.1 | 0.3 | 1.0 | 9.8 | 4 | 180 | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 9.6 | 0.3 | 1.0 | 12.3 | 6 | 300 | |
| 2 | 37/0.26 | 1.8 | 0.4 | 2.6 | 10.8 | 0.35 | 1.0 | 13.8 | 8 | 380 | |
| 16C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 6.1 | 0.3 | 1.0 | 8.8 | 2 | 125 |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 7.1 | 0.3 | 1.0 | 9.8 | 3 | 170 | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 8.0 | 0.3 | 1.0 | 10.7 | 4 | 225 | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 10.8 | 0.35 | 1.1 | 13.8 | 5 | 365 | |
| 20C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 6.7 | 0.3 | 1.0 | 9.4 | 2 | 145 |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 7.8 | 0.3 | 1.0 | 10.5 | 3 | 200 | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 8.8 | 0.3 | 1.0 | 11.5 | 3 | 260 | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 12.0 | 0.35 | 1.1 | 15.0 | 5 | 455 | |
| 30C | 0.3 | 12/0.18 | 0.7 | 0.3 | 1.3 | 8.3 | 0.3 | 1.0 | 11.0 | 2 | 210 |
| 0.5 | 20/0.18 | 0.9 | 0.3 | 1.5 | 9.6 | 0.3 | 1.0 | 12.3 | 2 | 280 | |
| 0.75 | 30/0.18 | 1.1 | 0.3 | 1.7 | 10.9 | 0.35 | 1.1 | 13.9 | 3 | 375 | |
| 1.25 | 50/0.18 | 1.5 | 0.4 | 2.3 | 14.8 | 0.35 | 1.2 | 18.0 | 4 | 740 | |
Current Reduction Factor
· In the case of ambient temperature| Ambient temperature (°C) | 35 | 40 | 45 | 50 | 55 |
| Current Reduction Factor | 0.91 | 0.82 | 0.71 | 0.58 | 0.41 |
If the ambient temperature is 30°C or higher, multiply the allowable current by the above current reduction factor.
(Example) Allowable current value when the ambient temperature is 40°C with MVVS 0.3 mm2 duplex: 2.0 x 0.82 = 1.64 (A)
Wire Core Identification
Insulator Color
- 2 cores: white, black
- 3 cores: white, black, red
- 4 cores: white, black, red, green
sheath color
GraySurface display

Structure
■ Instrumentation cable with braided shield

No filler is included.
■ Multi-core instrumentation cable with braided shield

Arrangement diagram

Arrangement table

Line marking example
- White/Black: Black line on white background

Instructions / Usage Examples
Applications
Mainly used for wiring electronic devices and measuring instruments under 100 V, especially in locations where noise may be an issue.
Cautions/Prohibitions
Precautions for Use
Do not use in environments that require sliding properties or continuous flexibility, such as cable carriers or robot arms.