Loading...

MVVS under 100 V shielded PVC

Brand :
ONAMBA

Caution

    Product Description

    Shielded general purpose signal cable for low current circuits
    [Features]
    · Lightweight with a slim overall diameter and excellent flexibility, making it easy to handle during wiring.
    · Features a braided shield, providing high noise reduction effect against radiated and external noise, as well as excellent flexibility.

    Product Feature Details

    • Ultra-fine type
    • Instrument cable with braided shield (2 to 4 cores) / multi-core instrument cable with braided shield (5 to 40 cores)
    • Bending radius: overall diameter x 8 (fixed part)

    Rating

    • Temperature: -10 to 60°C
    • Voltage: 100 V or less

    Features

    • Wire core identification is done by color coding for up to 13 cores, and for 14 or more cores, identification is made by line color and combinations, making circuit identification easy.
    • The insulator and sheath features environmentally friendly PVC that does not contain lead. (Onamba nominal: Pb Free)
    • A drain wire (longitudinally attached) is provided, making terminal processing work easier.

    Specifications Table

    Multi-core braided shielded instrumentation cable

    Number of wire cores
    No. of cores
    Conductor (AC)
    Conductor (AC)
    Insulator
    Insulator

    Stranded
    outer diameter
    mm

    Shield
    thickness
    mm
    Sheath thickness
    Sheath
    thickness
    mm
    Overall diameter
    Finished
    outer diameter
    mm
    Allowable current
    (Reference value)
    Maximum
    Permissible current (reference value)
    A
    Approximate
    weight

    kg/km
    Nominal
    cross-sectional area
    Nominal
    Cross-sectional area
    mm2
    Configuration
    No. of wires / Single wire diameter

    No. of wires / Single wire diameter
    Wires/mm
    Wires/mm
    Outer diameter

    mm
    Thickness

    mm
    Outer diameter

    mm
    5C0.312/0.180.70.31.33.50.31.06.2360
    0.520/0.180.90.31.54.10.31.06.8480
    0.7530/0.181.10.31.74.60.31.07.3595
    1.2550/0.181.50.42.36.20.31.08.98145
    237/0.261.80.42.67.00.31.09.710185
    6 to 7C0.312/0.180.70.31.33.90.31.06.63 (3)65 (70)
    0.520/0.180.90.31.54.50.31.07.24 (4)90 (95)
    0.7530/0.181.10.31.75.10.31.07.85 (5)105 (120)
    1.2550/0.181.50.42.36.90.31.09.67 (7)165 (180)
    237/0.261.80.42.67.80.31.010.510 (9)205 (230)
    8C0.312/0.180.70.31.34.30.31.07.0375
    0.520/0.180.90.31.55.00.31.07.74100
    0.7530/0.181.10.31.75.60.31.08.35130
    1.2550/0.181.50.42.37.60.31.010.37195
    237/0.261.80.42.68.60.31.011.39265
    10C0.312/0.180.70.31.35.20.31.07.9290
    0.520/0.180.90.31.56.00.31.08.73120
    0.7530/0.181.10.31.76.80.31.09.54155
    1.2550/0.181.50.42.39.20.31.011.96250
    237/0.261.80.42.610.40.351.013.48340
    12C0.312/0.180.70.31.35.40.31.08.1295
    0.520/0.180.90.31.56.20.31.08.93130
    0.7530/0.181.10.31.77.10.31.09.84180
    1.2550/0.181.50.42.39.60.31.012.36300
    237/0.261.80.42.610.80.351.013.88380
    16C0.312/0.180.70.31.36.10.31.08.82125
    0.520/0.180.90.31.57.10.31.09.83170
    0.7530/0.181.10.31.78.00.31.010.74225
    1.2550/0.181.50.42.310.80.351.113.85365
    20C0.312/0.180.70.31.36.70.31.09.42145
    0.520/0.180.90.31.57.80.31.010.53200
    0.7530/0.181.10.31.78.80.31.011.53260
    1.2550/0.181.50.42.312.00.351.115.05455
    30C0.312/0.180.70.31.38.30.31.011.02210
    0.520/0.180.90.31.59.60.31.012.32280
    0.7530/0.181.10.31.710.90.351.113.93375
    1.2550/0.181.50.42.314.80.351.218.04740
    The allowable current is a reference value calculated based on JCS No. 0168-1. (Under ambient temperature 30°C, with a single wire in air)

    Current Reduction Factor

    · In the case of ambient temperature
    Ambient temperature (°C)3540455055
    Current Reduction Factor0.910.820.710.580.41
    The allowable current is a calculated value at an ambient temperature of 30°C with a single cable in the air, and is not a guaranteed value.
    If the ambient temperature is 30°C or higher, multiply the allowable current by the above current reduction factor.
    (Example) Allowable current value when the ambient temperature is 40°C with MVVS 0.3 mm2 duplex: 2.0 x 0.82 = 1.64 (A)

    Wire Core Identification

    Insulator Color

    • 2 cores: white, black
    • 3 cores: white, black, red
    • 4 cores: white, black, red, green

    sheath color

    Gray

    Surface display

    MVVS under 100 V shielded PVC surface marking

    Structure

    ■ Instrumentation cable with braided shield

    MVVS under 100 V shielded PVC structural diagram 1

    No filler is included.

     

    ■ Multi-core instrumentation cable with braided shield

    MVVS less than 100 V shielded PVC Structural Drawing2

    Arrangement diagram

    MVVS less than 100 V shielded PVC Wiring Diagram

    Arrangement table

    MVVS less than 100 V shielded PVC Wiring Table
     
    Line marking example
    • White/Black: Black line on white background
    MVVS less than 100 V shielded PVC Line Marking Example
     
     
     

    Instructions / Usage Examples

    Applications

    Mainly used for wiring electronic devices and measuring instruments under 100 V, especially in locations where noise may be an issue.

    Cautions/Prohibitions

    Precautions for Use

    Do not use in environments that require sliding properties or continuous flexibility, such as cable carriers or robot arms.

    MVVS-2SQ-2-2 | MVVS under 100 V shielded PVC | ONAMBA | MISUMI India