Thermac NEO temperature controller (digital controller) [E5*N-H/E5*N-HT]

Brand :
OMRON

Caution

    Product Description

    Thermac NEO series, one of the best-selling temperature controller, from model selection to operation and maintenance.
    A high-performance type that responds to higher-speed, higher-accuracy temperature and process control, and a program type that expands the range of compatible applications are also available.

    Drawing

    E5CN-H type

    Thermac NEO temperature controller (digital controller) [E5□N-H/E5□N-HT] E5CN-H type external shape figure

    note: Terminal unit cannot be removed.

     

    Product Specification

    Name of each part

    E5CN-H type

    Thermac NEO temperature controller (digital controller) [E5□N-H/E5□N-HT] E5CN-H type parts identification figure

     

    Rating / Performance

    E5CN-H type rating

    Power supply voltageType without D power supply voltage: AC100 to 240 V 50/60 Hz
    Type with D power supply voltage: 24 V AC 50/60 Hz / 24 V DC
    Allowable Voltage Fluctuation Range85 to 110% of power supply voltage
    Power consumptionWhen using AC100–240 V: 8.5 VA (Max.) (3.0 VA for model E5CN-HR2 at 100 V AC)
    When using AC/24 V DC: 5.5 VA (24 V AC) / 3.5 W (24 V DC) (Max.) (2.7 VA for model E5CN-HR2D at 24 V AC)
    Sensor inputSelectable from the following (fully multi input).
    Thermocouple: K, J, T, E, L, U, N, R, S, B, W, PLII
    Platinum resistance thermometer: Pt100, JPt100
    Current input: 4 to 20 mA, 0 to 20 mA
    Voltage input: 1 to 5 V, 0 to 5 V, 0 to 10 V
    Input impedanceCurrent input: 150 Ω or less, voltage input: 1 MΩ or more (When connecting model ES2-HB-N, please use a 1:1 connection.)
    Control methodON/OFF or 2-degree-of-freedom PID (with auto-tuning)
    Control outputrelay output1a 250 V AC 3 A (resistive load) electrical lifespan: 100,000 cycles minimum applicable load: 5 V 10 mA
    Voltage output
    (for SSR drive)
    output voltage 12 V DC ±15% (PNP) Max. load current 21 mA, with short circuit protection circuit
    Current outputDC 4–20 mA/DC 0–20 mA load 600 Ω or less resolution approx. 10,000*
    Linear voltage outputDC 0–10 V (load 1 kΩ or more) Resolution: approx. 10,000
    Auxiliary outputNumber of contactsMax. 2 contacts
    Output specificationsRelay output 1a 250 V AC 3 A (resistive load) Electrical lifespan: 100,000 cycles Minimum applicable load: 5 V 10 mA
    Event inputNumber of contactsMax. 2 points (depending on model: only for types with event input B)
    External contact
    input specifications
    For contact input: ON: 1 kΩ or less OFF: 100 kΩ or more
    For non-contact input: ON: residual voltage 1.5 V or less OFF: leakage current 0.1 mA or less
    Output current: approx. 7 mA (per contact)
    Simple CalculationNumber of Calculation FormulasMax. 8 (can be combined via internal auxiliary relays)
    Calculation· Logical operation: Any one of the following four patterns can be selected. Each contact can be inverted.
    (A and B) or (C and D), (A or C) and (B or D), A or B or C or D, A and B and C and D (A, B, C, and D are the four input points).
    · Delay: On-delay or off-delay can be applied to the above logic operation results. Setting time: 0–9999 seconds or 0–9999 minutes
    · Output inversion: Supported
    Output1 internal auxiliary relay per calculation formula
    Assignment of internal auxiliary
    relays
    Up to 8 internal auxiliary relays (simple calculation results) can be assigned as follows:
    Event input operation, auxiliary output, or control output
    transfer outputNumber of contactsMaximum 1 point (depending on model: type with transfer output F)
    Output specificationsCurrent output: DC 4–20 mA Load: 600 Ω or less Resolution: approx. 10,000 at 4–20 mA
    RSP inputNot Included
    Setting MethodDigital setting with front keys
    Display Type11-segment digital display and single-point light display (7-segment display also available) Character height PV: 11 mm, SV: 6.5 mm
    Bank Switching functionIncluded (Number of banks: 8)
    Local SP, alarm set values, PID group No. (PID constants, upper/lower limits for manipulated variable, etc.)
    Other functionsManual output, heating/cooling control, loop break alarm function, SP lamp, alarm function, heater disconnection detection function (including SSR failure and heater overcurrent detection function), 40% AT, 100% AT, manipulated variable limit, input digital filter, self-tuning,
    temperature input correction, run/stop, protect, control output ON/OFF count function, square root calculation function, manipulated variable rate-of-change limit,
    PV/SV status display function, simple program function, automatic adjustment of cooling coefficient, etc.
    Operating ambient temperature-10 to +55°C (no condensation or freezing) / For 3-year warranty: -10 to +50°C
    Operating Ambient HumidityRelative humidity 25 to 85%
    Storage temperature-25 to +65°C (no condensation or freezing)

    *For current output type, control output 1 can also be used as a transmission output.

     

    E5CN-H Type Performance

    Indication AccuracyThermocouple: (±0.1% of indicated value or ±1°C, whichever is greater) within ±1 digit*1
    Platinum resistance thermometer: (±0.1% of indicated value or ±0.5°C, whichever is greater) within ±1 digit
    analog input: +/-0.1%FS +/-1 digit or less
    CT input: +/-5%FS +/-1 digit or less
    Transmission output accuracyWithin +/-0.3%FS
    Effect by Temperature*2Thermocouple input (R, S, B, W, PLII): (the greater of +/-1%PV or +/-10°C) +/-1 digit or less
    Other thermocouple input: (the greater of +/-1%PV or +/-4°C) +/-1 digit or less*3
    Platinum resistance thermometer input: (the greater of +/-1%PV or +/-2°C) +/-1 digit or less
    analog input: (±1%FS) ±1 digit or less
    Effect of voltage*2
    Effect of electromagnetic interference
    (according to EN61326-1)
    Input sampling period60 ms
    Control sensitivityTemperature input: 0.1 to 3240.0°C or°F (in 0.1°C or°F increments)
    analog input: 0.01 to 99.99%FS (0.01%FS increments)
    Proportional Band (P)Temperature input: 0.1 to 3240.0°C or°F (in 0.1°C or°F increments)
    analog input: 0.1 to 999.9%FS (0.1%FS increments)
    Integration Time (I)0.0 to 3240.0 s (0.1 s unit)
    Derivative Time (D)0.0 to 3240.0 s (0.1 s unit)
    Control Cycle0.5, 1 to 99 s (1 s increments)
    Manual reset value0.0 to 100.0% (0.1% increments)
    Alarm setting range-19999 to 32400 (Decimal point position depends on input type)
    Effect of signal source resistanceThermocouple: 0.1°C/Ω or less (100 Ω or less), Platinum resistance thermometer: 0.1°C/Ω or less (10 Ω or less)
    Insulation resistance20 MΩ or more (500 V DC insulation resistance tester)
    Withstand voltage2,300 V AC 50 or 60 Hz 1 min (different-pole live parts terminals)
    VibrationMalfunction10 to 55 Hz, 20 m/s2, 10 min in 3-axis directions
    Endurance10 to 55 Hz, 0.75 mm single amplitude, 2 hr in 3-axis directions
    ImpactMalfunction100 m/s2, 3-axis directions, 3 times each
    Endurance300 m/s2, 3-axis directions, 3 times each
    Weightmain body: approx. 150 g installation: approx. 10 g
    Protective StructureFront: IP66, rear case: IP20, terminal: IP00
    Memory ProtectionNon-volatile memory (write cycles: 1,000,000 times)
    Setting ToolCX-Thermo Ver.4.0 or higher
    Port for Setting ToolBottom surface of E5CN-H: Connect between the PC-side USB port and the bottom surface port of E5CN-H using the USB-serial conversion cable E58-CIFQ1.
    *4
    StandardCertification StandardsUL61010-1, CSA C22.2 No.1010-1
    Applicable standardsEN61010-1 (IEC61010-1): Pollution degree 2, overvoltage category II, Lloyd's standard*5
    EMC DirectiveEMI EN61326-1 *6
    Radiated disturbance electric field strength EN55011 Group 1 class A
    Terminal noise voltage EN55011 Group 1 class A
    EMS EN61326-1 *6
    Electrostatic Discharge Immunity EN61000-4-2
    Electromagnetic Field Strength Immunity EN61000-4-3
    Burst Noise Immunity EN61000-4-4
    Conducted Disturbance Immunity EN61000-4-6
    Surge immunity EN61000-4-5
    Power supply frequency magnetic field immunity EN61000-4-8
    Voltage dip/interruption immunity EN61000-4-11

    *1. ±2°C ±1 digit or less for K (-200 to 1300°C range), T, N at -100°C or less, and U, L. No regulations for B of 400°C or less. ±3°C or less for B of 400 to 800°C.
    +/-3°C +/-1 digit or less for R and S of 200°C or less. W: (+/-0.3% of PV or +/-3°C, whichever is larger) +/-1 digit or less.
    PLII: (+/-0.3% of PV or +/-2°C, whichever is larger) +/-1 digit or less.
    *2. Conditions: Ambient temperature: -10°C to 23°C to 55°C Voltage range: -15% to +10% of rated voltage
    *3. For K sensors, below -100°C: within ±10°C
    *4. Simultaneous use of external serial communication (RS-232C or RS-485) and configuration tool cable communication is possible
    *5. For compliance with Lloyd's standards, please refer to page 144 of the digital catalog, "Compliance with Marine Standards."
    *6. Industrial electromagnetic environment (EN/IEC61326-1 Table 2)

     